Multiquip operation manual DCA-45SSIU3 60 Hz -TRAILER Maintenance, Trailer Maintenance

Page 40

DCA-45SSIU3 (60 Hz) —TRAILER MAINTENANCE

Trailer Maintenance

This section is intended to provide the user with generic trailer service and maintenance information.The service and maintenance guidelines referenced in this section refer to a wide range of trailers.

Remember periodic inspection of the trailer will ensure safe towing of the generator and will prevent personal injury and damage to the equipment.

The definitions below describe some of the major components of a typical trailer that would be used with the DCA-45SSIU3 WhisperwattGenerator.

1.Fuel Cell - Provides an adequate amount of fuel for the equipment in use. Fuel cells must be empty when trans- porting equipment.

2.Braking System - System employed in stopping the trailer. Typical braking systems are electric, surge, hy- draulic, hydraulic-surge and air.

3.GVWR- Gross Vehicle Weight Rating (GVWR) is the maximum number of pounds the trailer can carry, in- cluding the fuel cell (empty).

4.Frame Length - Measurement is from the ball hitch to the rear bumper (reflector).

5.Frame Width - Measurement is from fender to fender

6.Jack Stand - Trailer support device with maximum pound requirement from the tongue of the trailer.

7.Coupler - Type of hitch used on the trailer for towing.

8.Tire Size - Indicates the diameter of the tire in inches (10,12,14, etc.), and the width in millimeters (175,185,205, etc.). The tire diameter must match the diameter of the tire rim.

9.Tire Ply - The tire ply (layers) number is rated in letters; 2-ply,4-ply,6-ply, etc.

10.Wheel Hub - The wheel hub is connected to the trailer’s axle.

11.Tire Rim - Tires mounted on a tire rim. The tire rim must match the size of the tire.

12.Lug Nuts - Used to secure the wheel to the wheel hub. Always use a torque wrench to tighten down the lug nuts. See Table 18 and Figure 58 for lug nut tightening and sequence.

13.Axle - Indicates the maximum weight the axle can sup- port in pounds, and the diameter of the axle expressed in inches. Please note that some trailers have a double axle. This will be shown as 2-6000 lbs., meaning two axles with a total weight capacity of 6000 pounds.

14.Suspension - Protects the trailer chassis from shocks transmitted through the wheels. Types of suspension used are leaf, Q-flex, and air ride.

15.Electrical - Electrical connectors (looms) are provided with the trailer so the brake lights and turn signals can be connected to the towing vehicle.

16.Application - Indicates which units can be employed on a particular trailer.

PAGE 40 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV. #0 (11/30/05)

Image 40
Contents Parts List NO. M1870300904 Model DCA-45SSIU3Page Heres HOW to GET Help Wilmington Ave Carson, CADCA-45SSIU3 60 Hz Table of Contents Isuzu BB4JG1T EngineDCA-45SSIU3 60 Hz Parts Ordering Procedures When ordering parts Please supply the following informationDCA-45SSIU3 60 Hz Specifications DCA-45SSIU3 60 Hz Dimensions TOP, Side and Front DimensionsDCA-45SSIU3 60 Hz Safety Message Alert Symbols Injury to yourself and othersDCA-45SSIU3 60 Hz Safety Message Alert Symbols This generator, other property, orDCA-45SSIU3 60 Hz Rules for Safe Operation General SafetyDrugs or alcohol DCA-45SSIU3 60 Hz Rules for Safe Operation Electrical SafetyGenerator Grounding Maintenance Safety Battery SafetyTowing &Transporting Safety EmergenciesDCA-45SSIU3 60 Hz Generator Decals Generator DecalsDCA-45SSIU3 60 Hz Generator Decals DCA-45SSIU3 60 Hz Installation DCA-45SSIU3 60 Hz Installation Outdoor InstallationIndoor Installation When connecting the generatorDCA-45SSIU3 60 Hz General Information Engine Operating PanelGenerator Control Panel Output Terminal PanelDCA-45SSIU3 60 Hz Major Components Generator Major ComponentsAdjustment of the generator’s output voltage Ammeter phase-selector switchDCA-45SSIU3 60 Hz Generator Control Panel Hertz Hz. Normally 60 HzDCA-45SSIU3 60 Hz Engine Operating Panel DCA-45SSIU3 60 Hz Output Terminal Panel Familiarization Output Terminal FamiliarizationDCA-45SSIU3 60 Hz Output Terminal Panel Familiarization F.C.I. Receptacle 120VAC Gfci ReceptaclesConnecting Loads Blower FanSingle Phase Load Three Phase LoadDCA-45SSIU3 60 Hz Load Application Motors and motor-drivenVoltage Selector Switch DCA-45SSIU3 60 Hz Generator OutputsGenerator OutputVoltages Generator AmperageDCA-45SSIU3 60 Hz Gauge Reading How to Read the OutputTerminal GaugesReading Amperage Three-Phase Position DCA-45SSIU3 60 Hz Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø 240/139 Output Terminal Lug VoltagesDCA-45SSIU3 60 Hz Output Terminal Panel Connections 3Ø 480/277 Output Terminal Lug Voltages1Ø 240V/120V Output Terminal Lug Voltages Output Terminal LugsDCA-45SSIU3 60 Hz PRE-SETUP Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure DCA-45SSIU3 60 Hz PRE-SETUPRefueling Cleaning the Radiator Air Cleaner Fan Belt TensionOperation FreezingWeather Must be less than 50%Battery Battery Cable InstallationWhen connecting battery do the following WiringDCA-45SSIU3 60 Hz Generator START-UP Procedure Before StartingEngines exhaust contains harmful emissions Direct exhaust away from nearby personnelFrequency Meter Hz Turn the ignition switch key to the Stop position DCA-45SSIU3 60 Hz GEN. START-UP PROCEDURE/SHUTDOWNRemove all loads from the generator DCA-45SSIU3 60 Hz Maintenance Cleaning the Fuel Strainer Air RemovalCheck Oil Level Replacing Oil FilterDCA-45SSIU3 60 Hz Maintenance To ensure adequate startingDCA-45SSIU3 60 Hz -TRAILER Maintenance Trailer MaintenanceDCA-45SSIU3 60 Hz -TRAILER Maintenance Brake AdjustmentBrakes Check the wheel and drum for free rotationTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Lug Nut Torque Requirements DCA-45SSIU3 60 Hz -TRAILER MaintenanceStart all wheel lug nuts by hand DCA-45SSIU3 60 Hz -TRAILER Wiring Diagram Trailer/Towing Vehicle Wiring DiagramDCA-45SSIU3 60 Hz Generatorwiring Diagram Generator Wiring DiagramDCA-45SSIU3 60 Hz Enginewiring Diagram DCA-45SSIU3 60 Hz -TROUBLESHOOTING Generator Generator TroubleshootingDCA-45SSIU3 60 Hz -TROUBLESHOOTING Engine Engine TroubleshootingDCA-45SSIU3 60 Hz -TROUBLESHOOTING Engine Sample Parts List DCA-45SSIU3 60 Hz Explanation of Code in Remarks ColumnPart number on this Suggested Spare Parts list DCA-45SSIU3 60 Hz Suggested Spare PartsDCA-45SSIU3 60 Hz Generator Assy B3110100202 80510700030010310035 0042510000DCA-45SSIU3 60 Hz Control BOX Assy DCA-45SSIU3 60 Hz Control BOX Assy DCA-45SSIU3 60 Hz Engine & Radiator Assy M1923200054 89704970810605000048 0030010000DCA-45SSIU3 60 Hz Engine & Radiator Assy 0150000018 01999007000605515106 M9300000003DCA-45SSIU3 60 Hz Outputterminal Assy Output Terminal AssyM1230700103 M9220100204M9220100104 0039310000DCA-45SSIU3 60 Hz Engine Operating Panel Assy 8970444180 89440249800602103092 2A# 0601810245DCA-45SSIU3 60 Hz Battery Assy 0602220187 627MFDM9310500014 M9103000304DCA-45SSIU3 60 Hz Muffler Assy M1330100703 0016910025M1333001903 8943690210DCA-45SSIU3 60 Hz Fuel Tank Assy M1363001602 0605505070M1363200104 M9310500104DCA-45SSIU3 60 Hz Enclosure Assy Enclosure AssyM1413002902 M1413400004M1423001902 M1493106703DCA-45SSIU3 60 Hz Enclosure Assy M9310000103 M148360020432-1 0016908020 M1453200602DCA-45SSIU3 60 Hz Rubber Seals Assy 0228901370 02292006600228900620 0228900940DCA-45SSIU3 60 Hz Nameplate and Decals Assy M1550000204 M1550001304M1550002003 M1550002103Terms and Conditions of Sale Parts Page Your Local Dealer is

DCA-45SSIU3 specifications

The Multiquip DCA-45SSIU3 is a robust and versatile diesel generator designed to provide reliable power for various applications, making it an essential piece of equipment for construction sites, events, and emergency backup. This generator is renowned for its efficiency, durability, and user-friendly design, catering to a wide range of power needs while ensuring optimal performance.

One of the standout features of the DCA-45SSIU3 is its powerful 45 kVA output. This generator is powered by a reliable and fuel-efficient Yanmar diesel engine, which not only delivers consistent power but also ensures lower emissions, making it an environmentally friendly choice for power generation. With its high fuel efficiency, operators can expect longer run times between refuels, reducing downtime and increasing productivity on the job site.

The DCA-45SSIU3 boasts a compact and mobile design, equipped with a durable steel frame and a weather-resistant enclosure. This ensures that the generator can withstand harsh outdoor conditions while providing easy access for maintenance and operation. Its built-in forklift channels and lifting eyes enhance its portability, allowing for simple relocation to different job sites.

This generator is equipped with advanced technologies that enhance its performance and safety. The intuitive control panel features easy-to-read gauges and indicators for monitoring performance. Users can quickly access essential functions, including start/stop controls and circuit breaker protections, which safeguard the generator from overloads. Additionally, its automatic voltage regulation delivers stable power, ensuring that sensitive electronic equipment runs smoothly without risk of damage.

The DCA-45SSIU3 also includes a fuel tank designed for extended operation, with a capacity that provides significant hours of runtime. This feature is complemented by an efficient cooling system that maintains optimal engine temperatures, ensuring reliability even during prolonged usage.

In summary, the Multiquip DCA-45SSIU3 is a powerful and dependable generator that meets the demands of diverse applications. Its robust design, combined with advanced features and efficiency, makes it an ideal choice for contractors, event planners, and anyone needing reliable backup power. With a reputation for performance and longevity, this generator stands out in the competitive market of portable power solutions.