Multiquip DCA-220SSJ operation manual Towing &Transporting Safety, Emergencies

Page 13

DCA-220SSJ/SSJU — RULES FOR SAFE OPERATION

Towing &Transporting Safety

To reduce the possibility of an accident while transporting the generator on public roads, always make sure the trailer that supports the generator and the towing vehicle are in good operating condition and both units are mechanically sound.

The following list of safety precautions should be followed when towing your generator:

CAUTION - FOLLOWTOWING REGULATIONS

Check with your local county or state safety towing regulations, in addition to meeting Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

ALWAYS shutdown engine before transporting.

Tighten both fuel tank caps securely.

If generator is mounted on a trailer, make sure trailer complies with all local and state safety transportation laws. Follow the listed Towing & Transporting Safety guidelines for basic towing techniques.

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer "gross vehicle weight rating.”

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a "Safety Chain".

ALWAYS attach trailer’s safety chains to towing vehicle properly.

ALWAYS make sure the vehicle and trailer directional, backup, brake, and trailer lights are connected and working properly.

DOT Requirements include the following:

Connect and test electric brake operation.

Secure portable power cables in cable tray with tie wraps.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place chock blocks underneath wheel to prevent rolling, while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

Avoid sudden stops and starts.This can cause skidding, or jack-knifing. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when transporting.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Place support blocks underneath the trailer’s bumper to prevent tipping, while parked.

Avoid sharp turns to prevent rolling.

DO NOT transport generator with fuel in tank.

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest and first aid kit.

ALWAYS know the location of the nearest phone or keep a phone on the job site, in case of emergencies.

ALWAYS have easy access to the phone numbers of the nearest Ambulance, Doctor and Fire Department. This information will be invaluable in the case of an emergency.

DCA-220SSJ/SSJU— OPERATION AND PARTS MANUAL — REV. #1 (01/06/09) — PAGE 13

Image 13
Contents Models DCA-220SSJ DCA-220SSJU Parts List NO. C1870300404Diesel engine exhaust and some Proposition 65WARNINGDCA-220SSJ/SSJU- Operation and Parts Manual REV. #1 01/06/09 Table of Contents Ordering parts has never been easier Parts Ordering ProceduresDCA-220SSJ/SSJU Specifications Dimensions DCA-220SSJ/SSJU Dimensions TOP, Side and FrontHazard Symbols DCA-220SSJ/SSJU Safety Message Alert SymbolsThis generator, other property, or DCA-220SSJ/SSJU Safety Message Alert SymbolsDCA-220SSJ/SSJU Rules for Safe Operation General SafetyDrugs or alcohol BurnsDCA-220SSJ/SSJU Rules for Safe Operation Electrical SafetyGenerator Grounding Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyDCA-220SSJ/SSJU Generator Decals Generator Decals Cont inued DCA-220SSJ/SSJU Generator DecalsDCA-220SSJ/SSJU Installation Outdoor Installation DCA-220SSJ/SSJU InstallationIndoor Installation When connecting the generatorDCA-220SSJ/SSJU General Information Major Components DCA-220SSJ/SSJU Major ComponentsDisplay Parameters Menu Button Press this button to enter or exit menu screensFirst Time Start Up DCA-220SSJ/SSJU Diagnostic DisplayNext item down Main Menu NavigationStored Fault Codes Diagnostic CodeEngine Configuration Data To make a selectionDCA-220SSJ/SSJU Diagnostic Display DCA-220SSJ/SSJU Diagnostic Display Display will return to the single or four parameter screen Auxiliary Gage FaultActive Fault Codes Shut Down Codes Backlight AdjustmentCode from an engine control unit the single or four DamageIntensity Contrast AdjustmentIs highlighted Select Units Setup 1- Up DisplaySetup menu Once the Setup 1-up Display menu icon has beenUp display function Automatic Scan on Select the 4-Up Custom Setup from the 4-Up Setup menu Setup 4-Up DisplayHighlighted Engine OIL TemperatureGage Data is selected the PowerView will When the gage data has cleared, the displayVersion currently in the diagnostic display Half duplexMenu Touch the Menu button again to return to the MainTouch the Menu Button Highlight it, then touch Enter Glossary Troubleshooting information DCA-220SSJ/SSJU Diagnostic DisplayECU did not respond to the PowerView request No parameter selected for this 4- UP quadrantDCA-220SSJ/SSJU Generator Control Panel Fuel Gauge Indicates amount of diesel fuel available DCA-220SSJ/SSJU Engine Operating PanelAuto On/Off Engine Controller Mpec DCA-220SSJ/SSJU Engine Operating PanelOutput Terminal Familiarization DCA-220SSJ/SSJU Output Terminal Panel Familiarization100VAC Gfci Receptacles DCA-220SSJ/SSJU Output Terminal Panel FamiliarizationOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadDCA-220SSJ/SSJU Load Application Motors and motor-drivenVoltage Change-Over Board Generator OutputVoltagesGenerator Amperage 100V 200VDCA-220SSJ/SSJU Generator OUTPUTS/ Gauge Reading How to Read the OutputTerminal GaugeMaximum Amps ModelUvwo Terminal Output Voltages DCA-220SSJ/SSJU Output Terminal Panel Connections1Ø-200V UVWOTerminal Output Voltages 3Ø-200V UVWOTerminal Output Voltages3Ø-400V UVWOTerminal Output Voltages DCA-220SSJ/SSJU Output Terminal Panel Connections1Ø-400V UVWOTerminal Output Voltages 1Ø-230V UVWOTerminal Output VoltagesCircuit Breakers DCA-220SSJ/SSJU PRE-SETUPLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorCoolant Antifreeze Operation FreezingWeatherBattery Cable Installation BatteryWiring AlternatorPlace the engine speed switch in the LOW down position DCA-220SSJ/SSJU Generator START-UP Procedure ManualBefore Starting Engines exhaust contains harmful emissionsEngine Speed Switch High When the generator is set Auto mode, the generator will Starting Auto ModeNo Load Tachometer GaugePlace the Mpec Control Switch in the Auto position Place the engine speed switch in the High positionEmergency Shutdown Procedure Normal Shutdown ProcedureDCA-220SSJ/SSJU Maintenance Engine Air Removal Cleaning the Fuel StrainerCheck Oil Level Replacing Oil FilterTo ensure adequate starting DCA-220SSJ/SSJU Maintenance HEATER/CHARGERTrailer Maintenance DCA-220SSJ/SSJU Maintenance TrailerBrakes Brake AdjustmentCheck the wheel and drum for free rotation Hydraulic Surge BrakesTireWear/Inflation Tires/Wheels/Lug NutsSuspension Lug Nut Torque Requirements DCA-220SSJ/SSJU Maintenance TrailerStart all wheel lug nuts by hand DCA-220SSJ/SSJU -TRAILERWIRING Diagram Generator Wiring Diagram DCA-220SSJ/SSJU Generatorwiring DiagramEngine Wiring Diagram DCA-220SSJ/SSJU Enginewiring DiagramGenerator Troubleshooting DCA-220SSJ/SSJU -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-220SSJ/SSJU -TROUBLESHOOTING Engine ControllerDCA-220SSJ/SSJU- Operation and Parts Manual REV. #1 01/06/09 DCA-220SSJ/SSJU Explanation of Code in Remarks Column Sample Parts ListDCA-220SSJ/SSJU Suggested Spare Parts Part number on this Suggested Spare Parts listDCA-220SSJ/SSJU Generator Assy 0601842334 C11100000020601823282 0018205020DCA-220SSJ/SSJU Generator ASSY. 10A 0042610000 001211006510B 0041210000 0017112045DCA-220SSJ/SSJU- Control Panel Assy M4223000404 M42230003030222100100 0222100165DCA-220SSJ/SSJU- Control BOX Assy DCA-220SSJ/SSJU- Control BOX Assy DCA-220SSJ/SSJU- Control BOX ASSY. 0601802218 002710602039A 0601806653 39B 0601802149DCA-220SSJ/SSJU- Engine and Radiator Assy 0602041292 M4923200034RE504836 0602042596DCA-220SSJ/SSJU- Engine and Radiator Assy M4493601204 M4310301203M4310300903 M4310301003DCA-220SSJ/SSJU- Engine and Radiator Assy 0269200660 06020210700802081003 0602010900DCA-220SSJ/SSJU- Outputterminal Assy M9220100304 M42307000030801830804 0039316000DCA-220SSJ/SSJU- Battery Assy C9109100604 01686145510805000904 0805002904DCA-220SSJ/SSJU- Muffler Assy M4333000303 M43301006020602325066 M4333200004DCA-220SSJ/SSJU- Fueltank Assy 0845500104 C13630014030810105400 0605501092Enclosure Assy DCA-220SSJ/SSJU- Enclosure AssyM1413400404 C14130044020019208020 M4423000302Enclosure ASSY. DCA-220SSJ/SSJU- Enclosure ASSY.M4443200403 0207306000M4443600004 28A 0041206000DCA-220SSJ/SSJU- Enclosure ASSY. 51A M4493403804 M4453001203M4453001303 52A M4493403904DCA-220SSJ/SSJU- Rubber Seals Assy 0228900945 02292012400228901200 0228901260DCA-220SSJ/SSJU- Nameplate and Decals Assy B9521100404 M4550000303C9521100003 C1550000102Payment Terms DCA-220SSJ/SSJU- Operation and Parts Manual REV. #1 01/06/09 Lewisville, TX Fax 972
Related manuals
Manual 108 pages 21.73 Kb

DCA-220SSJ specifications

The Multiquip DCA-220SSJ is a high-performance diesel generator renowned for its reliability and efficiency in various applications. Whether in construction, events, or emergency backup, this generator is designed to provide dependable power when you need it most.

One of the main features of the DCA-220SSJ is its powerful 220 kVA output capability. With a robust engine, this generator can support a wide range of equipment, making it suitable for both heavy-duty industrial tasks and lighter applications. It is equipped with a 4-cylinder, liquid-cooled diesel engine, known for its durability and consistent performance. The engine technology used in the DCA-220SSJ ensures low fuel consumption while minimizing emissions, adhering to stringent environmental regulations.

The DCA-220SSJ also features a compact design, making it easy to transport and set up in various locations. Its sturdy skid-mounted frame provides stability and protection to the internal components, while the weather-resistant canopy ensures that it can operate reliably in diverse weather conditions. This design is particularly beneficial for outdoor applications where exposure to the elements is a concern.

An important aspect of the DCA-220SSJ's functionality is its advanced control panel. It includes digital monitoring systems that provide real-time data on performance metrics such as voltage, frequency, and operating hours. This information helps users maintain the generator effectively and plan for servicing to avoid unexpected downtime. The generator also features automatic voltage regulation (AVR), which maintains a stable output voltage, protecting connected equipment from power surges.

Safety is a top priority with the DCA-220SSJ, which includes several built-in safety features. These include low oil pressure shutdown, high-temperature shutdown, and overload protection, ensuring that the generator operates safely under all conditions.

Furthermore, the generator is designed for ease of maintenance, with accessible service points to streamline regular checks and repairs. This helps to extend the lifespan of the unit and ensures reliable operation over time.

In summary, the Multiquip DCA-220SSJ is a versatile and robust diesel generator. With its powerful output, advanced technologies, user-friendly controls, and a strong focus on safety and efficiency, it stands out as an essential tool for various industries needing reliable power solutions.