Break wood in the direction of the grain, never place wood across the log splitter.

Do not hold the log by the ends when you are positioning it onto the log splitter.

Any damaged part of the log splitter should be properly repaired or replaced by an authorized service center, unless otherwise indicated in this instruction manual.

Do not use the log splitter if the switch does not turn it ‘on’ and ‘off’. Have any defective switches replaced by an authorized service center.

Lubricate ram, vertical beam and guides to reduce wear. Use #2 Lithium grease.

NOTE: We recommend that wood be left to air dry, as it will make the splitting process much easier and faster. Wood which is well seasoned also produces up to 44% more heat than green wood.

Several things can limit the splitting capacity of the log splitter: knotty wood, wood with twisted grain, or a stump with roots. The more of these characteristics present in a piece of wood, the more difficult it will be to split.

A knot is that portion of a branch that has become incorporated in the bole of a tree. The influence of a knot on the mechanical properties of a wood member is due to the interruption of continuity and change in the direction of wood fibers associated with the knot.

The diameter of a log does not necessarily indicate the difficulty of the split. A larger log can be split easier than a smaller log, if its fiber is straight.

WARNING

THE PRESSURE RELIEF VALVE PROTECTS THE HYDRAULIC ASSEMBLY WHEN THE LOG IS JAMMED FOR ABOUT 5 SECONDS. THE PRESSURE PLATE SLOWLY TRAVELS DOWN TO THE ORIGINAL POSITION AND CAN BE IMMEDIATELY RE-ACTIVATED.

IF THE LOG DOES NOT SPLIT IMMEDIATELY, DO NOT FORCE THE PRESSURE PLATE

OF THE LOG SPLITTER. STOP THE LOG SPLITTER, REPOSITION THE LOG BY

TURNING IT AND TRY AGAIN. IF THE WOOD STILL CAN NOT BE SPLIT, IT MEANS THAT THE LOG EXCEEDS THE CAPACITY OF THE MACHINE AND IT SHOULD BE REJECTED.

10

Image 11
Contents Log Splitter Manual Table of Contents Unpacking and Assembly Instructions Item no QTY Description Page Safety Decals Service Information Special Safety InformationRead Understand OPERATOR’S Manual Before Using Safety Warnings Important extension cord information Disconnect power cord from power sourceHydraulic safety Before You Start Splitting Page Operation Maximum LOG Size for the Swift Split is 20 Long X 12 DIA Removal of logs jammed on the wedgeHow to change the hydraulic oil Sharpening the wedge Inspect/Sharpen MaintenanceTransport Inspect/LubricateReplace Hydraulic oil Area Maintenance procedure Frequency Inspect /TightenMaintain log splitter with care Visually Inspect All WeldsStorage TroubleshootingProblem Possible cause Remedy Exploded View LOG Splitter Exploded ViewDescription / Remarks QTY Parts ListMantis