CONSOLE DIAGRAM

Temperature

Display

USING THE CONSOLE

Refer to the console diagram above. The function of each console control is explained below:

Temperature Display: During normal use, this dis- play shows the actual water temperature. When the

Set Temp indicator is lit, the display will show the set temperature.

Note: When problems occur, the temperature display may show an error code. The error codes are explained below:

HL High temperature protection mode. If the water temperature rises above 115°F (46°C), the heater will shut off. If the temperature rises

above 122°F (50°C), the high temperature cir- cuit will shut off the entire system. In either

case, once the water has cooled to normal, you can press any button to reset the system.

FrE Freeze protection mode. If the water tempera- ture falls below 40°F (14°C), the pump will begin cycling the water through the heater to raise the temperature. This cycle will run for one minute and may be repeated as needed.

FLC Flow related problems. You will need to call our customer service department.

FLO Flow related problems. You will need to call our customer service department.

PrH High temperature probe problem. You will need to call our customer service department.

Prr Temperature probe problem. You will need to call our customer service department.

Pump Button: This button turns the pump on and off. When the pump is running, the LED indicator above

the button will light. To turn the pump on high, press the button once. The thera-jets will operate at full speed. To turn the pump on low, press the button again. The thera-jets will operate at low speed. After you press the button a third time, the thera-jets will

shut off, unless it is time for the heat or filter cycles. If you turn the pump off and it continues to operate,

check to see if the Heat On or Filter On indicator is lit to see if either cycle is running.

Light Button: This button turns the light on and off. When the light is on, the indicator above the light but- ton will light. Note: The light will automatically turn off after two hours.

Set Temp Indicator: This indicator will light when the temperature is adjusted using the up and down buttons.

The thermostat can be set to heat the water from

70°F to 104°F (21°C to 40°C). While you are setting the temperature, the temperature display will show the temperature setting. The temperature setting will

remain in the display for five seconds after you release the buttons. The Set Temp light will then turn off and the display will show the actual water temper- ature. The water heats at 1.5°F (2°C) per hour with the cover on.

Filter On Indicator: This indicator lights when the spa is running the filter cycle.

Note: To keep the heat and filter cycles from run- ning, shut off the circuit breaker or the GFCI.

Heat On Indicator: This indicator lights when the spa is running the heating cycle.

Air Control: The air control determines the amount of air flowing through the spa jet system during operation. If the control is turned to the left, the amount of air will increase; if the control is turned to the right, the amount of air will decrease.

13

Image 13
Contents QUESTIONS? If you require Service for thisModel No Serial No Limited Five Year Hydrotherapy SPA Warranty Table of ContentsSpa, and it will void the warranty Important Safety InstructionsUse the hydrotherapy spa only as described This manual Never use the hydrotherapy spa alone Minimum No AWG 1.3 mmHigh or low blood pressure, circulatory prob Volt Minimum Breaker/Fuse 15 Amps Before YOU Begin If you set up the hydrotherapy spa outside If you set up the hydrotherapy spa insideChoosing a Location for the Hydrotherapy SPA Hydrotherapy spa should be close to a source of waterOne 1 phillips screwdriver SET-UP and AssemblyDo not use soft water With all local, state, and national electrical codesSpa Make sure that the Spa Cover is centeredPosting the Warning Sign Testing and Treating the Water Testing the Ground Fault Circuit Interrupter GfciStarting the Hydrotherapy SPA Eight fixed thera-jets SPA Shell Diagram SPA OperationSuction vents Suction covers in placeTemperature Display Console DiagramUsing the Console Thermostat can be set to heat the water fromSecuring the SPA Cover Adjusting the Filter CycleLatch Buckle Key Attaching the RED and Blue Light CoversMaintenance Maintaining the Proper PH Balance Water ChemistryDraining the Hydrotherapy SPA Opening and Closing the CUT-OFF Valves Draining the PumpWinter USE and Care Checking and Cleaning the Filter Converting the SPA to a 240 Volt Power SourceAdjusting the Filter Diverter Maintenance Notes Symptom the Pump Hums Symptom the SPA will not OperateTrouble -SHOOTING MustMinimum setting. Note If the water is Symptom the Water Level DropsSome water loss due to evaporation is normal Key No. Qty Description Part LIST-Model NoExploded DRAWING-Model No Is a registered trademark of Icon Health & Fitness, Inc Ordering Replacement PartsPart No R1000A

831.10507 specifications

Inter-Tel 831.10507 is a powerful and versatile telecommunications solution designed to enhance business communication effectiveness. As part of the Inter-Tel product lineup, this device combines cutting-edge technology with user-friendly features, making it a preferred choice for many organizations.

One of the main characteristics of the Inter-Tel 831.10507 is its scalability. It supports growth by accommodating a varying number of users and can be easily expanded to meet the demands of a growing business. This scalability is particularly beneficial for small to mid-sized businesses that anticipate changes in their communication needs over time.

The device is equipped with robust voicemail capabilities. Users have access to a comprehensive voicemail system that offers personalized greetings, message storage, and retrieval options. This feature ensures that important messages are never missed, allowing businesses to maintain a high level of customer service.

In terms of connectivity, the Inter-Tel 831.10507 supports multiple communication protocols, including analog, digital, and Voice over Internet Protocol (VoIP). This extensive compatibility allows businesses to integrate the system into their existing communication infrastructure seamlessly. As a result, organizations can take advantage of both traditional and modern communication methods.

Another noteworthy feature is its call management capabilities. The Inter-Tel 831.10507 includes call forwarding, call waiting, and conference call functionalities. These features empower users to manage their calls efficiently and facilitate smoother collaboration among team members.

The system also boasts a user-friendly interface, making navigation intuitive. Users can easily configure settings, manage contacts, and access features without extensive training or technical knowledge. This ease of use reduces the time and resources spent on training staff, allowing them to focus on their core responsibilities.

Security is a critical concern for any business communication system, and the Inter-Tel 831.10507 addresses this by implementing various security protocols. These measures protect sensitive information and ensure that communications remain confidential.

Moreover, the device is designed for reliability. With a proven track record in various operational environments, it is built to withstand the challenges of day-to-day business activities.

In conclusion, the Inter-Tel 831.10507 is a sophisticated communication tool that combines scalability, advanced features, and user-friendliness. Whether for a startup or a more established company, it provides the flexibility and functionality required to enhance organizational communication, making it a worthwhile investment. By adopting this telecommunications solution, businesses can significantly improve their overall communication efficiency and effectiveness.