Figure D
8.The Spindles are used to assemble and connect the Log Lift (01) to the main unit - See Figure D.
1 3 5
6 2 4 7
9.Connect the hoses as marked (Hose 1 to Connection 1, for example) the hoses will only reach the proper connections if attached in the proper orientation - See Figure E.
Filling the Hydraulic Fluid
Figure F
Hydraulic Oil
Cap (20)
1.Remove the Hydraulic Oil Cap (20) and fill the tank with Hydraulic oil (not included) - See Figure F. Remove and retain the
2.To check the hydraulic oil level, remove the Dipstick connected to the Hydraulic Oil Cap, wipe it clean, then dip it back in. Pull it out once again and check the oil level on the Dipstick.
3.The oil should be at the upper notch of the Dipstick. Be sure that the hydraulic oil level is between 4.5 and 8 gallons. Replace
4.The hydraulic system must be vented during operation or it may become vacuum locked and stop working properly. To vent the system, open the air inlet hole by loosening the Hydraulic Oil Cap. You may have to move the
5.When the Log Splitter is not in operation or being transported, close
SKU 56072 | For technical questions, please call | Page 10 |