QUIETPACT™ 75D Recreational Vehicle Generator

ELECTRICAL HAZARDS

FIRE HAZARDS

The generator covered by this manual produces dangerous electrical voltages that can cause fatal electrical shock. Avoid contact with bare wires, ter- minals, connections, etc., while the unit is running. Ensure all appropriate covers, guards, and barri- ers are in place before operating the generator. If work must be done around an operating unit, stand on an insulated, dry surface to reduce shock hazard.

Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT.

During installation onto the vehicle, properly ground (bond) the generator either by solid mount- ing to the vehicle frame or chassis, or by means of an approved bonding conductor. DO NOT connect the bonding conductor to any generator part that might be removed or disassembled during routine maintenance. If the grounding conductor must be replaced, use only a flexible conductor that is of No. 8 American Wire Gauge (AWG) copper wire minimum.

If the vehicle electrical circuits can be powered by any other source of electricity (such as, a “dockside” power receptacle), there must be no possibility of connecting the different power sources to the vehi- cle’s circuits at the same time. The dockside (utility) power source must be positively isolated from the vehicle’s circuits whenever the generator is operat- ing. Failure to isolate the vehicle’s circuits from the dockside power supply when the generator is run- ning may result in damage to the generator or in serious injury or death to dockside (utility) power workers due to backfeed of electrical energy.

In case of an accident caused by electric shock, immediately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a noncon- ducting implement, such as, a rope or board, to free the victim from the live conductor. If the vic- tim is unconscious, apply first aid, and get immediate medical help.

Never wear jewelry when working on this equip- ment. Jewelry can conduct electricity, resulting in electric shock, or may get caught in moving com- ponents, causing injury.

For fire safety, the generator must be installed and maintained properly. Installation always must comply with applicable codes, standards, laws, and regulations. Adhere strictly to local, state and national electrical and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has estab- lished. Also, ensure that the generator is installed in accordance with the manufacturer’s instructions and recommendations. Following proper installation, do nothing that might alter a safe installation and render the unit in noncom- pliance with the aforementioned codes, stan- dards, laws, and regulations.

Keep a fire extinguisher in the vehicle at all times. Extinguishers rated “ABC” by the National Fire Protection Association are appropriate for use on the recreational vehicle generator electrical system. Keep the extinguisher properly charged, and be familiar with its use. If there are any questions per- taining to fire extinguishers, consult the local fire department.

EXPLOSION HAZARDS

Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no com- bustible materials are left in the generator com- partment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surround- ing the generator clean and free from debris.

All fuel types are potentially FLAMMABLE and/or EXPLOSIVE and should be handled with care. Comply with all laws regulating the storage and han- dling of fuels.

Fuel supply lines must be properly installed, purged and leak-tested according to applicable fuel-gas codes, before placing this equipment into service. There must be no possibility of fuel vapors enter- ing the vehicle interior.

It is required that an approved, flexible, noncon- ductive fuel line between the generator fuel con- nection point and the rigid fuel lines be installed.

Generac® Power Systems, Inc. 19

Image 21
Contents Liquid-cooled Recreational Vehicle Generator Introduction Authorized Service Dealer LocationTable of Contents Part II Installation InstructionsGeneral Hazards Electrical Hazards Generator Identification ModelQuietpact 75D Specifications SafetyGenerator Applicability Generator AC Connection SystemEngine OIL Requirements Fuel Consumption GAL/HRCoolant EngineGenerator Control Panel Optional Remote START/STOPBefore Starting the Engine Starting the Generator Protection Systems Stopping the GeneratorOverspeed Shutdown Additional InformationOvervoltage Protection 1 25-HOUR BREAK-IN PeriodChanging the Engine OIL AND/OR OIL Filter Checking the Engine OIL LevelOperation in High Grass or Brush Effects of Moisture and DirtSpark Arrestor Muffler Servicing the Engine AIR FilterBattery Maintenance Cleaning the GeneratorEngine Coolant Cooling SystemDrive Belt Exercising the GeneratorOUT-OF-SERVICE Procedure Removal from ServiceReturn to Service Service Schedule Part General Hazards Fire Hazards Standards Booklets Purpose and Scope ManualEquipment Description Generator Engine Operating SpeedMajor Features and Dimensions Generator Location Location and SupportGenerator Support Suspended MountingGenerator Compartments Generator RestraintCompartment Construction Acoustics Sound Insulating MaterialsTypical Noise Abatement 2.2.4 Compartment Floor Cutouts Cooling and Ventilating AIR Cooling AIR Inlet OpeningsGenerator Airflow Testing the Installation Diesel Fuel SystemCompensating for Restrictions Fuel Tank Generator Fuel Supply LinesGenerator Fuel Return Lines Exhaust System Safety Exhaust SystemMuffler and Spark Arrestor Electrical Connections WiringElectrical Junction BOX Generator AC ConnectionsVolts Only Dual Circuits Generator Coversion toPower Supply Cord Isolating Different Power SourcesConduit Recommended Battery Battery InstallationBattery Cables Battery Cable ConnectionsOptional Accessories Battery CompartmentRemote START/STOP Connections Testing Under Load Post Installation TestsBefore Initial Startup Initial StartInstallation Checklist Problem Cause Correction Troubleshooting GuideAppendix 2 Notes Appendix 2 Notes Appendix 3 Electrical Data Appendix 3 Electrical Data Appendix 3 Electrical Data Wiring Diagram 120 VAC- Drawing No. 0D2793-B Part Part NO. QTY Description 677mm Item Part NO. QTY. Description 0C4554 Shaft, Fan 0C4845 Gasket, Electrical Enclosure Divider Exhaust Gasket 0C6946A Fuel Pump Assembly 023484F Snap Bushing 052219 2118 11 29 32 33 Camshaft Assembly Complete Cylinder Block Cylinder Head Assembly Crankshaft Assembly Idler Gear Assembly Rocker ARM Assemblyincludes ALL Components Shown below Injector Pump Assembly Fuel Filter Support HOUSING, Timing Gear OIL PAN Water Pump Assembly Appendix 5 Notes Your Warranty Rights and Obligations Federal and California Emissions Control Warranty StatementManufacturers Warranty Coverage Parts CoveredObtaining Warranty Service Obligations and Rights of the Manufacturer and OwnerLimitations Warranty Schedule CONSUMER/PERSONAL Applications

004270-2 specifications

Guardian Technologies has made significant strides in air purification technology with its model 004270-2, which stands out for its advanced features and impressive performance. Designed to enhance indoor air quality, this air purifier combines efficiency and innovation to create a healthier living environment.

One of the most notable features of the Guardian Technologies 004270-2 is its multi-layer filtration system. This system includes a true HEPA filter that captures 99.97% of airborne particles as small as 0.3 microns. This means that allergens such as dust mites, pet dander, and pollen are effectively removed from the air. In addition to the HEPA filter, the unit also incorporates a charcoal filter that eliminates unpleasant odors, making it perfect for homes with pets or cooking frequently.

The Guardian Technologies 004270-2 employs UV-C light technology to further enhance its air purification capabilities. This innovative feature works by using ultraviolet light to kill bacteria and viruses, promoting a healthier atmosphere. The combination of HEPA filtration and UV-C technology sets this model apart from standard air purifiers, providing an extra layer of protection against harmful microorganisms.

Another characteristic that contributes to the efficiency of the Guardian Technologies 004270-2 is its quiet operation. This model is engineered to minimize noise levels, making it suitable for use in bedrooms, living spaces, or offices without disrupting daily activities. Users can enjoy clean air without the annoyance of constant fan noise.

The design of the 004270-2 is also worth mentioning. Its sleek, modern appearance allows it to fit seamlessly into any room decor while being compact enough for easy placement. Additionally, the unit features a filter change indicator, ensuring that users are aware when it’s time to replace the filters for optimal performance.

Energy efficiency is another advantage of this air purifier, as it is designed to consume less power while providing powerful air purification. This not only helps in reducing electricity bills but also promotes eco-friendly practices.

In summary, the Guardian Technologies 004270-2 is an exemplary air purifier that boasts a robust filtration system, innovative UV-C technology, quiet operation, and energy efficiency. It effectively addresses common indoor air quality concerns, making it an ideal choice for households seeking a healthier atmosphere.