Guardian Technologies 004270-2 owner manual Part II Installation Instructions, Table of Contents

Page 3

Table of Contents

QUIETPACT™ 75D Recreational Vehicle Generator

Part I – Owner’s Manual

Introduction

Inside Front Cover

Read This Manual Thoroughly

IFC

Contents

IFC

Operation and Maintenance

IFC

How to Obtain Service

IFC

Authorized Service Dealer Locator Number

....................IFC

Safety Rules

......................................................................

2

Section 1 – General Information

4

1.1

Generator Identification

4

1.2

Generator Applicability

5

1.3

Safety

5

1.4

Generator AC Connection System

5

1.5

Specifications

5

 

1.5.1

Fuel Requirements

5

 

1.5.2

Fuel Consumption

6

 

1.5.3

Engine Oil Requirements

6

 

1.5.4

Coolant

6

 

1.5.5

Engine

6

 

1.5.6

Generator

6

Section 2 – Operation

7

2.1

Generator Control Panel

7

 

2.1.1

Hourmeter

7

 

2.1.2

Start/Stop Switch

7

 

2.1.3

Fuse

7

 

2.1.4

Line Breaker

7

 

2.1.5

Preheat Switch

7

2.2

Optional Remote Start/Stop

7

2.3

Before Starting the Engine

7

 

2.3.1

Installation

7

 

2.3.2

Engine Lubrication

8

 

2.3.3

Fuel Supply

8

 

2.3.4

Coolant Level

8

 

2.3.5

Cooling and Ventilating Air

8

 

2.3.6

Engine Exhaust Gas

8

2.4

Starting the Generator

8

2.5

Stopping the Generator

9

2.6

Applying Loads to Generator

9

 

2.6.1 Letting the Engine Stabilize

9

 

2.6.2 Do Not Overload the Generator

9

2.7

Protection Systems

9

 

2.7.1 Low Oil Pressure Switch

9

 

2.7.2 High Coolant Temperature Switch

9

 

2.7.3

Overspeed Shutdown

10

 

2.7.4

Overvoltage Protection

10

2.8

Additional Information

10

 

2.8.1

25-Hour Break-in Period

10

 

2.8.2

25-Hour Check-up

10

 

2.8.3 Attention Required After Submersion

10

 

2.8.4 Operation in High Grass or Brush

11

 

2.8.5 Effects of Moisture and Dirt

11

Section 3 – Maintenance

11

3.1

Checking the Engine Oil Level

11

3.2

Changing the Engine Oil and/or Oil Filter

11

3.3

Servicing the Engine Air Filter

12

3.4

Spark Arrestor Muffler

12

3.5

Cleaning the Generator

13

3.6

Battery Maintenance

13

3.7

Cooling System

14

3.8

Engine Coolant

14

3.9

Major Service Manual

14

3.10

Drive Belt

14

3.11

Exercising the Generator

14

3.12

Out-of-Service Procedure

15

 

3.12.1

Removal From Service

15

 

3.12.2

Return to Service

15

3.13

Service Schedule

16

Part II – Installation Instructions

Safety Rules

18

Section 1 – General Information

20

1.1

Purpose and Scope of the Manual

20

1.2

Safety

......................................................................

20

1.3

Standards Booklets

20

1.4

Equipment Description

20

1.5

Generator Engine Operating Speed

20

1.6

Generator AC Connection System

20

Section 2 – Installation

22

2.1

Location and Support

22

 

2.1.1

Generator Location

22

 

2.1.2

Generator Support

22

 

2.1.3

Suspended Mounting

22

 

2.1.4

Generator Restraint

23

2.2

Generator Compartments

23

 

2.2.1

Compartment Construction

23

 

2.2.2

Sound Insulating Materials

24

 

2.2.3

Acoustics

24

 

2.2.4

Compartment Floor Cutouts

25

2.3

Cooling and Ventilating Air

26

 

2.3.1

Generator Airflow

26

 

2.3.2 Cooling Air Inlet Openings

26

 

2.3.3

Compensating for Restrictions

27

 

2.3.4

Testing the Installation

27

2.4

Diesel Fuel System

27

 

2.4.1

Fuel Tank

28

 

2.4.2 Generator Fuel Supply Lines

28

 

2.4.3 Generator Fuel Return Lines

28

2.5

Exhaust System

29

 

2.5.1 Muffler and Spark Arrestor

29

 

2.5.2

Exhaust System Safety

29

2.6

Electrical Connections

30

 

2.6.1

Electrical Junction Box

30

 

2.6.2

Wiring

30

 

2.6.3

Generator AC Connections

30

 

2.6.4

Conduit

32

 

2.6.5

Power Supply Cord

32

 

2.6.6 Ground Fault Circuit Interrupters

32

 

2.6.7 Isolating Different Power Sources

32

2.7

Battery Installation

33

 

2.7.1

Recommended Battery

33

 

2.7.2

Battery Cables

33

 

2.7.3

Battery Cable Connections

33

 

2.7.4

Battery Compartment

34

2.8

Optional Accessories

34

 

2.8.1

Remote Start/Stop Connections

34

Section 3 – Post-installation Startup

35

 

 

Checks

3.1

Post Installation Tests

35

3.2

Before Initial Startup

35

3.3

Initial Start

35

3.4

Testing Under Load

35

3.5

Installation Checklist

36

Appendix 1 – Troubleshooting

37

Appendix 2 - Notes

38

Appendix 3 – Electrical Data

40

Appendix 4 – Exploded Views and Parts Lists

44

Appendix 5 – Notes

63

Appendix 6 – Warranty

64

Generac® Power Systems, Inc. 1

Image 3
Contents Liquid-cooled Recreational Vehicle Generator Introduction Authorized Service Dealer LocationTable of Contents Part II Installation InstructionsGeneral Hazards Electrical Hazards Generator Identification ModelQuietpact 75D Generator AC Connection System SafetySpecifications Generator ApplicabilityEngine Fuel Consumption GAL/HREngine OIL Requirements CoolantGenerator Control Panel Optional Remote START/STOPBefore Starting the Engine Starting the Generator Protection Systems Stopping the Generator1 25-HOUR BREAK-IN Period Additional InformationOverspeed Shutdown Overvoltage ProtectionEffects of Moisture and Dirt Checking the Engine OIL LevelChanging the Engine OIL AND/OR OIL Filter Operation in High Grass or BrushSpark Arrestor Muffler Servicing the Engine AIR FilterBattery Maintenance Cleaning the GeneratorExercising the Generator Cooling SystemEngine Coolant Drive BeltOUT-OF-SERVICE Procedure Removal from ServiceReturn to Service Service Schedule Part General Hazards Fire Hazards Generator Engine Operating Speed Purpose and Scope ManualStandards Booklets Equipment DescriptionMajor Features and Dimensions Suspended Mounting Location and SupportGenerator Location Generator SupportGenerator Compartments Generator RestraintCompartment Construction Acoustics Sound Insulating MaterialsTypical Noise Abatement 2.2.4 Compartment Floor Cutouts Cooling and Ventilating AIR Cooling AIR Inlet OpeningsGenerator Airflow Testing the Installation Diesel Fuel SystemCompensating for Restrictions Fuel Tank Generator Fuel Supply LinesGenerator Fuel Return Lines Exhaust System Safety Exhaust SystemMuffler and Spark Arrestor Generator AC Connections WiringElectrical Connections Electrical Junction BOXVolts Only Dual Circuits Generator Coversion toPower Supply Cord Isolating Different Power SourcesConduit Battery Cable Connections Battery InstallationRecommended Battery Battery CablesOptional Accessories Battery CompartmentRemote START/STOP Connections Initial Start Post Installation TestsTesting Under Load Before Initial StartupInstallation Checklist Problem Cause Correction Troubleshooting GuideAppendix 2 Notes Appendix 2 Notes Appendix 3 Electrical Data Appendix 3 Electrical Data Appendix 3 Electrical Data Wiring Diagram 120 VAC- Drawing No. 0D2793-B Part Part NO. QTY Description 677mm Item Part NO. QTY. Description 0C4554 Shaft, Fan 0C4845 Gasket, Electrical Enclosure Divider Exhaust Gasket 0C6946A Fuel Pump Assembly 023484F Snap Bushing 052219 2118 11 29 32 33 Camshaft Assembly Complete Cylinder Block Cylinder Head Assembly Crankshaft Assembly Idler Gear Assembly Rocker ARM Assemblyincludes ALL Components Shown below Injector Pump Assembly Fuel Filter Support HOUSING, Timing Gear OIL PAN Water Pump Assembly Appendix 5 Notes Parts Covered Federal and California Emissions Control Warranty StatementYour Warranty Rights and Obligations Manufacturers Warranty CoverageObtaining Warranty Service Obligations and Rights of the Manufacturer and OwnerLimitations Warranty Schedule CONSUMER/PERSONAL Applications

004270-2 specifications

Guardian Technologies has made significant strides in air purification technology with its model 004270-2, which stands out for its advanced features and impressive performance. Designed to enhance indoor air quality, this air purifier combines efficiency and innovation to create a healthier living environment.

One of the most notable features of the Guardian Technologies 004270-2 is its multi-layer filtration system. This system includes a true HEPA filter that captures 99.97% of airborne particles as small as 0.3 microns. This means that allergens such as dust mites, pet dander, and pollen are effectively removed from the air. In addition to the HEPA filter, the unit also incorporates a charcoal filter that eliminates unpleasant odors, making it perfect for homes with pets or cooking frequently.

The Guardian Technologies 004270-2 employs UV-C light technology to further enhance its air purification capabilities. This innovative feature works by using ultraviolet light to kill bacteria and viruses, promoting a healthier atmosphere. The combination of HEPA filtration and UV-C technology sets this model apart from standard air purifiers, providing an extra layer of protection against harmful microorganisms.

Another characteristic that contributes to the efficiency of the Guardian Technologies 004270-2 is its quiet operation. This model is engineered to minimize noise levels, making it suitable for use in bedrooms, living spaces, or offices without disrupting daily activities. Users can enjoy clean air without the annoyance of constant fan noise.

The design of the 004270-2 is also worth mentioning. Its sleek, modern appearance allows it to fit seamlessly into any room decor while being compact enough for easy placement. Additionally, the unit features a filter change indicator, ensuring that users are aware when it’s time to replace the filters for optimal performance.

Energy efficiency is another advantage of this air purifier, as it is designed to consume less power while providing powerful air purification. This not only helps in reducing electricity bills but also promotes eco-friendly practices.

In summary, the Guardian Technologies 004270-2 is an exemplary air purifier that boasts a robust filtration system, innovative UV-C technology, quiet operation, and energy efficiency. It effectively addresses common indoor air quality concerns, making it an ideal choice for households seeking a healthier atmosphere.