Section 9 - Exploded Views and Parts

 

 

 

 

 

 

 

 

 

 

 

 

Guardian Liquid-cooled 25 kW Generators

 

 

 

 

Acoustic Compartment — Drawing No. 0E0772-H

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

1

0D8666

1

ROOF ACSTC & STND CMPRTMNT 1.5L

 

2

0D8664C

1

DUCT CENTER 1.5L

 

3

0D8657

1

SUPPORT RADIATOR 1.5L MITSU

 

4

0D8660

2

BRACE SIDE 1.5L MITSU

 

5

0A7568

2

DOOR WELDMENT 1.5 EPS

 

6

0D8659

1

CORNER POST REAR RH SIDE 1.5L

 

7

0D8662

1

DOOR REAR COMPARTMENT 1.5L

 

8

0D8661

1

BRACE REAR 1.5L MITSU

 

9

0D8658

1

CORNER POST REAR LH SIDE 1.5L

 

10

067042

2

LATCH & CAM

 

11

0C2454

40

SCREW TH-FRM M6-1 X 16 N WA Z/JS

 

12

033530

3

SCREW PHM #10-32 X 5/8 ZINC

 

13

051716

3

NUT HEX M5-0.8 G8 YEL CHR

 

14

022152

3

WASHER LOCK #10

 

15

0912970064

3

ASSEMBLY BASE-DOOR GROUND WIRE

 

16

023762

3

WASHER SHAKEPROOF EXT #10 STL

 

17

0912970063

3

GRD WIRE ASS'Y 99HSB

 

18

022264

6

WASHER LOCK #8-M4

 

19

067035

6

SCREW PPHM #8-32 X 5/16

 

20

078115

13

WASHER SELF LOCKING DOME

 

21

0C2634A

1

ASSEMBLY COVER ACCESS

 

22

022473

9

WASHER FLAT 1/4 ZINC

 

23

022097

9

WASHER LOCK M6-1/4

 

24

022127

9

NUT HEX 1/4-20 STEEL

 

25

0D8663

2

BAFFLE CNTRL PNL 1.5L ACOUSTIC

 

26

0D8665

2

BAFFLE DOOR 1.5L ACOUSTIC UNIT

 

27

0E0072D

1

ACSTC INSLTN 1.5L DUCT RH PNL

 

28

0E0072B

1

ACSTC INSLTN 1.5L DUCT LH PNL

 

29

0E0072Q

2

ACSTC INSLTN 1.5L RAD SUPPORT

 

30

0E0072C

1

ACSTC INSLTN 1.5L DUCT FNT PNL

 

31

0E0072A

1

ACSTC INSLTN 1.5L ROOF PANEL

 

32

0E0072M

2

ACSTC INSLTN 1.5L SIDE DR PNL

 

33

0E0072P

2

ACSTC INSLTN 1.5L SIDE DR PNL

 

34

0E0072L

2

ACSTC INSLTN 1.5L SIDE BRC PNL

 

35

0E0072N

2

ACSTC INSLTN 1.5L DR BAFFLE PL

 

36

0E0072G

2

ACSTC INSLTN 1.5L RR CRNR TOP

 

37

0E0072J

2

ACSTC INSLTN 1.5L RR CRNR BOTT

 

38

0E0072F

1

ACSTC INSLTN 1.5L REAR DR PNL

 

39

0E0072E

1

ACSTC INSLTN 1.5L REAR BRC PNL

 

40

0E0072K

2

ACSTC INSLTN 1.5L BAFFLE PANEL

 

41

0E0072H

2

ACSTC INSLTN 1.5L CNTRL SUPPT

 

42

0D2023

3

GASKET CLIP-ON SELF GRIPPING

 

43

0F3390

1

LATCH AND CAM

 

45

037337

6

NUT HEX JAM 3/8-24 SS

 

46

0D8664A

1

DUCT LH SIDE 1.5L

 

47

0D8664B

1

DUCT RH SIDE 1.5L

 

48

0E0072R

2

INSUL ACO 1.5L DUCT FRNT PNL

 

49 *

0F1563

1

O-RING 5.737 X 5.943

 

50 *

0C2634

1

COVER ACCESS GEN 2000

* I/N'S 49 & 50 PART OF I/N 21.

Generac® Power Systems, Inc. 35

Image 37
Contents Liquid-cooled, Prepackaged Standby Generators ‹ Operation and Maintenance Authorized Service Dealer Location‹ HOW to Obtain Service IntroductionIntroduction IFC Safety Rules General Hazards Electrical Hazards Generator Transfer SwitchAutomatic System Operation Generator AC Connection Systems‹ 1.7.2 High Coolant Temperature Switch ‹ 1.7.1 LOW OIL Pressure Switch‹ 1.7.3 LOW Coolant Level Switch Engine Protective DevicesLifting the Generator UnpackingReconfiguring the Fuel System Specifications‹ 1.10.1 Generator Specifications ‹ 1.10.2 Engine SpecificationsEngine OIL Recommendations Torque SpecificationsCoolant Recommendations Generator Mounting Support Generator LocationBasic Standby Electric System ‹ 2.1.1 Nfpa StandardsEmergency Circuit Isolation Method Transfer Switch Start Signal ConnectionsTotal Circuit Isolation Method Grounding the GeneratorPreparation Before START-UP Battery Installation‹ 2.10.1 Vented Batteries ‹ 2.11.1 Prior to Initial START-UPUsing a Standard GTS Transfer Switch Manual Transfer START-UP Automatic Operation Control Console ComponentsWeekly Exercise Cycle Every Three Months Engine HeaterOnce Every SIX Months Once AnnuallyChecking Fluid Levels Cooling SystemOverload Protection for Engine DC Electrical System ‹ 4.5.1 Check Engine OIL Level ‹ 4.5.2 Check Battery‹ 4.5.3 Exercise System ‹ 4.5.4 Inspect Cooling System‹ 4.5.11 Changing the Engine AIR Cleaner Miscellaneous Maintenance‹ 4.6.1 Cleaning the Generator ‹ 4.5.13 Coolant Change‹ 4.6.4 Battery Replacement ‹ 4.6.3 Battery MaintenanceService Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsGuardian Liquid-cooled 15 kW, 20 kW and 25 kW Generators Guardian Liquid-cooled 15 kW, 20 kW and 25 kW Generators Installation Diagram Section Electrical Data Customer Connection 120/240V 1-PHASE Electrical Data Connector Interface Assembly Housing Governor ConnectorCover Connector Housing ASM Motor StepperWasher Shakeproof EXT 5/16 STL Base Mounting 1.5L Stnrd & AcstcDampener Vibration Washer Flat 5/16 ZincWeld Stud Under Roof Panel for Access Cover Cable GRD Wire Assy 99HSB Assembly BASE-DOOR Ground WireAssembly Cover Access Cover Access GENWeld Stud Under Roof For Access Cover Cable Door Weldment 1.5 EPS Roof Acstc & Stnd Cmprtmnt 1.5LWasher Self Locking Dome Baffle Cntrl PNL 1.5L AcousticTo a Silksc Wire AssemblyHourmeter Holder FuseWaterpump Hardware ARM Adjust Alternator Switch OIL PressureGround Wire Starter Clamp for Wiring Harness not Shown16 7 Radiator 1.5L Tank Coolant RecoveryVenturi 1.5L Modine Guard FAN 1.5L ModineVapor Gasket AIR Cleaner Adapter Cover AIR CleanerWeldment Mounting Base Flange Fuel Inlet16 30 21 Assy Rotor 10KW Housing BlowerAssy Rotor 15KW Assy Rotor 20KWBOOT, Battery Cable ASSY,WIRE#16 REDBRACKET, Battery Hold Down Battery Post Cover RED+Nipple TOE 1.5NPTX5.5 BLK Iron Manifold Exhaust 1.5LSaddle 2 Inch PIPE,EXHAUST 1.5L STNDRD&ACSTCMANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule

004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, 004726-0 specifications

Generac Power Systems is a leader in energy solutions, committed to providing reliable power products for homes, businesses, and industrial applications. Among their extensive range of products, the Generac Power Systems models 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, and 004726-0 stand out due to their advanced features and innovative technologies.

One of the key features of these models is the robust engine performance. They are designed with Generac's signature engines, which ensure optimal power output and durability. This leads to better energy efficiency while maintaining a low operating cost. The models are engineered for seamless operation under various load conditions, ensuring that you stay powered in any situation.

These Generac models also incorporate state-of-the-art transfer switch technology, which enhances their reliability. The transfer switches ensure that power is instantly transferred from the grid to the generator during an outage, allowing for uninterrupted service. This is especially critical for homes and businesses where power reliability is essential.

Combining convenience with efficiency, the models feature user-friendly interfaces that simplify operation. With available mobile monitoring options, users can keep track of their power status and diagnostics remotely. This is a game changer for individuals who want to maintain oversight of their energy solutions without being physically present.

Safety is another critical aspect integrated into the Generac Power Systems. The models are equipped with advanced safety features such as overload protection, low oil shutdown, and high-temperature shutdown, ensuring an added layer of security for users.

Moreover, these models are built with rugged construction materials making them suitable for all environmental conditions. Whether it’s extreme cold or heat, they are crafted to withstand the elements while performing at peak efficiency.

Generac Power Systems emphasizes sustainability as well, with models designed for lower emissions and quieter operation. This is ideal for homeowners and businesses conscious of their environmental impact and seeking to reduce noise pollution.

Overall, the Generac Power Systems models 004721-0, 004722-0, 004723-0, 004724-0, 004725-0, 004725-1, 004725-2, 004725-3, and 004726-0 represent the evolution of power generation technology. With their robust features, efficient operation, and commitment to safety, these generators are an excellent investment for anyone seeking reliable power solutions.