Generac Power Systems 0046263, 0043733, 0046264, 0046262, 0043734 Fuel Requirements Recommendations

Page 8

Section 1 — General Information

Guardian Liquid-cooled 40 kW Generator

‹1.8.2 GENERATOR AND LOAD COMPATIBILITY

The generator must be fully compatible with the rated voltage, number of phases and frequency of the con- nected electrical loads. The generator, connected elec- trical devices, or both, can be damaged if voltage, num- ber of phases and frequency are not compatible.

NOTE:

This manual assumes that the standby generator has been properly selected, installed and interconnected by a competent, qualified electrician or installation contractor. Once the installation is complete, do nothing that may result in noncompatibility between the generator and connected electrical loads.

1.9FUEL REQUIREMENTS

AND RECOMMENDATIONS

With LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed above the liquid fuel in the storage tank.

Recommended fuels should have a Btu content of at least 1,000 Btus per cubic foot for natural gas; or at least 2,520 Btus per cubic foot for LP gas. Ask your fuel supplier for the Btu content of your fuel.

Fuel pressure for both natural gas and liquid propane setups should be 11 inches to 14 inches of water column (0.6 psi) at all load ranges.

‹ 1.8.3 ENGINE

Make

General Motors

Displacement

4.3 liters (262 cu. in.)

Cylinder Arrangement

V-6

Valve Arrangement

Overhead Valves

Firing Order

1-6-5-4-3-2

Number of Main Bearings

4

Compression Ratio

9.4-to-1

No. of Teeth on Flywheel

168

Ignition System

Electronic

Ignition Timing at 1,800 rpm

40 degrees BTDC

Rated Horsepower at 1,800 rpm

......................................67

Spark Plug Gap

0.045 inch (1.1 mm)

Recommended Spark Plugs

AC 41-932 or equivalent

Oil Pressure

30-50 psi

Crankcase Oil Capacity

4.5 U.S. quarts (4.25 L)

Recommended Engine Oil

SAE 15W-40

Type of Cooling System

Pressurized, closed recovery

Cooling Fan

Pusher Type

Cooling System Capacity

4.5 U.S. gallons (17 L)

Recommended Coolant

Use a 50-50 mixture of

ethylene glycol and soft water.

Fuel Consumption

Gaseous fuels such as natural gas and liquid propane (LP) gas are highly explosive. Even the slightest spark can ignite such fuels and cause an explosion. No leakage of fuel is permitted. Natural gas, which is lighter than air, tends to collect in high areas; LP gas is heavier than air and tends to settle in low areas – install leak detectors accord- ingly.

‹1.9.1 CONVERSION TO LP GAS VAPOR

The generator is shipped from the factory configured for using natural gas as fuel. To convert the fuel system to LP gas, proceed as follows (Figure 1.3).

1.Remove end cap from the pressure reducer valve.

2.Turn the tension screw counterclockwise until all ten- sion is removed from the inner spring.

3.Install and tighten the end cap.

4.Invert the pressure reducer valve. In other words, turn it upside down (end cap facing downward).

5.Purge and leak test the entire fuel system according to gaseous fuel codes. NO LEAKS can appear at any point in the system.

Figure 1.3 – Conversion to LP Gas Vapor

Natural Gas

..............................................................720 cfh

LP Gas

288 cfh/7.9gph

6 Generac® Power Systems, Inc.

Image 8
Contents 0046262, 0046263 Introduction Authorized Dealer LocationIntroduction Inside Front Cover General Hazards Electrical Hazards Prepackaged Transfer Switch UNPACKING/INSPECTIONGenerator Generator AC Connection SystemsEngine Protective Devices SpecificationsMain Circuit Breaker ‹ 1.9.1 Conversion to LP GAS Vapor Fuel Requirements Recommendations‹ 1.8.2 Generator and Load Compatibility ‹ 1.12.1 AIR Fuel Ratio Controller Emissions Control SystemCoolant Standby Generator Installation Basic Standby Electric SystemNfpa Standards Other Published StandardsTransfer Switch Start Signal Connections ‹ 2.6.1 PRE-PACKAGED Type SwitchMethod Grounding the Generator‹ 2.7.1 Vented Batteries Battery InstallationPreparation Before START-UP ‹ 2.8.2 Transfer Switch ‹ 2.8.1 Prior to Initial START-UP‹ 2.8.3 Fuel System ‹ 2.8.4 Generator SET LubricationUsing the AUTO/OFF/MANUAL Switch ‹ 3.2.3 Manual Position Sequence of Automatic OperationEngine Heater Weekly Exercise Cycle Checking the Engine OIL LevelChanging the Engine AIR Cleaner ‹ 4.2.2 OIL and Filter Change ProcedureChanging the Engine OIL and Filter ‹ 4.2.1 Engine OIL RecommendationsSpark Plugs Battery Maintenance‹ 4.5.1 Battery Replacement Miscellaneous Maintenance Cooling SystemOverload Protection for DC Fuse‹ 4.11.2 Return to Service OUT of Service Procedure‹ 4.11.1 Removal from Service Service Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionElectrical Data TS1 Generator D4992-A Guardian Liquid- Panel 4.3L Drawing No Section Wiring Diagram Control Panel Model No KW Generators No D6975 EC1 ACT Drain Pan Oil QTY Description Base Frame Assembly M6 Hinge Panel Face Panel BTM & Back Control Exploded Views and Parts Lists Cover Plate AVR ALT Leads Sensing Wire QTY To Engine Flywheel Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists MOUNT, Engine R & L KIT Radiator Copper Brass DIA. Clamp Assembly 2 Compartment To Engine Front NUT Wing 1/4-20 Nylk To Stepper Motor Support Solenoid NAT GAS Attach to REGULATOR, N/G R600S Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper To Thermostat Housing Guardian Liquid-cooled 40 kW Generators Guardian Liquid-cooled 40 kW Generators PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule This Warranty Shall not Apply to the Following

0043735, 0043734, 0046262, 0046263, 0046264 specifications

Generac Power Systems has established itself as a leader in the power generation industry, best known for its wide range of products designed for various power needs. Among its offerings are model numbers 0043733, 0046264, 0046263, 0046262, and 0043734. Each unit reflects Generac's commitment to innovation, reliability, and efficiency in providing backup power solutions.

The Generac model 0043733 is a powerful portable generator known for its robust performance and user-friendly design. It typically features a high starting wattage, capable of powering essential appliances during outages. With a compact design and ergonomic handle, it ensures easy transportability, making it an excellent choice for outdoor activities or emergency backup. This model often incorporates advanced technology such as digital watt meters for real-time monitoring and fuel level indicators to enhance user convenience.

Moving on to model 0046264, this unit is engineered for reliability in home standby applications. Its automatic transfer switch allows for seamless switching from grid power to generator power in the event of an outage. This ensures a continuous power supply without any manual intervention. Generac's Quiet-Test technology makes this model exceptionally quiet, operating at a lower decibel level compared to traditional generators, enhancing its suitability for residential areas.

The 0046263 model is similar to the 0046264 but is designed for slightly different power requirements and configurations. It offers a range of customizable options, allowing users to tailor the system to their specific needs. Advanced monitoring capabilities often come standard, enabling users to track performance and receive alerts via smartphone or other devices.

Model 0046262 is also tailored for homeowners, focusing on versatility and efficiency. It usually features a highly efficient engine, capable of providing substantial power while optimizing fuel consumption. Its sturdy build ensures durability, making it suitable for various weather conditions.

Lastly, the 0043734 model is designed for commercial use, capable of handling larger power needs. It typically comes equipped with technologies such as remote monitoring and diagnostics, making it easier to maintain and service. With a heavy-duty construction, this model is built to withstand demanding environments while providing reliable, uninterrupted power.

In summary, Generac Power Systems offers a diverse range of backup power solutions through models such as 0043733, 0046264, 0046263, 0046262, and 0043734. With features focusing on portability, reliability, efficiency, and advanced technology, these models cater to various power requirements, ensuring customers can find the ideal generator for their needs.