Generac Power Systems 0043734, 0043733, 0046264, 0046263, 0046262, 0043735 To Stepper Motor

Page 52

Section 7 — Exploded Views and Parts Lists

(Model No. 0043733, 0043734 & 0043735) Guardian Liquid-cooled 40 kW Generators 4.3L Nat. Gas Fuel System – Drawing No. 0E0714

13

12

13

11

12

11

18

17

19 6

7

18

25

TO STEPPER MOTOR

 

17

 

40

24 2

39

28

29

30

3

3 3 1

34

 

 

13

 

 

12

 

 

11

2

 

 

24

9

 

 

8

10

6

5

 

 

24

 

 

 

 

 

1

4

 

 

 

 

24

 

 

 

 

2

3

2

20

37

 

 

 

21

TO VALVE COVER

 

 

 

42

 

 

 

TO INTAKE

MANIFOLD

38

 

 

 

 

 

35

 

 

 

 

36

 

 

 

 

23

14

27

16

 

 

15

50 Generac® Power Systems, Inc.

Image 52
Contents 0046262, 0046263 Introduction Authorized Dealer LocationIntroduction Inside Front Cover General Hazards Electrical Hazards Prepackaged Transfer Switch UNPACKING/INSPECTIONGenerator Generator AC Connection SystemsMain Circuit Breaker SpecificationsEngine Protective Devices ‹ 1.8.2 Generator and Load Compatibility Fuel Requirements Recommendations‹ 1.9.1 Conversion to LP GAS Vapor Coolant Emissions Control System‹ 1.12.1 AIR Fuel Ratio Controller Standby Generator Installation Basic Standby Electric SystemNfpa Standards Other Published StandardsTransfer Switch Start Signal Connections ‹ 2.6.1 PRE-PACKAGED Type SwitchMethod Grounding the GeneratorPreparation Before START-UP Battery Installation‹ 2.7.1 Vented Batteries ‹ 2.8.2 Transfer Switch ‹ 2.8.1 Prior to Initial START-UP‹ 2.8.3 Fuel System ‹ 2.8.4 Generator SET LubricationUsing the AUTO/OFF/MANUAL Switch Engine Heater Sequence of Automatic Operation‹ 3.2.3 Manual Position Weekly Exercise Cycle Checking the Engine OIL LevelChanging the Engine AIR Cleaner ‹ 4.2.2 OIL and Filter Change ProcedureChanging the Engine OIL and Filter ‹ 4.2.1 Engine OIL Recommendations‹ 4.5.1 Battery Replacement Battery MaintenanceSpark Plugs Miscellaneous Maintenance Cooling SystemOverload Protection for DC Fuse‹ 4.11.1 Removal from Service OUT of Service Procedure‹ 4.11.2 Return to Service Service Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionElectrical Data TS1 Generator D4992-A Guardian Liquid- Panel 4.3L Drawing No Section Wiring Diagram Control Panel Model No KW Generators No D6975 EC1 ACT Drain Pan Oil QTY Description Base Frame Assembly M6 Hinge Panel Face Panel BTM & Back Control Exploded Views and Parts Lists Cover Plate AVR ALT Leads Sensing Wire QTY To Engine Flywheel Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists MOUNT, Engine R & L KIT Radiator Copper Brass DIA. Clamp Assembly 2 Compartment To Engine Front NUT Wing 1/4-20 Nylk To Stepper Motor Support Solenoid NAT GAS Attach to REGULATOR, N/G R600S Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper To Thermostat Housing Guardian Liquid-cooled 40 kW Generators Guardian Liquid-cooled 40 kW Generators MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule This Warranty Shall not Apply to the Following

0043735, 0043734, 0046262, 0046263, 0046264 specifications

Generac Power Systems has established itself as a leader in the power generation industry, best known for its wide range of products designed for various power needs. Among its offerings are model numbers 0043733, 0046264, 0046263, 0046262, and 0043734. Each unit reflects Generac's commitment to innovation, reliability, and efficiency in providing backup power solutions.

The Generac model 0043733 is a powerful portable generator known for its robust performance and user-friendly design. It typically features a high starting wattage, capable of powering essential appliances during outages. With a compact design and ergonomic handle, it ensures easy transportability, making it an excellent choice for outdoor activities or emergency backup. This model often incorporates advanced technology such as digital watt meters for real-time monitoring and fuel level indicators to enhance user convenience.

Moving on to model 0046264, this unit is engineered for reliability in home standby applications. Its automatic transfer switch allows for seamless switching from grid power to generator power in the event of an outage. This ensures a continuous power supply without any manual intervention. Generac's Quiet-Test technology makes this model exceptionally quiet, operating at a lower decibel level compared to traditional generators, enhancing its suitability for residential areas.

The 0046263 model is similar to the 0046264 but is designed for slightly different power requirements and configurations. It offers a range of customizable options, allowing users to tailor the system to their specific needs. Advanced monitoring capabilities often come standard, enabling users to track performance and receive alerts via smartphone or other devices.

Model 0046262 is also tailored for homeowners, focusing on versatility and efficiency. It usually features a highly efficient engine, capable of providing substantial power while optimizing fuel consumption. Its sturdy build ensures durability, making it suitable for various weather conditions.

Lastly, the 0043734 model is designed for commercial use, capable of handling larger power needs. It typically comes equipped with technologies such as remote monitoring and diagnostics, making it easier to maintain and service. With a heavy-duty construction, this model is built to withstand demanding environments while providing reliable, uninterrupted power.

In summary, Generac Power Systems offers a diverse range of backup power solutions through models such as 0043733, 0046264, 0046263, 0046262, and 0043734. With features focusing on portability, reliability, efficiency, and advanced technology, these models cater to various power requirements, ensuring customers can find the ideal generator for their needs.