Generac Power Systems 30, 20, 25 owner manual Miscellaneous Maintenance

Page 19

Standby Generator Sets

Maintenance

MISCELLANEOUS MAINTENANCE

‹CLEANING THE GENERATOR

Keep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen- erator windings have an adverse effect on insulation resistance.

Periodically clean generator exterior surfaces. A soft brush may be used to loosen caked on dirt. Use a vacuum system or dry, low pressure air to remove any accumulations of dirt. The generator is housed inside an all-weather enclosure, clean the enclosure with a soft, damp cloth or sponge and water.

Once each year have the generator cleaned and inspected by a Service Dealer. That dealer will use dry, low pressure air to clean internal windings. Parts inside the control console should be cleaned and inspected at this time as well.

Finally, have the insulation resistance of stator and rotor windings checked. If insulation resistances are excessively low, the generator may require drying.

‹BATTERY

All lead-acid storage batteries discharge when not in use. Refer to specific instructions and warnings that accompany the battery. If such information is not available, observe the following precautions when handling a battery:

DO NOT use jumper cables and a booster battery to crank or start the generator engine.

DO NOT recharge a weak battery while it is installed in the generator. Remove battery from generator and recharge in a well-ventilated area, away from fuel vapors, sparks, heat or flames.

Battery electrolyte fluid is an extremely caustic sulfuric solution that can cause severe burns. DO NOT permit fluid to contact eyes, skin, clothing, painted surfaces, wiring insulation, etc. If any bat- tery fluid is spilled, flush the affected area with clear water immediately.

Always wear safety glasses, rubber apron and gloves when handling a battery.

Batteries give off explosive hydrogen gas while charging. The gas can form an explosive mixture around the battery for several hours after charging. Any spark, heat or flames can ignite the gas and cause an explosion which can shatter the battery, causing blindness or other serious injury.

‹BATTERY MAINTENANCE

The battery should be inspected per the Scheduled Maintenance section. The following procedure should be followed for inspection:

1.Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary.

2.Check the battery fluid level of unsealed batteries and, if necessary, fill with DISTILLED WATER ONLY. DO NOT USE TAP WATER IN BATTERIES.

3.Have the state of charge and condition checked. This should be done with an automotive-type bat- tery hydrometer.

DANGER

Storage batteries give off explosive hydrogen gas. This gas can form an explosive mixture around the battery for several hours after charg- ing. The slightest spark can ignite the gas and cause an explosion. Such an explosion can shat- ter the battery and cause blindness or other injury. Any area that houses a storage battery must be properly ventilated. Do not allow smok- ing, open flame, sparks or any spark producing tools or equipment near the battery.

Battery electrolyte fluid is an extremely corro- sive sulfuric acid solution that can cause severe burns. Do not permit fluid to contact eyes, skin, clothing, painted surfaces, etc. Wear protective goggles, protective clothing and gloves when handling a battery. If fluid is spilled, flush the affected area immediately with clear water.

Do not use any jumper cables or booster battery to crank and start the generator engine. If the battery has completely discharged, remove it from the generator for recharging.

Be sure the AUTO/OFF/MANUAL switch is set to the OFF position, before connecting the battery cables. If the switch is set to AUTO or MANUAL, the generator can crank and start as soon as the battery cables are connected.

Be sure the 120VAC power supply to the battery is turned OFF, or sparking may occur at the bat- tery posts as the cables are attached and cause an explosion.

‹BATTERY REPLACEMENT

NOTE:

Unit DOES NOT include battery.

When supplying or replacing the battery, the recom- mended number and type of battery is listed in the Specifications Section.

NOTE:

The BCI number should be located directly on the battery.

‹REPAIR PARTS

The latter portion of this manual consists of exploded views, parts lists and electrical data pertaining to this generator set. The parts lists consist of (a) an item number, (b) a part number, (c) the quantity required, and (d) a description of the part. The item number corresponds to an identical number on the exploded view drawing.

06/07 D .Rev Maint011

10-4

Image 19
Contents 6L 20/25/30 kW Models Standby Generator Sets Table of Contents  Warning   Electrical Hazards  ‹ Read this Manual Thoroughly ‹ Operation and Maintenance‹ HOW to Obtain Service Introduction‹ Data Label Identification RecordEngine OIL Recommendations Equipment DescriptionCoolant Recommendations Engine Protective Devices ‹ LP Fuel System Fuel System‹ Fuel Requirements ‹ Natural GAS Fuel SystemSpecifications ‹ Cold Weather KIT ‹ Reconfiguring the Fuel SystemGenerator AC Lead Connections Alternator Power Winding Connections‹ FOUR-LEAD, SINGLE-PHASE Stator ‹ 3-PHASE AlternatorsPreparation Before START-UP InstallationInitial Inspection for Genset Startup ‹ Preparation for START-UP START-UP Checklist‹ Retransfer and Shutdown Operating Unit with Manual Transfer SwitchGenerator Control Operation ‹ Engine START-UP and TransferCooling System Maintenance Performed by Service FacilitiesChecking Fluid Levels ‹ Inspect Cooling System ‹ Battery Fluid‹ Check Battery ‹ Exercise System‹ Changing Engine OIL ‹ Changing the Engine AIR Cleaner ‹ Coolant Change‹ Spark Plugs Miscellaneous Maintenance Service Maintenance Interval Information Service ScheduleLevel Maintenance Level Problem Cause Correction Troubleshooting GuideStandby Generator Sets Standby Generator Sets Standby Generator Sets Standby Generator Sets Page Housing Blower LG Pilot Page Screw Phtt M4-0.7 X 12 ZYC Page Components Included in 0G4577E Page Radiator Support LH Side 1.6L Page Mounting Base 1.6L 2007 C1 Page Battery TRAY, C1 & C2 Page Engine Generac 1.6L NG Page ASM Motor Stepper Page Elbow 90D 3/4 NPT Page Rear Intake Wrap 1.6L C1 Page Muffler C1 Page Page Page Page Page Page Page Page Page Page Page Page Page Page 04/07 a .Rev BackPg001

25, 30, 20 specifications

Generac Power Systems is a leading manufacturer of backup power generation products and tools, known for their reliability and innovation. Among their diverse lineup are the Generac 20kW, 25kW, and 30kW home standby generators. These models are designed to provide seamless power during an outage, allowing homeowners to maintain their everyday activities without interruption.

The Generac 20kW generator is particularly popular for residential use. It can power essential circuits as well as larger appliances, making it an ideal choice for homes with moderate electricity needs. One of its standout features is the Smart Management Module, which allows homeowners to manage energy consumption effectively, ensuring that they can run necessary appliances without overwhelming the system. Additionally, the 20kW generator is equipped with a durable enclosure, offering long-lasting protection against the elements.

Moving up in capacity, the Generac 25kW model caters to homes with higher electricity demands. This generator combines efficiency with strength, providing enough power for a wider range of home appliances and systems. It features a TruePower Technology that delivers clean power, crucial for sensitive electronics. Moreover, the 25kW model operates quietly, contributing to a comfortable home environment even during power outages.

The Generac 30kW generator is designed for larger homes or light commercial applications. It provides an impressive power output while maintaining high efficiency. Its features include advanced digital control, allowing for easy monitoring and maintenance. The 30kW model also offers an automatic transfer switch, which ensures that power is restored quickly and safely when utilities fail.

All three models utilize Generac's G-Force engine, known for its low maintenance requirements and high performance. They come with a five-year limited warranty, providing peace of mind for users. Furthermore, with Wi-Fi monitoring capabilities, homeowners can keep track of their generator's status from anywhere, ensuring they are always prepared for any power interruption.

In summary, the Generac 20kW, 25kW, and 30kW generators are excellent options for homeowners seeking reliable backup power. Their advanced features, durable construction, and efficient operation make them stand out in the market. Whether for essential home use or larger applications, Generac's lineup delivers dependable performance and innovative technology.