Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Wiring Diagram – 12 & 15 kW – Drawing No. 0D8500-B

DIAGRAM KEY

BA - BRUSH ASSEMBLY

BCR - BATTERY CHARGE RELAY

CB1 - MAIN OUTPUT BREAKER

CB2 - CIRCUIT BREAKER, ALTERNATOR EXCITATION

D - DIODE

DSW - PCB MOUNTED DIP SWITCH FS - FUEL SOLENOID

F1 - FUSE 15 AMP

F2 - FUSE 5 AMP

GRD - CONTROL PANEL GROUND HTO - HIGH OIL TEMPERATURE SWITCH IC - INLINE CONNECTOR

ICT - INTERCONNECTION TERMINALS

IM1 - IGNITION MODULE, CYLINDER #1

IM2 - IGNITION MODULE, CYLINDER #2

LOP - LOW OIL PRESSURE SWITCH SC - STARTER CONTACTOR

SCR - STARTER CONTACTOR RELAY SP1, SP2 - SPARK PLUGS

SW1 - AUTO / OFF / MANUAL SWITCH SW2 - SET EXERCISE SWITCH

SM - STARTER MOTOR

TB - INSULATED TERMINAL BLOCK

TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA (DUAL SEC.)

ENGINE WIRING

3

 

 

 

 

 

 

 

 

2

BATTERY

 

 

 

1

 

 

 

 

CHARGER

 

 

14

 

 

2

 

0

 

 

 

 

 

 

1

 

 

 

 

 

225B

FS

 

224B

 

 

 

 

 

 

13A

 

13A

0

0

0

 

 

 

225B

 

 

 

224B

 

 

 

 

 

 

 

14

0

0

14

 

 

 

 

14

 

 

 

 

IC

SP1

D

 

 

 

 

IM1

 

SP2

D

IC

 

IC

IM2

85

HTO

0

86

LOP

0

TB

0 6 0

18

14

85 4

86 3

13

13

 

 

 

 

 

 

 

 

1

16

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

C1

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

SCR

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

A

B

 

 

 

 

 

 

 

86

 

 

 

351

 

 

 

 

 

 

 

 

 

 

 

 

56

0

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

 

 

16

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

86

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

 

5

 

 

 

 

 

 

 

 

 

 

J2

 

 

 

 

 

 

 

 

 

 

 

 

 

J1

 

CONTROL

 

 

 

 

 

 

 

PRINTED CIRCUIT BOARD

 

 

18

56

1

4

 

2

 

3

23

 

4

 

5

56

 

6

 

7

14

 

8

 

13

13

351

18

56 14

86

194

18

66A

BLACK

RED

 

DSW

SM

1 - 20 Vac Sense Transformer

9

239

 

10

 

11

17

12

 

13

0

14

 

15

224

15A

15

225

+

12V

BATTERY

CUSTOMER SUPPLIED

2 - Remote Not Auto

3 - 50 Hz Operation

4 - SPARE

SC

L.E.D - ALARM INDICATORS

16

17

24 Generac® Power Systems, Inc.

Image 26
Contents Installation Introduction Troubleshooting Post Installation Start-up AdjustmentsMaintenance Introduction Inside Front CoverGeneral Hazards Electrical Hazards ‹ Standards IndexSystem SET LED UNPACKING/INSPECTIONProtection Systems Generator 7 kW, Single Cylinder GH-410 Engine‹ 1.5.2 Engine Specifications‹ 1.5.1 Generator Fuel Consumption Reconfiguring the Fuel SystemFuel Requirements Recommendations 1 7 KW, 410CCGenerator Transfer SwitchLocation 2.1 7 kW, 12 kW and 15 kW UnitsBattery Installation BatteryElectrical Checks Check Transfer Switch OperationBefore Initial START-UP Generator Tests Under Load Checking Automatic Operation1 7 KW Units Adjusting the Regulator Natural GAS onlyEngine Governor Adjustment 2 12 KW and 15 KW Units Voltage Regulator AdjustmentBREAK-IN Procedure ‹ 3.2.1 Auto Position Automatic Transfer OperationSequence of Automatic Operation ‹ 3.2.2 OFF Position‹ 3.5.2 Transfer Back to Utility Power Source Manual Transfer Operation‹ 3.7.2 High Temperature Switch Setting the Exercise Timer‹ 3.7.1 LOW OIL Pressure Switch ‹ 3.7.3 Overcrank‹ 4.3.1 Engine OIL Recommendations Checking the Engine OIL LevelChanging the Engine OIL ‹ 4.5.1 7 KW, 12 KW and 15 KW Generators ‹ 4.3.2 OIL Change ProcedureChanging the OIL Filter Battery Maintenance Spark PlugsAdjusting Valve Clearance Cooling System‹ 4.12.1 Removal from Service OUT of Service Procedure‹ 4.12.2 Return to Service Corrosion ProtectionService Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionElectrical Data Customer Battery SCR Electrical Data Connection BCR SW1 Exploded Views and Parts Lists Part NO.QTY. Description Exploded Views and Parts Lists Part NO. QTY. Description 140 Part NO. QTY Description Exploded Views and Parts Lists QTY Description 14 20 ADAPTOR, Engine Exploded Views and Parts Lists Stator 12KW Exploded Views and Parts Lists PIN, Piston D20 Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome For GT 760 Engine only CASTING, Twin Regulator Housing Mounting Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators California and Federal Emission Control Warranty Statement Emission Control System Warranty Warranty Schedule

04758-1, 04759-1, 04760-1 specifications

Generac Power Systems is a leading manufacturer of power generation equipment, particularly known for its innovative solutions in backup and portable power. Among its impressive product lineup, the Generac models 04758-1, 04759-1, and 04760-1 stand out for their reliability and advanced features, making them ideal choices for residential and commercial applications.

The Generac 04758-1 is a robust standby generator that delivers a powerful output of 22kW. It is designed to automatically kick in during power outages, ensuring that homes remain powered without the need for manual intervention. One of its main features is the innovative Mobile Link app, which allows users to monitor their generator's status remotely through their smartphones. This model also incorporates Generac's G-Force engine, which is designed with durability in mind, providing longer run times and enhanced performance.

The 04759-1 model builds on its predecessor's strengths by enhancing its power capabilities. With a 24kW output, it efficiently supplies power to larger homes or small businesses that require reliability during outages. Its True Power Technology ensures clean power output, making it suitable for sensitive electronics. The 04759-1 also boasts advanced diagnostic features, allowing for self-testing and maintenance alerts, which contribute to its user-friendly design.

Moving up in the lineup, the Generac 04760-1 generator further amplifies power output, reaching an impressive 26kW. This model is tailored for those who demand the utmost in power reliability, featuring an aluminized steel enclosure that enhances durability and rust resistance. The 04760-1 is equipped with Wi-Fi connectivity, enabling real-time updates and notifications directly to users’ mobile devices. Its superior sound attenuated design operates quietly, ensuring minimal disruption during operation.

All three models are equipped with the Quiet-Test technology, which allows for a low-decibel exercise cycle that reduces noise levels without sacrificing performance. Additionally, Generac back them with a comprehensive warranty and customer support, assuring consumers of their long-term reliability and effectiveness. With advanced features, superior performance, and innovative technology, the Generac 04758-1, 04759-1, and 04760-1 models offer dependable solutions for power generation needs, catering to a diverse range of applications while ensuring peace of mind during power interruptions.