Echo PB-250 manual Remove blower pipes, Operation, Fuel

Page 10

10

remove blower pipes

Tools required: Screwdriver

1.Insert screwdriver (F) into hole located near lock symbol (G) to release pipe lock.

Caution

Screwdriver tip may stick out opposite side of locking hole.

2.Pull pipe out of fan case.

3.Remove screwdriver.

G

F

Operation

WARNING

Moving parts can amputate fingers or cause severe injuries. Keep hands, clothing and loose objects away from all openings. Always stop engine, disconnect spark plug, and make sure all moving parts have come to a complete stop before removing obstructions, clearing debris, or servicing unit. Blower housing may contain shredder blades and other sharp edges that can cause serious injuries if touched, even if engine is off and blades are not moving. Wear gloves to protect hands from sharp edges and hot surfaces.

WARNING

Operation of this equipment may create sparks that can start fires around dry vegetation. This unit is equipped with a spark arrestor and a spark arrestor may be required. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements.

fuel

NOTICE: Use of unmixed, improperly mixed, or fuel older than 90 days, (stale fuel), may cause hard starting, poor

performance, or severe engine damage and void the product warranty. Read and follow instructions in the Storage section of this manual.

WARNING

Alternative fuels, such as E-15 (15% ethanol), E-85 (85% ethanol) or any fuels not meeting ECHO requirements are

NOT approved for use in ECHO 2-stroke gasoline engines. Use of alternative fuels may cause performance prob-

lems, loss of power, overheating, fuel vapor lock, and unintended machine operation, including, but not limited to, improper clutch engagement. Alternative fuels may also cause premature deterioration of fuel lines, gaskets, carbu- retors and other engine components.

Image 10
Contents Power Blower Introduction Table of ContentsOperators manual International symbols Safety Manual safety symbols and important informationPersonal condition and safety equipment Hand Protection Physical ConditionEye Protection Breathing ProtectionClear the Work Area Repetitive Stress InjuriesRead the Manuals Keep a Firm GripEquipment check EPA 2010 and Later and/or C.A.R.B. TierEmission Control exhaust & evaporative General Warning Decal located on blower housing DescriptionContents Assembly Install blower pipesOperation Remove blower pipesFuel Fuel Requirements Handling FuelStarting cold engine Purge BulbStarting warm engine Stopping engineOperating blower Maintenance intervals MaintenanceSkill level Air filter Fuel filterSpark plug Cooling systemSpark Arrestor Screen Exhaust systemExhaust Port Cleaning Engine Break-In Carburetor adjustmentHigh Altitude Operation Power Blower Operators Manual Long Term Storage Over 30 Days StorageSpecifications Model PB-250 Hand HeldWarranty Statements Exceptions99922201032 12/03/09 01/2010 Power Blower Operators Manual Servicing Information parts/serial number ServiceWarranty registration Additional or replacement manuals Echo consumer product support