Echo PB-250 manual Skill level, Maintenance intervals

Page 15

Power Blower 15

Operator's Manual

Maintenance

WARNING

Moving parts can amputate fingers or cause severe injuries. Keep hands, clothing and loose objects away from all

openings. Always stop engine, disconnect spark plug, and make sure all moving parts have come to a complete stop before removing obstructions, clearing debris, or servicing unit. Allow unit to cool before performing service. Wear gloves to protect hands from sharp edges and hot surfaces.

Your ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help your blower achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your unit to an ECHO Service Dealer for maintenance. To help you decide whether you want to DO-IT-YOURSELF or have the ECHO Dealer do it, each maintenance task has been graded. If task is not listed, see your ECHO Dealer for repairs.

skill level

Level 1 = Easy to do. Common tools may be required.

Level 2 = Moderate difficulty. Some specialized tools may be required.

ECHO offers REPOWERTM Maintenance Kits and Parts to make your maintenance job easier.

maintenance intervals

 

MainTEnanCE

rEQ'D

DaiLY Or

EVErY

3 MOnTHS

YEarLY

COMPOnEnT / SYSTEM

SKiLL

Or 90

PrOCEDUrE

BEFOrE USE

rEFUEL

600 HOUrS

 

LEVEL

HOUrS

 

 

 

 

 

Air Filter

Inspect/Clean

1

I / C *

 

R *

 

Choke Shutter

Inspect/Clean

1

I / C

 

 

 

Fuel Filter

Inspect/Replace

1

 

 

I *

I / R *

Fuel Cap Gasket

Inspect/Replace

1

 

 

I *

R *

Fuel System

Inspect/Replace

1

I (1) *

I (1) *

 

 

Spark Plug

Inspect/Clean/Replace

1

 

 

I / C / R *

 

Cooling System

Inspect/Clean

2

I / C

 

 

 

Muffler Spark Arrestor

Inspect/Clean/Replace

2

 

 

I / C / R *

 

 

 

 

 

 

 

 

Cylinder Exhaust Port

Inspect/Clean/Decarbon

2

 

 

I / C

 

 

 

 

 

 

 

 

Recoil Starter Rope

Inspect/Clean

1

I / C *

 

 

 

Screws/Nuts/Bolts

Inspect/Tighten/Replace

1

I *

 

 

 

MainTEnanCE PrOCEDUrE LETTEr CODES: i = inSPECT,

r = rEPLaCE, C = CLEan

 

iMPOrTanT nOTE - Time intervals shown are maximum. Actual use and your experience will determine the frequency of required maintenance.

MainTEnanCE PrOCEDUrE nOTES:

(1)Low evaporative fuel tanks DO NOT require regular maintenance to maintain emission integrity. * All recommendations to replace are based on the finding of damage or wear during inspection.

Image 15
Contents Power Blower Table of Contents IntroductionOperators manual Safety Manual safety symbols and important information International symbolsPersonal condition and safety equipment Breathing Protection Physical ConditionEye Protection Hand ProtectionKeep a Firm Grip Repetitive Stress InjuriesRead the Manuals Clear the Work AreaEPA 2010 and Later and/or C.A.R.B. Tier Equipment checkEmission Control exhaust & evaporative Description General Warning Decal located on blower housingContents Install blower pipes AssemblyRemove blower pipes OperationFuel Handling Fuel Fuel RequirementsPurge Bulb Starting cold engineStopping engine Starting warm engineOperating blower Maintenance Maintenance intervalsSkill level Fuel filter Air filterCooling system Spark plugExhaust system Spark Arrestor ScreenExhaust Port Cleaning Carburetor adjustment Engine Break-InHigh Altitude Operation Power Blower Operators Manual Storage Long Term Storage Over 30 DaysModel PB-250 Hand Held SpecificationsExceptions Warranty Statements99922201032 12/03/09 01/2010 Power Blower Operators Manual Echo consumer product support ServiceWarranty registration Additional or replacement manuals Servicing Information parts/serial number