Echo PB-250 manual Starting warm engine, Stopping engine

Page 13

Power Blower 13 Operator's Manual

starting warm engine

The starting procedure is the same as Cold Start except DO NOT close the choke.

1.Stop Switch

Move stop switch button (A) away from the STOP position.

2.Throttle Position Lever

Move throttle position lever (B) midway between idle and full throttle positions.

3.Purge Bulb

Pump purge bulb (D) until fuel is visible and flows freely in the clear fuel tank return line.

4.Recoil Starter

Place the unit on a flat, clear area. Firmly grasp throttle grip with left hand and rapidly pull recoil starter handle/rope (E) until en- gine fires.

A

B

D

IMPORTANT

Recoil starter: Use short pulls - only 1/2 ~ 2/3 of rope for start- ing. Do not allow the rope to snap back in. Always hold the unit firmly.

NOTE

If engine does not start after 5 pulls, use Cold Start Procedure.

E

stopping engine

1.Throttle Trigger/Throttle Position Lever

Release throttle trigger (F). Move throttle position lever (B) forward to idle position and allow engine to return to idle before shutting off engine.

2.Stop Switch

Move stop switch (A) to “STOP” position.

warning

If engine does not stop when stop switch is moved to STOP posi- tion, close choke - COLD START ( ) position - to stall engine. Have your ECHO dealer repair stop switch before using blower again.

 

A

B

F

Image 13
Contents Power Blower Introduction Table of ContentsOperators manual International symbols Safety Manual safety symbols and important informationPersonal condition and safety equipment Eye Protection Physical ConditionHand Protection Breathing ProtectionRead the Manuals Repetitive Stress InjuriesClear the Work Area Keep a Firm GripEquipment check EPA 2010 and Later and/or C.A.R.B. TierEmission Control exhaust & evaporative Description General Warning Decal located on blower housingContents Install blower pipes AssemblyOperation Remove blower pipesFuel Handling Fuel Fuel RequirementsPurge Bulb Starting cold engineStopping engine Starting warm engineOperating blower Maintenance intervals MaintenanceSkill level Fuel filter Air filterCooling system Spark plugExhaust system Spark Arrestor ScreenExhaust Port Cleaning Engine Break-In Carburetor adjustmentHigh Altitude Operation Power Blower Operators Manual Storage Long Term Storage Over 30 DaysModel PB-250 Hand Held SpecificationsExceptions Warranty Statements99922201032 12/03/09 01/2010 Power Blower Operators Manual Warranty registration Additional or replacement manuals ServiceServicing Information parts/serial number Echo consumer product support