CARE AND MAINTENANCE
HYDROSTAT OIL MAINTENANCE PROCEDURE
Check the oil level in hydrostatic transmission oil reservoir after every 25 hours of usage. Clean the oil reservoir cap and the area around it prior to removal. Check the oil level. Oil should be approximately ¼” below top of oil tank baffle. Replenish as needed with
Change the oil in the reservoir and hydrostat transmission oil filter after the first 100 hours of use and then every 500 hours. Remove the filter and be sure all oil has drained from the reservoir. Replace with a new OEM filter
(P/N 539 121763) and
¼" (6mm)
| È |
| Ç |
Baffle | Oil Level |
|
Please dispose of used oils at proper collection centers.
Protect your environment.
41