SAFETY

WARNING!

The engine must not be started when the driver’s floor plate or any protective plate for the mower deck’s drive belt is removed.

Safe Handling of Gasoline

To avoid personal injury or property damage, use extreme care in handling gasoline. Gasoline is extremely flammable and the vapors are explosive.

Extinguish all cigarettes, cigars, pipes, and other sources of ignition.

Use only approved gasoline container.

Never remove gas cap or add fuel with the engine running. Allow engine to cool at least two (2) minutes before refueling.

Never fuel the machine indoors.

Never store the machine or fuel container where there is an open flame, spark, or pilot light such as on a water heater or other appliance.

Before beginning to refuel, minimize the risk of static electricity by touching a metal surface.

Never fill containers inside a vehicle or on a truck or trailer bed with plastic liner. Always place containers on the ground away from the vehicle when filling.

Remove gas-powered equipment from the truck or trailer and refuel it on the ground. If this is not possible, refuel such equipment with a portable container, rather than from a gasoline dispenser nozzle.

Keep the nozzle in contact with the rim of the fuel tank or container opening at all times until fueling is complete. Do not use a nozzle lock-open device.

If fuel is spilled on clothing, change clothing immediately.

Never overfill fuel tank. Replace gas cap and tighten securely.

Do not start the engine near spilled fuel.

Never use gasoline as a cleaning agent.

If leaks arise in fuel system, engine must not be started until problem has been resolved.

Check the fuel level before each use and leave space for the fuel to expand, as the heat from the engine and the sun may otherwise cause the fuel to expand and overflow.

8011-516

Never fill the fuel tank indoors

WARNING!

The engine and the exhaust system become very hot during operation.

There is risk for burns if touched.

Allow engine and exhaust system to cool at least two (2) minutes before refueling.

13

Image 13
Contents Operator Manual Page Table of Contents Page Introduction Manufacturing Number Good ServiceSymbols and decals Manual Performing any Safety Instructions SafetyGeneral Operation Never take passengers Slope Operation Personal Safety EquipmentChildren Safe Handling of Gasoline General Maintenance Risk of sparking Spark Arrestor TransportControl Locations ControlsMotion Control Levers Bypass Linkage Seat Adjustment LeverUnlocking Transmission Fuel Tank Choke Control Ignition SwitchThrottle Control Cutting Height Adjuster Blade SwitchParking Brake Always use the high position to transportFuel Shut Off Valve FusesSteering TrainingStarting the Engine Before StartingPlace controls in neutral position USE Full Throttle When Mowing To remove cables, reverse order Weak BatteryRunning Mower deck’s anti-scalp rollers should be evenly adjustedOperating On Hills Mowing Tips Stopping the Engine Manual Transport Maintenance Schedule MaintenanceBefore After Year 100 Replacing battery BatteryTire Pressures Safety SystemDeck Belt Faulty adjustment can cause an accidentDeck Belt Removal EZT Belt Installation Deck Belt InstallationPump Belt Replacing EZT E-Series Zeroturn Transaxle beltCutting Blades Blade replacementAnti-scalp Rollers Deck Leveling Adjusting the Mower DeckUse protective glasses when cleaning and washing CleaningCaster Wheels HardwareLubrication Schedule LubricationGeneral Front Wheel Mount Wheel and Deck ZerksFront Wheel Bearings Deck SpindlesProblem Cause Trouble ShootingMaintenance section Trouble Shooting Storage ServiceWinter Storage Schematic Torque Specifications Technical DataHex Head Cap Screws Standard HardwareTransmission 966496201 966883101 Engine966496201 965883101 Equipment Overall dimensionsProductivity 965883201 Engine 965883201 USA requirements Conformity CertificatesCE requirements Dixon ZTR Residential WarrantyDelivery Service Service JournalAction Stamp, signAfter 10 hours Daily ServiceHour Service Service Journal At least once each year Action Date, mtr reading Stamp, sign Service Journal Page 115 337627R1 11/16/09

965883201, 965883101, 966496301, 54BF, 42BF specifications

The Dixon 46BF,966496201,42BF,54BF,966496301 is a remarkable technological advancement in the realm of machinery and instrumentation. This model combines cutting-edge features with robust performance capabilities, catering to diverse industrial applications.

One of the standout features of the Dixon 46BF series is its high efficiency. Designed with advanced aerodynamics, it optimizes energy consumption while ensuring peak performance. The incorporation of the latest engine technologies enhances fuel efficiency, making it a cost-effective option for businesses looking to reduce operational costs without compromising on power.

Safety is a paramount consideration in the design of the Dixon 46BF model. It comes equipped with state-of-the-art safety features that minimize the risk of accidents during operation. This includes advanced sensor systems that monitor various parameters in real-time, ensuring that any deviations from the standard operating conditions are promptly addressed.

The construction of the Dixon 46BF series emphasizes durability. Made from high-quality materials, it is engineered to withstand demanding environments, minimizing wear and tear. This investment in quality ensures longevity, reducing the need for frequent repairs or replacements.

Moreover, the Dixon 46BF series incorporates smart technology into its design. With connectivity options, it can be integrated into existing digital infrastructures. This allows for remote monitoring and control, enabling operators to manage their machinery from virtually anywhere, enhancing operational flexibility and responsiveness.

Another characteristic that sets the Dixon 46BF apart is its customization capabilities. Clients can choose from various options tailored to their specific needs, whether it’s adjusting performance parameters or selecting additional features. This level of customization ensures that the machinery aligns perfectly with individual operational requirements.

In terms of maintenance, the Dixon 46BF is designed with user-friendliness in mind. Simplified access to key components facilitates quicker servicing, reducing downtime and improving overall productivity.

Overall, the Dixon 46BF,966496201,42BF,54BF,966496301 is a blend of innovation, efficiency, and reliability, making it an excellent choice for companies seeking a solution that meets modern industrial challenges while ensuring sustainability and safety. With its array of features and technologies, it stands as a benchmark in industrial machinery, poised to lead the future of operational excellence.