Dixon 42BF, 46BF, 965883201, 965883101, 54BF, 966496201, 966496301 manual Risk of sparking

Page 15

SAFETY

Sparking can occur when working with the battery and the heavy cables of the starter circuit. This can cause battery explosion, fire or eye injury. Sparking in this circuit can not occur after the chassis cable (normally negative, black) is removed from the battery.

Use protective goggles.

Ensure that the fuel filler cap is mounted tightly and no flammable substances are stored in an open vessel.

WARNING!

Avoid electrical sparking and its consequences by the following routines:

Never work with the starter circuit if there is spilled fuel.

Disconnect the negative cable from the battery first and reconnect it last.

Do not make a bridge short circuit across the starter relay to run the starter.

Never use the machine indoors or in spaces lacking proper ventilation. The exhaust fumes contain carbon monoxide, an odorless, poisonous, and lethal gas.

Stop to inspect the equipment if the machine runs over or into anything. If necessary, make repairs before starting.

Never make adjustments with the engine running.

The machine is tested and approved only with the equipment originally provided or recommended by the manufacturer. Only use approved repair parts for the machine.

The blades are sharp and can cause cuts and gashes. Wrap the blades or use protective gloves when handling them.

Check the parking brake’s functionality regularly. Adjust and service as necessary.

The mulch blades should only be used in familiar areas when higher quality mowing is desired.

Reduce the risk of fire by removing grass, leaves, and other debris that may have accumulated on the machine.

Allow the machine to cool before putting it in storage.

Regularly clean deck and underside of deck, avoid spraying engine and electrical components with water.

6003-009

Do not smoke when performing maintenance on the battery. The battery can explode and cause serious injury/damage.

8009-728

Risk of sparking

8011-514

Regularly clean deck

15

Image 15
Contents Operator Manual Page Table of Contents Page Introduction Manufacturing Number Good ServiceSymbols and decals Manual Performing any Safety Safety InstructionsGeneral Operation Never take passengers Slope Operation Personal Safety EquipmentChildren Safe Handling of Gasoline General Maintenance Risk of sparking Spark Arrestor TransportControl Locations ControlsMotion Control Levers Seat Adjustment Lever Bypass LinkageUnlocking Transmission Fuel Tank Ignition Switch Choke ControlThrottle Control Always use the high position to transport Blade SwitchCutting Height Adjuster Parking BrakeFuel Shut Off Valve FusesSteering TrainingStarting the Engine Before StartingPlace controls in neutral position USE Full Throttle When Mowing To remove cables, reverse order Weak BatteryRunning Mower deck’s anti-scalp rollers should be evenly adjustedOperating On Hills Mowing Tips Stopping the Engine Manual Transport Maintenance Schedule MaintenanceBefore After Year 100 Replacing battery BatteryTire Pressures Safety SystemFaulty adjustment can cause an accident Deck BeltDeck Belt Removal Replacing EZT E-Series Zeroturn Transaxle belt Deck Belt InstallationEZT Belt Installation Pump BeltBlade replacement Cutting BladesAnti-scalp Rollers Deck Leveling Adjusting the Mower DeckHardware CleaningUse protective glasses when cleaning and washing Caster WheelsLubrication Lubrication ScheduleGeneral Deck Spindles Wheel and Deck ZerksFront Wheel Mount Front Wheel BearingsTrouble Shooting Problem CauseMaintenance section Trouble Shooting Service StorageWinter Storage Schematic Standard Hardware Technical DataTorque Specifications Hex Head Cap ScrewsTransmission 966496201 966883101 EngineOverall dimensions 966496201 965883101 EquipmentProductivity 965883201 Engine 965883201 Conformity Certificates USA requirementsCE requirements Dixon ZTR Residential WarrantyStamp, sign Service JournalDelivery Service ActionAfter 10 hours Daily ServiceHour Service Service Journal At least once each year Action Date, mtr reading Stamp, sign Service Journal Page 115 337627R1 11/16/09

965883201, 965883101, 966496301, 54BF, 42BF specifications

The Dixon 46BF,966496201,42BF,54BF,966496301 is a remarkable technological advancement in the realm of machinery and instrumentation. This model combines cutting-edge features with robust performance capabilities, catering to diverse industrial applications.

One of the standout features of the Dixon 46BF series is its high efficiency. Designed with advanced aerodynamics, it optimizes energy consumption while ensuring peak performance. The incorporation of the latest engine technologies enhances fuel efficiency, making it a cost-effective option for businesses looking to reduce operational costs without compromising on power.

Safety is a paramount consideration in the design of the Dixon 46BF model. It comes equipped with state-of-the-art safety features that minimize the risk of accidents during operation. This includes advanced sensor systems that monitor various parameters in real-time, ensuring that any deviations from the standard operating conditions are promptly addressed.

The construction of the Dixon 46BF series emphasizes durability. Made from high-quality materials, it is engineered to withstand demanding environments, minimizing wear and tear. This investment in quality ensures longevity, reducing the need for frequent repairs or replacements.

Moreover, the Dixon 46BF series incorporates smart technology into its design. With connectivity options, it can be integrated into existing digital infrastructures. This allows for remote monitoring and control, enabling operators to manage their machinery from virtually anywhere, enhancing operational flexibility and responsiveness.

Another characteristic that sets the Dixon 46BF apart is its customization capabilities. Clients can choose from various options tailored to their specific needs, whether it’s adjusting performance parameters or selecting additional features. This level of customization ensures that the machinery aligns perfectly with individual operational requirements.

In terms of maintenance, the Dixon 46BF is designed with user-friendliness in mind. Simplified access to key components facilitates quicker servicing, reducing downtime and improving overall productivity.

Overall, the Dixon 46BF,966496201,42BF,54BF,966496301 is a blend of innovation, efficiency, and reliability, making it an excellent choice for companies seeking a solution that meets modern industrial challenges while ensuring sustainability and safety. With its array of features and technologies, it stands as a benchmark in industrial machinery, poised to lead the future of operational excellence.