HYDROSTAT OIL MAINTENANCE PROCEDURE:

Check the oil level in hydrostatic transmisison oil reser- voir after every 25 hours of usage. Clean the oil reser- voir cap and the area around it prior to removal. Check the oil level. Oil should be approximately 1-3/8” below top of oil tank. Replenish as needed with SAE 20W-50 motor oil. DO NOT OVERFILL. When checking the oil level, be very careful to keep the reservoir clean.

Change the oil in the reservoir and hydrostat transmis- sion oil filter after the first 100 hours of use. Then every 500 hours after that. Remove the filter and be sure all oil has drained from the reservoir. Replace with a new OEM filter (P/N 7252) and SAE 20W-50 motor oil.

Please dispose of used oil at proper collection centers -

protect your environment

34

Image 34
Contents Model Important Read Carefully D E Safety Safety Alert Symbol General Operation General Operation Slope Operation Do not mow itDo not Children Service Service Dixon Limited Warranty Policy Specification S Seat Adjustment Instructions Controls Control Levers To GO ForwardParking Brake Choke Control LeverThrottle Control Lever Hydraulic Drive SystemBlade Drive Mower Deck CUT Height Lift LeverOperation Instructions Before Operating Mower Testing of Safety Interlock Systems Blade Drive Switch Test Electric Clutch Starting Instructions cold engine Starting Instructions engine has been operated Maintain Sharp Blades hroughout The Cutting Season Grass Height and Cutting Suggestions To Free Wheel Machine Unlock Transmission Care and Maintenance G I N E Mower Blades Hydrostatic Transmissions LubricationBelts Electrical Systems Hydrostat OIL Maintenance Procedure Procedure for Raising and Lowering the Deck for Servicing Positionoperation Inshown Mower Mower Shown in Servicing Position Leveling the Deck Standard Service Parts List Model ZTRTroubleshooting Engine Overheated Page Owner F O R M a TI O N ZTRMowers