4.OPERATING INSTRUCTIONS

Configuring the Starting Address

Each fixture requires a starting address from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the starting address. For example, a fixture that uses seven DMX channels and is addressed to start on DMX channel 100, will read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose the starting addresses for each fixture so that the channels used do not overlap. In addition, you should note the starting address selected for future reference. The LED Par 64-36VW B/C fixture uses two or four DMX channels. If you are unfamiliar with DMX, download the DMX Primer from www.chauvetlighting.com.

Control Panel Functions

Access control panel functions using the four buttons located directly underneath the LED display on the control panel.

BUTTON

FUNCTION

 

Used to scroll through the

<MENU>

current operating mode,

as well as back out of the

 

 

current menu option

 

 

<UP>

Used to select increasing

advancement in the value

 

<DOWN>

Used to select decreasing

advancement in the value

 

 

 

<ENTER>

Used to select a value and

store it to memory

 

MENU UP DOWN ENTER

The Control Panel shows the current state of the unit. It is used to select the operating mode, as well as the sub-features. For a detailed layout of the control panel functions, please see the “menu map” section on the following page.

Menu Map

MAIN

 

 

 

 

 

FUNCTION

 

SUB-FUNCTION

SELECTION

SUB-SELECTION

INSTRUCTION

 

 

P1

3 Color Switching

 

Select between 1 switching and 1

 

 

P2

3 Color fading

-

fading auto programs (Use S--to

P--

 

 

modify the speed)

 

 

 

Use the Audio

 

 

 

P3

 

 

 

 

3 Color Switching

Adjustment Knob located

Sound-Active program

 

 

 

 

on the back of the fixture

 

2-CH

 

d001~d512

-

-

Select 2-channel DMX mode: warm

 

white, cool white

4-CH

 

d001~d512

 

 

Select 4-channel DMX mode:

 

-

-

master dimmer, warm white, cool

 

 

C1

 

 

white, strobe

 

 

Warm White

 

Select between 3 static colors. The

C--

 

C2

Cool White

-

display will read C1~C3. The

 

colors that each of these represent

 

 

C3

Warm and Cool White

 

 

 

 

are indicated to the left.

S--

 

S001~S100

(default range is S050)

-

This is the speed range for the 2

 

switching and fading built-in

 

 

r---

 

 

programs

U--

 

Warm White

000~100

Combine warm white and cool white

 

C---

Cool White

to create a custom, static color

 

 

 

LED Par 64-36VW B&C User Manual

9

Rev. 4

Image 9
Contents LED Par 64-36VWB LED Par 64-36VWC Snapshot Table of Contents Before YOU Begin What is IncludedUnpacking Instructions Manual ConventionsFeatures Safety InstructionsAdditional Features IntroductionProduct Overview Product Overview Setup AC PowerPower Linking Orientation MountingOperating Instructions Configuring the Starting Address Control Panel FunctionsMenu Map Menu UP Down EnterDMX Operation Master/SlaveStandalone Operation Setting the Starting Address DMX Channel ValuesCustom Static Color Mixing Setting up a DMX Serial Data Link AppendixFixture Linking General Troubleshooting General MaintenanceDMX Claims Return ProcedureContact Us Technical SpecificationsLEDPAR6436VWB LEDPAR6436VWC