Inteli•Touch™
TROUBLESHOOTING
Before Requesting Service: Please follow this troubleshooting guide be- fore contacting your dealer for assistance.
Caring for Finishes: For cleaning, a soft brush or
in the same manner.
Blades: Wood finish blades should be cleaned with a furniture polishing cloth. Occasionally, a light coat of furniture polish may be applied for added protection and beauty.
Never Lubricate this Fan!
The precision motor at the heart of your Casablanca fan features sealed bearings that are lubricated for life. Do not attempt to oil the motor.
Changing Light Bulbs
Be sure to turn power to the fan OFF at the wall switch or circuit
breaker before changing light bulbs. Replace bulbs with same type as removed from the fixture. Each fan is rated for a maximum TOTAL
wattage of lighting.
Exceeding the rated maximum allowable wattage for the fan will burn out the fan electronics module and void the warranty.
PROBLEMINTELI•TOUCH POSSIBLE REMEDIES
NO FAN OR LIGHT Check main circuit fuses, curcuit breakers, or wall switch position. Check all wire connections, making sure the power is turned off during this inspection.
FAN WOBBLES OR SHAKES Be sure canopy pin is properly set into the slot on the ball
EXCESSIVELY Check the screws holding the blade holders to the fan motor. Tighten as necessary.
Check the angle of the blades to make sure that a blade holder has not been bent during installation.
FAN NOISY DURING Check and tighten light fixture retaining screws, glass shade screws and/or the light bulb(s).
OPERATION Tighten canopy screws and mounting plate assembly.
Tighten the blade to bladeholder screws and blade holders to flywheel. Make sure all screws in the motor housing are snug, but not overly tight.
Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have fallen off the wire splices. Tighten or adjust as necessary.
DOES NOT RUN ON If new,
LOW SPEED
LIGHTS FLASH OR BLINK DURING OPERATION OF
WHEN AC POWER IS TURNED ON FOR THE FIRST TIME,THE LIGHTS OPERATE NORMALLY, BUT
THE FAN: Reverse the 2 black and white striped wire connections.
FAN OR LIGHTS APPEAR TO OPERATE BY THEMSELVES (CHANGING SPEED OR INTENSITY),WALL CON- TROL OPERATION IS INTERMITTENT: Check AC supply for irregularities, (noise spikes, fluctuations, or failure); or circuit
board assembly.