Axis Communications T8123, T8126, T8128 manual Troubleshooting, Symptom Corrective steps

Page 8

Page 8

High PoE Midspan and Splitters Installation Guide

Troubleshooting

Symptom

Corrective steps

 

 

 

Midspan does not power up

1.

Verify that an approved power cable is used.

 

2.

Verify that the voltage at the power inlet is between 100 and

 

 

240V AC.

 

3.

Remove and re-apply power to the device and check the

 

 

indicators during power up sequence.

 

 

 

A port indicator is not lit and the PD

1.

The Midspan did not detect a PD; and the port is not enabled.

(powered device) does not operate

2.

Verify that the PD is designed for PoE operation.

 

3.

Verify that you are using a standard Category 5/5e/6, straight-

 

 

wired cable, with four pairs.

 

4.

If there is an external PoE device is connected, replace it to verify

 

 

that it is functioning properly.

 

5.

Ensure that the input Ethernet cable is connected to the Data In

 

 

port.

 

6.

Verify that the PD is connected to the Data & Power port.

 

7.

Try to reconnect the same PD into a different Midspan. If it works,

 

 

there is probably a faulty port or RJ-45 connection.

 

8.

Verify that there is no shortcut over any of the twisted pair cables

 

 

or over the RJ45 connectors.

 

 

 

The end device operates, but there is

1.

Verify that the port indicator on the front panel is continuously

no data link

 

lit.

 

2.

If an external PoE device is in use, replace it with a known good

 

 

PoE device.

 

3.

Verify that for this link, you are using standard UTP/FTP Category

 

 

5 straight (non-crossover) cabling, with all four pairs.

 

4.

Verify that the Ethernet cable length is less than 100 meters (333

 

 

feet) from the Ethernet source to the powered device.

 

5.

Try to reconnect the same PD into a different Midspan. If it works,

 

 

there is probably a faulty port or RJ-45 connection.

 

 

 

Image 8
Contents Installation Guide Safety information for Axis High PoE Midspan only Personnel onlyWeee Directive Electromagnetic Compatibility Standard AS/NZS CISPR22Page Preliminary steps Package contentsFunctions and features Color Indication InstallationData Specifications Mode Temperature HumidityPower provided over spare pairs 4/5+ and 7/8 For Gigabit EthernetTroubleshooting Symptom Corrective stepsMounting instructions 8 to 7.0 mm 0.23 to 0mm 5mm to 2.5 mm 0.059 toHigh PoE Splitter Power adapter cable Cable for Axis cameras with PS-K connectorAxis High PoE Splitter High PoE SplitterEthernet 10/100/1000Base-T, plus 48 VDC Input Data4/5 Page Étapes préliminaires Contenu de l´emballageFonctions et caractéristiques Indicateur Éteint Aucune caméra connectée Clignotement Installation de linjecteurTémoin Couleur Indication Mode Température Humidité Caractéristiques techniquesRésolution des problèmes Symptôme CorrectionInstructions de montage Alignez l´ Axis T8123 aux visses pour le fixerInstallation du sépateur PoE Séparateur 12V Axis T8126 High PoEFrançais Page Lieferumfang Funktionen und MerkmaleVorbereitende Schritte Axis High PoE Midspan Axis T8123 High PoE Midspan 1-portFarbe Bedeutung Port Leuchtet nicht Keine Kamera angeschlossen BlinktTechnische Daten Modus Temperatur LuftfeuchtigkeitSymptom Abhilfemaßnahmen FehlerbehebungMontageanweisungen Bis 7.0 mm 0.23 to 0mm 5mm bis 2.5 mm 0.059 aInstallieren des Gerätes Ethernet Anschluss Page Operazioni preliminari Contenuto della confezioneFunzioni e caratteristiche Colore Indicazione Installazione dellunitàIndicatore Spento Nessuna telecamera connessa Lampeggiante Dati tecnici Modalità Temperatura UmiditàTensione nominale in uscita 55V DC Gigabit Ethernet vengono usate tutte le coppieRisoluzione dei problemi Problema Azione correttivaIstruzioni per linstallazione 8 a 7.0 mm 0.23 to 0mm 5mm a 2.5 mm 0.059 aCavo per Axis 225FD Lunghezza di ogni cavo 1m / 3.33 piediCavo per Axis 231D+, Axis 232D+, Axis 233D Lunghezza 5m / 16.65 piediModalità Temperatura Umidità Di esercizio 40C 10 to 90% senza condensa 32 104FImmagazzinaggio 20 70C 158FPage Contenido del Paquete Funciones y característicasPasos preliminares JapónInstalación de la unidad Color IndicaciónConexiones eléctricas EspecificacionesModo Temperatura Humedad Solución de problemas Síntoma Pasos correctivosInstrucciones de montaje 8 to 7.0 mm 0.23 to 0mm 5mm to 2.5 mm 0.059 aCable adaptador de corriente Axis T8126 High PoE Splitter Cable para Axis 225FDLongitude de cada cable 1m / 3.33 feet Longitud 5m / 16.65 feetEn funcionamiento 40C 32 104F En almacenamiento 20 70C 158FPage パッケージの内容 Data & Power OUT ポート Data in ポート インストール製品仕様 トラブルシューティング 取り付け手順 Axis T8126 High PoE スプリッタ 12V および Axis T8128 High PoE スプリッタ 入力電圧 Page