American Standard 754323-100 Rev A, American Standard bath manual Install

Page 15

ELECTRICAL INSTALLATION INSTRUCTIONS (continued)

Ensure the heater and pump are properly GROUNDED and BONDED as required. Attach the 8 AWG solid copper conductor supplied with the heater from the heater bonding lug to the motor frame bonding lug as shown in Figure 3.

The conductor is secured to the lugs using set screws. The motor frame shall have a second 8 AWG solid copper conductor connected from the frame bonding lug to the home’s electrical panel or approved local bonding point as shown in Figure 3.

(HEATER)

 

 

HEATER ON

E-Z INSTALL

WHIRLPOOL

HEATER

(PUMP/MOTOR)

RUN 8 AWG SOLID COPPER

CONDUCTORS FROM

HEATER BONDING LUG TO

PUMP/MOTOR FRAME LUG

AND FROM PUMP/MOTOR

LUG TO APPROVED

GROUND AS SHOWN

FIRST COPPER

CONDUCTOR

SECOND

COPPER

CONDUCTOR

PUMP/MOTOR FRAME WITH BONDING LUGS

TO GROUND

FIGURE 3: GROUNDING DIAGRAM

WHIRLPOOL HEATER OPERATION

WARNING: Prior to operation, review the Important Safety

Instructions listed at the beginning of this instruction manual.

Once the heater is installed and the whirlpool pump is operating, the heater is totally automatic. The heater will help maintain the temperature of the water in the bath.

Pressure Switch

The heater is equipped with a preset pressure switch. The pump must be running with water flowing in the whirlpool to allow the heater to turn on.

Indicator Light

This light turns on whenever the heater is operating.

WHIRLPOOL

HEATER

E-Z INSTALL

HEATER “ON” LIGHT

FACTORY INSTALLED - NOT FOR RESALE

HEATER P/N: 753174-100

Bonding Lug on

 

Heater Housing

FIGURE 4: WHIRLPOOL HEATER INDICATOR LIGHT

High-Limit Switch

The heater includes an exclusive "Intelligent High-Limit". This safety circuit will not "false trip" from hot tap water. It will only turn the heater off if the thermostat fails. If the high-limit trips frequently, call a service technician.

To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply

(1)Turn off the whirlpool pump.

(2)Drain water from the tub.

(3)Remove power from heater by unplugging at receptacle or turning off circuit breaker.

(4)The heater circuit will automatically reset in less than 15 minutes.

(5)Restore power to the heater.

(6)Whirlpool bath is now ready to use.

15

754323-100 Rev A

Image 15
Contents Installation Guide for Green TEA Table of Contents Important Safety Instructions Leveling Stringer not Cutout in Floor for Drain Whirlpool Control AIR Jets Panels Cutout in Floor For Drain Leveling Stringer not To Overflow Access AIR BlowerPump Motor Whirlpool Heater Lighting System AT this END of TUBSkid Resistant Integral Fitting DeckFloor Cutout OutlineAIR ControlPanels Floor Cutout Whirlpool JetsROUGHING-IN References General Specifications for Combination System Installation and Framing Instructions Electrical Installation Diagram Install Under Deck Mounting Instructions Before installing bath into Framed out structure$0//&$5*0   BTTIPXOJOQIPUPT#BOE$  EJTUVSCTJMJDPOFCFBE $0//&$5*0/DPOUJOVFE 0WFSGMPXOVU SJOHJSCBUI Gjuujoh   EJTITPBQBTTIPXOJOQIPUP4  IPMEXBUFSEVSJOHVTF4FFQIPUP9  PWFSGMPXFTDVUDIFPOJOQMBDFQFSQIPUPT5BOE61045*/45--5*0/$-&/61 $3&BOE$34$&.*$-4406-%/&7&3#&64&%0/$3-*$463$&4 JOTUBMMBUJPONBLFTUIJTFGGPSUQSBDUJDBM 05&#-08&3-0$5*0/015*0/United States