ROUGHING-IN REFERENCES
GREEN TEA™ 6' x 36"
MODEL 3573 COMBINATION SYSTEM
TOP VIEW
72
(1829mm)
(375mm)
OUTLINE OF CUTOUT 70.5 x 34.5 (1780 x 876mm) |
| |
|
(292mm)
ACCESS AIR BLOWER, PUMP MOTOR,
WHIRLPOOL HEATER AND LIGHTING SYSTEM
AT THIS END OF TUB
9
(229mm)
CUTOUT IN FLOOR
FOR DRAIN
36
(914mm)
C
L
| 10 WHIRLPOOL | CONTROL | 23 AIR JETS | |||
| PANELS | |||||
|
| JETS |
| |||
|
|
|
| |||
|
|
|
| C | LEVELING STRINGER NOT | |
51mm |
|
|
| L TO OVERFLOW | ||
|
|
| 102mm (4") | FOR SUPPORT | ||
(2") |
|
|
|
|
|
|
END VIEW
559mm | INTEGRAL FEET |
(22") | WITH ATTACHED |
508mm | BASEBOARD |
(20") | ROUGH |
| FLOOR |
NOTE:
INSTALLER MUST PROVIDE 12 X 24 ACCESS OPENING FOR SERVICING AIR
BLOWER, PUMP MOTOR, WHIRLPOOL HEATER, AND LIGHTING SYSTEM.
THIS MODEL INCLUDES A DRAIN ASSEMBLY. OTHER DRAIN ASSEMBLIES
CANNOT BE USED. REVIEW DRAIN INSTALLATION DETAILS IN THE DOCUMENT
TO FULLY UNDERSTAND FLOOR CUTOUT REQUIREMENTS.
6 |