10Installation
This hob is designed to be connected to a 230 V 50 Hz AC electrical supply.
Before switching on, make sure the electricity supply voltage is the same as that indicated on the hob rating plate. The rating plate is located on the bottom of the hob.
The hob is supplied with a 3 core flexible supply cord incorporating a 3 amp plug fitted. In the event of having to change the fuse, a 3 amp ASTA approved (BS 1362) fuse must be used.
1 2
3
4
5
1Green and Yellow
23 amp fuse
3Brown
4Cord clamp
5Blue
Should the plug need to be replaced for any reason, the wires in the mains lead are col- oured in accordance with the following code:
Green and Yellow | - Earth |
Blue | - Neutral |
Brown | - Live |
1.Connect the green and yellow (earth) wire to the terminal in the plug which is marked with the letter 'E' or the earth symbol or coloured green and yellow.
2.Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter 'N' or coloured black.
3.Connect the brown (live) wire to the terminal in the plug which is marked with the let- ter 'L' or coloured red.
Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.
A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely.
The replacement of electric cable must be carried out exclusively by the service force centre or by personnel with similar competencies, in accordance with the current regulations.