Cal Spas LTR20121002 manual Important Safety Instructions, Hyperthermia Danger

Page 3

Important Safety Instructions

3

When installing and using this electrical equipment, always follow basic safety precautions. Following these instructions will help make your first spa ses- sion a pleasurable one.

READ AND FOLLOW ALL INSTRUCTIONS

NOTE: A licensed electrician may be required to up- grade your standard receptacle and/or circuit break- er.

DANGER -- RISK OF ACCIDENTAL DROWN- ING: Do not allow children to be in or around a spa unless a responsible adult supervises them. Keep the spa cover on and locked when not in use. See instructions enclosed with your cover for locking pro- cedures.

DANGER -- RISK OF INJURY: The suction fittings in this spa are sized to match the specific water flow created by the pump. Should the need arise to re- place the suction fittings, or the pump, be sure the flow rates are compatible.

DANGER -- RISK OF INJURY: Never operate the spa if the suction fitting or filter baskets are broken or missing.

DANGER -- RISK OF INJURY: Never replace a suction fitting with one that is rated less than the flow rate marked on the original suction fitting.

DANGER -- RISK OF ELECTRIC SHOCK: Install the spa at least five feet (1.5 meters) from all metal surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently bonded by a minimum #8 AWG solid copper conductor to the outside of the spa’s control box.

DANGER -- RISK OF ELECTRIC SHOCK: Do not permit any external electrical appliances, such as lights, telephones, radios, televisions, and etc., within five feet (1.5 meters) of the spa. Never at- tempt to operate any electrical device from inside the spa. This does not apply to lights built in to the spa as factory options from Cal Spas™.

WARNING -- RISK OF INJURY

The spa water should never exceed 104˚F (40˚C). Water temperatures between 100˚F (38˚C) and

104˚F (40˚C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes.

High water temperatures have a high potential for causing fetal damage during pregnancy. Women who are pregnant, or who think they are pregnant, should always check with their physician prior to spa usage.

The use of alcohol, drugs or medication before or during spa use may lead to unconsciousness, with the possibility of drowning.

Persons suffering from obesity, a medical history of heart disease, low or high blood pressure, circula- tory system problems or diabetes should consult a physician before using the spa.

Persons using medications should consult a physi- cian before using the spa since some medications may induce drowsiness while others may affect heart rate, blood pressure and circulation.

Hyperthermia Danger

Prolonged exposure to hot air or water can induce hyperthermia. Hyperthermia occurs when the inter- nal temperature of the body reaches a level 3˚F to 6˚F above the normal body temperature of 98.6˚F (or 2˚C to 4˚C above 37˚C). While hyperthermia has many health benefits, it is important not to allow your body’s core temperature to rise above 103˚F (39.5˚C). Symptoms of excessive hyperthermia in- clude dizziness, lethargy, drowsiness and fainting. The effects of excessive hyperthermia may include:

Failure to perceive heat

Failure to recognize the need to exit spa or hot tub

Unawareness of impending hazard

Fetal damage in pregnant women

Physical inability to exit the spa

Unconsciousness

WARNING: The use of alcohol, drugs, or medi- cation can greatly increase the risk of fatal hyper- thermia.

Read This First!

Inground Spas

LTR20121002, Rev. A

www.calspas.com

Image 3
Contents LTR20121002, Rev. a 12/30/11 Clear Water Plan Cleaning and MaintenanceDiverter Knobs Inground Spa Installation Checklist Preparing for Your New Inground SpaHyperthermia Danger Important Safety InstructionsInground Spa Installation Checklist Preparing for Your New Inground SpaPlanning the Best Location For Your Spa Site Excavation Hard Bottom Planning the Best Place for the Outdoor Equipment PackInground Spa Site Preparation Grading Prior to ExcavationIG-401 Spa Shell Dimensions and Side ViewsIG-402 IG-403 IG-404 IG-405 IG-406 IG-407 Electrical Requirements US and Canada Gfci and Wiring RequirementsTesting the Gfci Breaker Spa Model Gfci Required Wires RequiredGfci Wiring Diagram Electrical Installation -- Europe RCD and Wiring RequirementsTesting the RCD Breaker ForPreparing RCD Wiring DiagramInstalling the Inground Shell Plumbing Connections Equipment Pack Plumbing ConnectionsGate/Slice Valves Connecting Plumbing to Remote EquipmentRemote Equipment Topside Control Panel Electrical and Electronic ConnectionSee figure below Inground Spa Light Installation In- structionsPreparing forYour New Inground Spa Pouring the Deck Electronic Control Operation Light Setting the Temperature LockPreset Filter Cycles Clean-up CycleRCL Periodic Reminder MessagesMessage Frequency Action Required RPH RSADry Diagnostic MessagesMessage Meaning Action Required No message On displayMessage Meaning Action Required Snb SnsStby Diverter Knobs Adjustable JetsContents of this section Clear Water PlanKey to Clear Water Recommended total alkalinity is 80 120 ppm Testing and Adjusting Spa WaterBalancing the Total Alkalinity Balancing the pHUsing Chlorine as a Sanitizer Using Bromine as a SanitizerSanitation Filter Cleaning Chemical SafetyShocking the Water Starting the Spa with Fresh Water Bather LoadMaintenance Schedule Cleaning and Maintenance Removing and Reseating the PillowsSpa Cover Cleaning and Replacing the Filter Draining Your SpaWinterizing Cold Climate Draining Cleaning Your Spa Spa Cover and PillowsSpa Shell Replacement Parts WarrantyAppendix LTR20121002, Rev. a 12/30/11