Exmark LAZER AS manual Transporting a Unit

Page 17

Operation

tube to provide minimum obstruction to flow. Make sure that the upper and the lower ends are oriented properly as the tubes are assembled. (Parting lines should roughly be lined up.)

Figure 18

1.Drill the holes here

28.Slide the lower end of the tube assembly over the blower outlet and align the notch with the tube latch. Latch the tube to the blower.

29.Install the removable weights. Hook the front toe board weight assembly over the top of the weight mounting plate and secure with two hairpins Figure 19).

Weight Quantities

Deck

48 inch

52 inch

60 inch

72 inch

Size

 

 

 

 

 

 

 

 

 

Toe

3

2

2

1

Board

 

 

 

 

Weight

 

 

 

 

Caster

2

2

Weight

 

 

 

 

Note: The removable weights are heavy. Use care when lifting them. make sure that you can hold them securely before lifting them. Use caution when positioning your hands to that you Do Not set them down on your hands or fingers.

Figure 19

30.For LZUV3B Units Only:

A.Install the removable caster weights on the caster arms (see Figure 20).

B.Insert the clevis pin through the bracket hole and fasten with a hairpin.

C.Tighten knob on weight assembly until the weight is clamped securely to the caster arm.

 

 

Figure 20

 

 

 

For LZUV3B Units Only

1.

Clevis pin

3.

Hairpin

2.

Knob

4.

Caster weight

 

 

 

 

Transporting

Transporting a Unit

Use a heavy-duty trailer or truck to transport the machine. Lock brake and block wheels. Securely fasten the machine to the trailer or truck with straps, chains, cable, or ropes. Be sure that the trailer or truck

17

Image 17
Contents Ultra VAC All Rights Reserved Introduction Contents Safe Operating Practices SafetySafety Alert Symbol Slope Operation Maintenance and Storage Safety and Instructional Decals 103-3508 Dimensions SpecificationsModel Numbers SystemsOperation Product OverviewPre-Start Operating InstructionsCollection System Removal for Side Discharge Blower latch Pivot blower away from deck Collection System Installation Small Decks View from Top of Blower Set the deck in lowest cutting position Transporting a Unit TransportingRollover Protection System Rops Loading a UnitOperation Check Bags MaintenanceCheck Blower Housing/Impeller Check Exhaust Diverter Adjusting the Blower Drive Belt PositionLubricate Grease Fittings Check Condition of BeltClean Blower Clean Muffler and Rear Frame AreaClean Rear Screen In Hopper Problem Possible Cause Corrective Action TroubleshootingExmark Commercial Attachments and Accessories Page Service Record Page See EXMARK’S Complete Line of Accessories and Options