GE GEH-5304A manual Inspection Before Starting, Bearings and Couplings, Commutator and Brushes

Page 12

GEH-5304A

Before starting the motor, remove all unused shaft keys and loose rotating parts to prevent them from flying off.

A.Inspection Before Starting

These inspection procedures should be followed before starting the machine for the first time, after an ex- tended shutdown or after a teardown for extensive maintenance or repair.

1.Bearings and Couplings

Machines with ball or roller bearings are greased at the factory and will need no attention until relu- brication is necessary as suggested in the Maintenance section of this instruction book.

If the flexible couplings are a lubricated type, they should be checked to see that they contain the proper amount of lubricant.

Make sure that all grease plugs are tight.

2.Commutator and Brushes

Brushes should be worn in to have at least 85% contact over the brush surface and continuous contact from heel to toe. The commutator surface and undercut mica should be clean and free from dirt, grease, paint spots or brush dust.

Brushes should be free to move in the holders and all springs should be down and latched. Brush pigtail connections should be tight and the pigtails should not interfere with the action of the spring or brush and should be clear of any other part of the machine.

B.Rectified Power Supplies

When DC motors are operated from rectified power supplies, the pulsating voltage and current wave forms affect the motor performance by increasing motor heating and degrading commutation. Because of these ef- fects, it is necessary that the motors be designed or specially selected to suit this type of operation.

The ratings of DC motors intended for operation from rectified power supplies are based upon motor tests using a suitable power supply. The specific characteristics for three-phase rectified power supplies described in the Power Supply Identification section are in common use. For operation of motors from rectified power supplies other than those given in this section, refer to GE Industrial Systems.

A motor may, under some conditions, be operated from a power supply different from that indicated on the nameplate. Letters used to identify power supplies in common use have been chosen in alphabetical order of increasing magnitude of ripple current. Power supply compatibility can be judged by Table 4.

12

Image 12
Contents Instructions Copyright 1985, 1992, 1999 General Electric Company Table of Contents Storage of Renewal Parts II. Receiving StorageHandling Typical Weights LocationMounting AlignmentCoupled Drive Grouting Belt DrivesBearing Life Belt Tension Factor, Kb Special Load Considerations Pinion DrivesThrust Loads Maximum Continuous Thrust Capacity, LbsRectified Power Supplies Inspection Before StartingBearings and Couplings Commutator and BrushesSpeed Life Factor Less Than 500 Bearing Life at 1750 RPM Average Speed Vs. Load, WFrame Sizes CD2812AT and CD2813AT Power Supply Available Connections Protective DevicesMotor Field Heating ThermostatsAccessories & Special Device Markings Lead Markers FunctionWinding A1, A2 F1, F2, F3, F4, etc. T1, T2, T3, T4, etcVentilation System General Mechanical InspectionAccessory Mounting Bolt Tightening Torque ValuesBrakes Inspection After StartingInspection After Short Time in Service Noise and VibrationDisassembly ReassemblyReplacement of Bearings Recommended Regreasing PeriodsFrame Size CD2512AT- CD2813AT Average Standard Bearings for CD2512AT-CD2813AT MotorsStandard Temperature 15F to 212F -10C to 100C Low TemperatureHigh Temperature-20F to 350F -28C to 176C Sources of Supply for Bearing GreasesBrush Installation Brush Assembly CommutatorCommutator Diameters In Inches Mechanical Shaft End PlayWaterproof Machines Lubrication of Flexible CouplingsGEH-5304A Ues Testing Methods Visual Inspection Insulation Resistance MeasurementEffect of Temperature on Insulation Resistance Cleaning of WindingsOily Dirt Service Shop Cleaning Drying of WindingsRepair VI. Renewal Parts Storage of Renewal PartsNumber of Duplicate Motors in Service Description Recommended Spare PartsWith or Without Electrical Shop Facilities With Electrical Shop FacilitiesCommutator Check Chart Application Information for CD2512AT CD2813AT Frames GEH-5304A Dimensions, Air Openings for CD2512AT CD2813AT Frames Air Flow Requirements For Separately Ventilated Motors Frame 2512AT, 2513AT 2812AT, 2813AT Base SpeedAll Renewal Parts For CD2512AT CD2813AT FramesAccessory Mounting CD2512AT CD2813AT Accessory Mounting CD2512AT CD2813AT GEH-5304A Type CD Frames 2512AT 2813AT 5HDGHU&RPPHQWV Detach and fax or mail to the address noted above Fort Wayne in 46801-2205 USA Isaac #

GEH-5304A specifications

The GE GEH-5304A is a sophisticated electronic device that has garnered attention for its applications in various industrial sectors. This cutting-edge equipment is primarily used for monitoring and controlling processes through advanced technology integration, making it a valuable asset for businesses looking to enhance operational efficiency.

One of the standout features of the GE GEH-5304A is its robust data acquisition system. This system effectively collects, processes, and analyzes data from multiple sensors and instruments, enabling real-time monitoring of critical parameters. With its high sampling rate and accuracy, the GEH-5304A ensures that users can make informed decisions based on reliable data, thus minimizing risks and enhancing productivity.

The GEH-5304A integrates seamlessly with various communication protocols, including Ethernet, RS-232, and RS-485. This versatility allows it to connect effortlessly to existing infrastructure and facilitates data sharing across different platforms. This interoperability is essential in modern industrial environments, where different systems must communicate for optimal performance.

Another key characteristic of the GEH-5304A is its user-friendly interface. The device features an intuitive display that provides clear visualizations of data trends, alarms, and system statuses. This ease of use empowers operators to quickly identify issues and make necessary adjustments, thereby reducing downtime and improving overall operational reliability.

In terms of advanced technology, the GEH-5304A boasts built-in diagnostics and predictive maintenance capabilities. These features enable it to identify potential problems before they escalate into failures, allowing for proactive maintenance and minimizing costly unscheduled outages. Moreover, the device's ability to log historical data plays a crucial role in trend analysis and long-term planning.

Durability is another hallmark of the GE GEH-5304A. Designed to withstand harsh industrial conditions, it demonstrates resilience against temperature fluctuations, vibration, and dust. This robustness enhances its longevity and reduces the frequency of replacements and repairs.

In summary, the GE GEH-5304A stands out in the market due to its advanced data acquisition capabilities, compatibility with multiple communication protocols, user-friendly interface, predictive maintenance functionalities, and rugged design. These features make it an essential tool for industries seeking to optimize performance, enhance monitoring, and ensure process reliability. With the ongoing evolution of technology, devices like the GEH-5304A are pivotal in driving operational success across various sectors.