GE GEH-5304A Mechanical, Shaft End Play, Waterproof Machines, Lubrication of Flexible Couplings

Page 25

GEH-5304A

G.Mechanical

Check the condition of air filters and replace filters if they are dirty. Check for unusual noises which were not present when the unit was originally installed. Check all electrical connections for tightness. Clean out any dirt from screens, louvers, etc. which would interfere with the flow of cooling air.

H.Shaft End Play

The CD2512AT-CD2813AT designs use a wavy washer (preload spring) to eliminate endplay.

I.Waterproof Machines

Waterproof machines require the use of sealing devices to exclude water from the bearings and from entering openings in the magnet frame. When a waterproof machine has been disassembled, it will be necessary to remove the old sealing compound from around the mating surfaces of the bearing brackets and magnet frame, from underneath the field pole bolt heads and bearing cap to bearing bracket bolt heads, and from around the conduit box adapter threads to the magnet frame. Reapply new sealant (use Titeseal T20-66, light weight, GE Part No. 905A999AC009) to these areas and wipe excess sealant with a clean rag slightly dampened with mineral spirits. Do not use silicone sealants. When accessories such as brakes and ta- chometers are disassembled, it will be necessary to reseal at the accessory mounting face. Prior to reassem- bly, inspect for damage at the gaskets around enclosure covers and at the shaft rubbing seals located in the bearing caps.

J.Lubrication of Flexible Couplings

Flexible couplings are normally lubricated with a semi-fluid grease or an oil. The coupling manufacturers’ instructions should be followed in choosing a lubricant and setting relubrication intervals. GE ball bearing grease D6A2C5 is a suitable lubricant for flexible couplings in most applications.

Flexible couplings which join a small machine to a large machine may have two different size coupling halves joined by an adapter plate. Couplings of this type have a separate lubricant supply for each half. Therefore, both halves must be lubricated separately.

K.Insulation

Eliminate sources of contamination and moisture for maximum insulation life. Air filters for blowers, air piped from cleaner locations, shielding from water leads or spray, proper use of space heaters during downtime, etc., will all help to prolong insulation life.

Contamination includes excessive moisture, oily vapors, conducting and non-conducting dust, chips and chemical fumes. Contamination is best avoided by proper enclosure and ventilation. Filters, ventilation from a remote clean air source, unit coolers and a totally enclosed construction are all possible means of protecting DC machines in adverse environments. Space heaters protect against moisture damage by main- taining the machine above dew-point during storage or when idle. Space heaters should be arranged so that they are automatically energized whenever power is removed from the motor. Space heaters do not supply enough heat for drying out windings which have been water-soaked.

Mechanical factors include shock, vibration, overspeed, etc. Maintaining machines in good mechanical re- pair, including isolation from excessive external shock and maintenance of smooth running conditions, will contribute to long insulation life.

The insulation system in these machines is capable of withstanding some short time periods of operation at temperatures higher than than used for the basis of machine rating. Prolonged or excessively high tempera- ture will cause the insulation to become brittle and crack, leading to premature failure. Application data is available from GE Industrial Systems for any particular machine giving suggested maximum loads for vari- ous operating conditions. Operation within these maximum loads will limit the temperature to suitable val-

25

Image 25
Contents Instructions Copyright 1985, 1992, 1999 General Electric Company Table of Contents Storage of Renewal Parts Storage II. ReceivingHandling Location Typical WeightsAlignment MountingCoupled Drive Belt Drives GroutingBearing Life Belt Tension Factor, Kb Pinion Drives Special Load ConsiderationsThrust Loads Maximum Continuous Thrust Capacity, LbsInspection Before Starting Rectified Power SuppliesBearings and Couplings Commutator and BrushesBearing Life at 1750 RPM Average Speed Vs. Load, W Speed Life Factor Less Than 500Frame Sizes CD2812AT and CD2813AT Power Supply Available Protective Devices ConnectionsMotor Field Heating ThermostatsLead Markers Function Accessories & Special Device MarkingsWinding A1, A2 F1, F2, F3, F4, etc. T1, T2, T3, T4, etcGeneral Mechanical Inspection Ventilation SystemBolt Tightening Torque Values Accessory MountingBrakes Inspection After StartingNoise and Vibration Inspection After Short Time in ServiceReassembly DisassemblyRecommended Regreasing Periods Replacement of BearingsFrame Size CD2512AT- CD2813AT Average Standard Bearings for CD2512AT-CD2813AT MotorsLow Temperature Standard Temperature 15F to 212F -10C to 100CHigh Temperature-20F to 350F -28C to 176C Sources of Supply for Bearing GreasesBrush Installation Commutator Brush AssemblyCommutator Diameters In Inches Shaft End Play MechanicalWaterproof Machines Lubrication of Flexible CouplingsGEH-5304A Ues Insulation Resistance Measurement Testing Methods Visual InspectionCleaning of Windings Effect of Temperature on Insulation ResistanceOily Dirt Drying of Windings Service Shop CleaningRepair Storage of Renewal Parts VI. Renewal PartsRecommended Spare Parts Number of Duplicate Motors in Service DescriptionWith or Without Electrical Shop Facilities With Electrical Shop FacilitiesCommutator Check Chart Application Information for CD2512AT CD2813AT Frames GEH-5304A Dimensions, Air Openings for CD2512AT CD2813AT Frames Frame 2512AT, 2513AT 2812AT, 2813AT Base Speed Air Flow Requirements For Separately Ventilated MotorsAll Renewal Parts For CD2512AT CD2813AT FramesAccessory Mounting CD2512AT CD2813AT Accessory Mounting CD2512AT CD2813AT GEH-5304A Type CD Frames 2512AT 2813AT 5HDGHU&RPPHQWV Detach and fax or mail to the address noted above Fort Wayne in 46801-2205 USA Isaac #

GEH-5304A specifications

The GE GEH-5304A is a sophisticated electronic device that has garnered attention for its applications in various industrial sectors. This cutting-edge equipment is primarily used for monitoring and controlling processes through advanced technology integration, making it a valuable asset for businesses looking to enhance operational efficiency.

One of the standout features of the GE GEH-5304A is its robust data acquisition system. This system effectively collects, processes, and analyzes data from multiple sensors and instruments, enabling real-time monitoring of critical parameters. With its high sampling rate and accuracy, the GEH-5304A ensures that users can make informed decisions based on reliable data, thus minimizing risks and enhancing productivity.

The GEH-5304A integrates seamlessly with various communication protocols, including Ethernet, RS-232, and RS-485. This versatility allows it to connect effortlessly to existing infrastructure and facilitates data sharing across different platforms. This interoperability is essential in modern industrial environments, where different systems must communicate for optimal performance.

Another key characteristic of the GEH-5304A is its user-friendly interface. The device features an intuitive display that provides clear visualizations of data trends, alarms, and system statuses. This ease of use empowers operators to quickly identify issues and make necessary adjustments, thereby reducing downtime and improving overall operational reliability.

In terms of advanced technology, the GEH-5304A boasts built-in diagnostics and predictive maintenance capabilities. These features enable it to identify potential problems before they escalate into failures, allowing for proactive maintenance and minimizing costly unscheduled outages. Moreover, the device's ability to log historical data plays a crucial role in trend analysis and long-term planning.

Durability is another hallmark of the GE GEH-5304A. Designed to withstand harsh industrial conditions, it demonstrates resilience against temperature fluctuations, vibration, and dust. This robustness enhances its longevity and reduces the frequency of replacements and repairs.

In summary, the GE GEH-5304A stands out in the market due to its advanced data acquisition capabilities, compatibility with multiple communication protocols, user-friendly interface, predictive maintenance functionalities, and rugged design. These features make it an essential tool for industries seeking to optimize performance, enhance monitoring, and ensure process reliability. With the ongoing evolution of technology, devices like the GEH-5304A are pivotal in driving operational success across various sectors.