GE GEH-5304A manual Mounting, Alignment, Coupled Drive

Page 8

GEH-5304A

B.Mounting

Motors and generators should be mounted on rigid and solid foundations. Level the base (or the machine). Hold-down bolts should be inspected regularly and kept tight. The feet of the machine may be doweled to the foundation plates or base when alignment procedures are completed. Sliding bases, when used, should be securely anchored to the foundation.

Motors are mechanically suitable for mounting with shaft horizontal or vertical on floor, ceiling or sidewall. When sidewall or ceiling mounted, special provisions must be made to maintain the integrity of dripproof enclosures.

When motor is sidewall or ceiling mounted, lifting points in addition to the standard lifting lugs may be required. Lifting, in these cases should be done by experienced riggers to avoid injury to personnel and damage to the motor.

C.Alignment

Be sure to align or check alignment carefully on either motors or motor genera- tor sets. Misalignment can cause excessive vibration and damaging forces on shafts and bearings.

Time taken to assure good alignment will be returned in reduced downtime.

1.Coupled Drive

When a motor is used to drive a unit, flexible couplings must be used to facilitate alignment. Three- bearing construction requires a rigid coupling.

D￿

Careful alignment of machines when using either solid (rigid) or flexible cou- )OH[LEOH$plingsLJQPHQW￿is&RXSOLQJ￿essential3URFHGXUH￿￿1RQto￿6HOIprevent￿6XSSRUWLQJexcessive￿%DVHVvibration and bearing or shaft failures.

Before grouting the base, the coupling should be checked as follows:

1.Slide the sleeve from the coupling so that the hub faces are exposed.

2.Check that the coupling hub spacing is in accordance with the outline dimensions with the units in the mechanical center of their end play.

3.Check parallel alignment by using a straightedge across the hubs at both vertical and horizontal locations, or by clamping a dial indicator to one hub and indicating the other hub on its outside diameter. Be sure that the dial indicator supports do not bend or sag, since this will give inaccurate readings.

4.Use a dial indicator at hub faces and rotate both units together 90°, 180°, 270° and 360° or measure the gap at each position by inserting a feeler gage. The reading should not vary more than 0.002”.

5. Correct any vertical misalignment by shimming between the base and the foundation.

8

Image 8
Contents Instructions Copyright 1985, 1992, 1999 General Electric Company Table of Contents Storage of Renewal Parts II. Receiving StorageHandling Typical Weights LocationCoupled Drive MountingAlignment Bearing Life GroutingBelt Drives Belt Tension Factor, Kb Special Load Considerations Pinion DrivesThrust Loads Maximum Continuous Thrust Capacity, LbsRectified Power Supplies Inspection Before StartingBearings and Couplings Commutator and BrushesFrame Sizes CD2812AT and CD2813AT Speed Life Factor Less Than 500Bearing Life at 1750 RPM Average Speed Vs. Load, W Power Supply Available Connections Protective DevicesMotor Field Heating ThermostatsAccessories & Special Device Markings Lead Markers FunctionWinding A1, A2 F1, F2, F3, F4, etc. T1, T2, T3, T4, etcVentilation System General Mechanical InspectionAccessory Mounting Bolt Tightening Torque ValuesBrakes Inspection After StartingInspection After Short Time in Service Noise and VibrationDisassembly ReassemblyReplacement of Bearings Recommended Regreasing PeriodsFrame Size CD2512AT- CD2813AT Average Standard Bearings for CD2512AT-CD2813AT MotorsStandard Temperature 15F to 212F -10C to 100C Low TemperatureHigh Temperature-20F to 350F -28C to 176C Sources of Supply for Bearing GreasesBrush Installation Commutator Diameters In Inches Brush AssemblyCommutator Mechanical Shaft End PlayWaterproof Machines Lubrication of Flexible CouplingsGEH-5304A Ues Testing Methods Visual Inspection Insulation Resistance MeasurementEffect of Temperature on Insulation Resistance Cleaning of WindingsOily Dirt Repair Service Shop CleaningDrying of Windings VI. Renewal Parts Storage of Renewal PartsNumber of Duplicate Motors in Service Description Recommended Spare PartsWith or Without Electrical Shop Facilities With Electrical Shop FacilitiesCommutator Check Chart Application Information for CD2512AT CD2813AT Frames GEH-5304A Dimensions, Air Openings for CD2512AT CD2813AT Frames Air Flow Requirements For Separately Ventilated Motors Frame 2512AT, 2513AT 2812AT, 2813AT Base SpeedAll Renewal Parts For CD2512AT CD2813AT FramesAccessory Mounting CD2512AT CD2813AT Accessory Mounting CD2512AT CD2813AT GEH-5304A Type CD Frames 2512AT 2813AT 5HDGHU&RPPHQWV Detach and fax or mail to the address noted above Fort Wayne in 46801-2205 USA Isaac #

GEH-5304A specifications

The GE GEH-5304A is a sophisticated electronic device that has garnered attention for its applications in various industrial sectors. This cutting-edge equipment is primarily used for monitoring and controlling processes through advanced technology integration, making it a valuable asset for businesses looking to enhance operational efficiency.

One of the standout features of the GE GEH-5304A is its robust data acquisition system. This system effectively collects, processes, and analyzes data from multiple sensors and instruments, enabling real-time monitoring of critical parameters. With its high sampling rate and accuracy, the GEH-5304A ensures that users can make informed decisions based on reliable data, thus minimizing risks and enhancing productivity.

The GEH-5304A integrates seamlessly with various communication protocols, including Ethernet, RS-232, and RS-485. This versatility allows it to connect effortlessly to existing infrastructure and facilitates data sharing across different platforms. This interoperability is essential in modern industrial environments, where different systems must communicate for optimal performance.

Another key characteristic of the GEH-5304A is its user-friendly interface. The device features an intuitive display that provides clear visualizations of data trends, alarms, and system statuses. This ease of use empowers operators to quickly identify issues and make necessary adjustments, thereby reducing downtime and improving overall operational reliability.

In terms of advanced technology, the GEH-5304A boasts built-in diagnostics and predictive maintenance capabilities. These features enable it to identify potential problems before they escalate into failures, allowing for proactive maintenance and minimizing costly unscheduled outages. Moreover, the device's ability to log historical data plays a crucial role in trend analysis and long-term planning.

Durability is another hallmark of the GE GEH-5304A. Designed to withstand harsh industrial conditions, it demonstrates resilience against temperature fluctuations, vibration, and dust. This robustness enhances its longevity and reduces the frequency of replacements and repairs.

In summary, the GE GEH-5304A stands out in the market due to its advanced data acquisition capabilities, compatibility with multiple communication protocols, user-friendly interface, predictive maintenance functionalities, and rugged design. These features make it an essential tool for industries seeking to optimize performance, enhance monitoring, and ensure process reliability. With the ongoing evolution of technology, devices like the GEH-5304A are pivotal in driving operational success across various sectors.