Husqvarna PAC IV-14KCR, PAC IV-8KM, PAC IV-9W Wiring Diagram 75E Models 7-1/2 HP, 3 Phase Electric

Page 26

FIGURE 8 - Wiring Diagram & Voltage Conversion-75E (7-1/2 HP, 3 Phase Electric)

This Figure applies to all 230V and 460V 7.5 HP electric Models. Conversion kits are available to convert to and from 230V and 460V 3 phase units.

Kit P/N 177442 Convert 230V to 460V

Kit P/N 177443 Convert 460V to 230V

NOTICE: The end user is responsible for providing electrical service in accordance with the National Electric Code and any other applicable local codes. Service must at the minimum, motor disconnection means, motor branch-circuit short-circuit protection, motor branch-circuit ground-fault protection, and correctly sized motor circuit conductors.

Connect the green and black wires to the electric motor as shown below for your specific unit. If the electric motor rotates backwards after wiring the unit, switch any two black line wires to reverse the motor direction.

ILUSTRACION 8 - Diagrama de Cableado y Conversión de Voltaje-75E (Eléctrico de 7-1/2 HP, 3 Fases)

Esta ilustración se aplica a todos los modelos eléctricos de 230V y 460V de 7.5 HP. Existen disponibles equipos de conversión para convertir unidades de 3 fases a /y de 230V y 460V.

Equipo P/N 177442 Convierte 230V a 460V

Equipo P/N 177443 Convierte 460V a 230V

NOTIFICACION: El usuario final es responsable de suministrar la energía eléctrica de acuerdo con el Código Nacional de Electricidad y cualquier otro código local aplicable. Como mínimo, el servicio de energía eléctrica debe tener medios para desconectar el motor, protección contra cortocircuitos del circuito ramal del motor, protección contra fallas de la conexión a tierra del circuito ramal del motor y conductores del circuito del motor correctamente dimensionados.

Conecte los cables verde y negro al motor eléctrico, tal como se muestra abajo para su unidad específica. Si el motor eléctrico rota al revés después de cablear la unidad, cambie dos líneas negras cualesquiera para revertir la dirección del motor.

WIRING DIAGRAM - 75E MODELS (7-1/2 HP, 3 Phase Electric)

26

Image 26
Contents PORT-A-CUT 542 20Parts List Index Indice DE LA Lista DE Piezas Safety First Advertencias Frame Group / Grupo de Marco Use Item 34C or 34D See Note C or D Diag Part Qty Loc Req Description * Denotes Metric ItemUse Item 33C or 33D See Note C or D Use Item 35C or 35D See Note C or DFrame Group / Grupo de Marco Shield, RH See Note E Diag Part Qty Loc Description * Denotes Metric ItemUse of Item 67C or 67D See Note C or D Use Item 95C or 95D See Note C or DPage 190092 Engine, 20H See Note J 16KM, 20H See Note JPage Parts List Items 13 Hinge Note HPage 167189 167959167963 Items Not Shown On Guard, Muffler Optional 14KM, 16KMDrivematic Group / Transmisión Automática Parts List Parts List See Notes Below Page Accessories / Accesorios Water Tank Kit 167965 Water Pump Kit 167966177059 Kit, Lift Bail All Models Except 20H Hour Meter Group 16BV & 18BVPage Qty Blade Spacers Not Included in this Kit Electrical Components for 75E Model Only 7-1/2 HP Electric Wiring Diagram 75E Models 7-1/2 HP, 3 Phase Electric Page Wiring Diagram 8KM 8 HP Kohler Magnum Wiring Diagram-10Y 10 HP Yanmar Diesel Wiring Diagram-13H 13 HP Honda Wiring Diagram-14KC 14 HP Kohler Command Electric Start Wiring Diagram-14KCR 14 HP Kohler Command Recoil Start Wiring Diagram-16KM 16 HP Kohler Magnum Electric Start Page Wiring Diagram 18 & 20 HP Honda Ref B-542190398 Wire Diagram 177920 139255 177016 166830 167869 177288 542190401 Page Page OFF Pieza Cant IdadSymbol Engine Model Page Water Tank Kit 5 Gal. Note Blade Guard Left / Right CuttingBrida Externa Corte de 1/2 Nota Equipo de Pesas 26 Libras NotaEquipo de Tanque de Agua Bomba de Agua Eléctrica NotaRepairs Page Dust Warning