Samsung SNOW-1703U Control Codes, Viewing control state (Get control command), Controlling (Set control command), Command, No, Command type, Command, Value range

LH015IFHSAS/EN, LH015IFHSAS/XV, LH015IFHTAS/EN, LH015IFHTAS/UE, LH015IFHTAS/XV, LH020IFHSAS/EN, LH025IFHSAS/EN, LH025IFHTAS/EN, LH040IFHTDS/EN, LH060IFHSDS/UE, SBB-SNOWH3U/EN, SBB-SNOWH3U/UE, SBB-SNOWH3U/XV

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 99
Download on canonical page 99 pages, 3.9 Mb

Control Codes

Viewing control state (Get control command)

Header

Command

ID

Data length

Checksum

 

 

 

 

 

0xAA

Command type

 

0

 

Controlling (Set control command)

Header

Command

ID

Data length

Data

Checksum

 

 

 

 

 

 

0xAA

Command type

 

1

Value

 

Command

No.

Command type

Command

Value range

 

 

 

 

1

Power control

0x11

0~1

 

 

 

 

2

Input source control

0x14

-

 

 

 

 

3

Screen mode control

0x18

-

 

 

 

 

4

Safety Lock

0x5D

0~1

•• All communications take place in hexadecimals. The checksum is calculated by adding up all values except the header. If a checksum adds up to be more than 2 digits as shown below (11+FF+01+01=112), the first digit is removed.

E.g. Power On & ID=0

Header

Command

ID

Data length

Data 1

Checksum

 

 

 

 

 

 

0xAA

0x11

 

1

"Power"

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

Command

ID

Data length

Data 1

12

 

 

 

 

 

 

0xAA

0x11

 

1

1

 

•• To control all devices connected by a serial cable simultaneously irrespective of IDs, set the ID as "0xFE" and transmit commands. Commands will be executed by each device but ACK will not respond.