Desa (V)JM42 manuals
Outdoor Cooking > Outdoor Fireplace
When we buy new device such as Desa (V)JM42 we often through away most of the documentation but the warranty.
Very often issues with Desa (V)JM42 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Outdoor Fireplace Desa (V)JM42 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Outdoor Fireplace on our side using links below.
Desa (V)JM42 Installation Manual
24 pages 1.97 Mb
2 TABLE OF CONTENTSSAFETY INFORMATION 3 SPECIFICATIONS MODELS VJM36 AND JM36www.desatech.com 117541-01A 4 4 SPECIFICATIONS MODELS VJM42 AND JM4241.250 23.500 24.250 117541-01A 5 5 SPECIFICATIONS6 FIREPLACE INSTALLATIONSELECTING LOCATION MINIMUM CLEARANCE TO COMBUSTIBLES WARNING: Do not pack re- quired air spaces with insulation or other materials. WARNING: Hearth extension is to be installed only as shown in Figure 3. 7 FIREPLACE INSTALLATIONMANTELSASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY SYSTEM 8 VENTING INSTALLATIONOPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F) CAUTION: Combustion air inlet ducts shall not terminate in attic space.Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inlet Eyebrow Vented Crawl Space (Check Local Codes Before Installing in a Vented Crawl Space) CHIMNEY PIPE 9 USING ELBOW OFFSETS (30E-12DM)2. Offset Elbow A B C Offset ElbowOffset ElbowReturn ElbowOffset Elbow Ceiling Support Pipe 12S-12DMReturn Elbow Figure 8 - Ceiling Support Pipe 12S-12DM 2" Min. See Detail B Straps Detail A Return Elbow Detail B Angle Firestop See Detail A 10 FIRESTOP SPACERS (FS-10, 1100EFS-10DM FOR JM36)11 FLASHING INSTALLATION (V6F-10DM OR V12F-10DM)Underlap Shingles at Bottom Overlap Shingles Top and Sides Only Figure 13 - Flashing Installation Figure 14 - Storm Collar Level of Flue Gas Outlet Stainless Inner Flue Pipe Waterproof Caulking Storm Collar Flashing Underlap Shingles Figure 15 - Termination 12 CHASE INSTALLATIONS10 FOOT RULE FINISHING THE FIREPLACE OPTIONAL GAS LINE 13 BRICK INSTALLATIONInstallation of brick should be done after the replace is placed in a permanent location.www.desatech.com 117541-01A 14 Figure 20 - Installing BrickBrick Stamped Letter Location Brick Housing Flanges 14 LEFT PANEL REAR PANELRIGHT PANELHEARTH PANELBRICK INSTALLATION FOR MODEL (V)JM36**See instruction above before installing brick "AR" INSTALLING BRICK "AO" OR "AR"Figure 21 - Installing Brick AO or AR 15 LEFT PANEL REAR PANELRIGHT PANELBRICK INSTALLATION FOR MODEL (V)JM42 HEARTH PANEL 19 Allow 72 hours before operating replace.See Chart for Grate Retainer Brackets Location Model Distance Apart JM50 8 3/4" Centers JM42 4 1/4" Centers JM36 3 1/4" Centers 20 GLASS DOOR IMPORTANT: Install glass door frame first before installing glass door.DOOR FRAME ASSEMBLY INSTALLING DOOR FRAME INSTALLING GLASS DOORS DOOR ADJUSTMENT 21 OPERATION AND MAINTENANCE GUIDELINESGLASS DOORS OUTSIDE AIR AND DAMPER HANDLE OPERATION OPERATION AND MAINTENANCE GUIDELINES 22 TECHNICAL SERVICE
Also you can find more Desa manuals or manuals for other Outdoor Cooking.