Desa (V)JM36 Venting Installation, Continued, FLASHING INSTALLATION V6F-10DM OR V12F-10DM

Models: (V)JM42

1 24
Download 24 pages 31.17 Kb
Page 11
Image 11
FLASHING INSTALLATION (V6F-10DM OR V12F-10DM)

VENTING INSTALLATION

Continued

4.Remove the shingles around the opening measured. Cut out this section.

5.Add the next sections of the pipe until the end penetrates the roof line. Check to see that the proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above the highest point of the roof cutout. Termination and chimney must extend a minimum of 36" above the highest point where it passes through the roof.

FLASHING INSTALLATION (V6F-10DM OR V12F-10DM)

Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles (see Figure 13). DO NOT NAIL THROUGH FLASHING CONE.

Installing Flashing on a Metal Roof

When installing the flashing on a metal roof, it is required that putty tape be used between the flash- ing and the roof. The flashing must be secured to the roof using #8 x 3/4" screws and then sealed with roof coating to prevent leakage through the screw holes. A roof coating must also be applied around the perimeter of the flashing to provide a proper seal.

Storm Collar Installation (SC2-1)

 

Place storm collar over pipe and slide down until

it is snug against the open edge of the flashing (see

Figure 14). Apply waterproof caulk around the

perimeter of the collar to provide a proper seal.

Chimney

Waterproof

Pipe

Caulk

Storm

Flashing

Collar

Figure 14 - Storm Collar

Terminations/Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations. In any case, refer to the installation instructions supplied with the termination.

Installing Flashing on a Metal Roof CAUTION: Do not seal open- ings on the rooftop flashing. Fol- low the installation instructions provided with the termination

being used.

 

 

RTL-10D

Stainless

Level of

Inner Flue

Flue Gas

Pipe

Storm Collar

Overlap

Outlet

Flashing

Cone

Nail Only

Outer

Perimeter

of Flashing

Shingles Top and Sides Only

Secure Termination to Outer Pipe with 3 Screws

Waterproof

Caulking

Storm

Collar

Flashing

Underlap

Shingles

at Bottom

Figure 13 - Flashing Installation

Underlap

Shingles

Figure 15 - Termination

117541-01A

www.desatech.com

11

Page 11
Image 11
Desa (V)JM36 Venting Installation, Continued, FLASHING INSTALLATION V6F-10DM OR V12F-10DM, Storm Collar, Termination