Guardian Technologies 004583-0 manuals
Lawn and Garden > Portable Generator
When we buy new device such as Guardian Technologies 004583-0 we often through away most of the documentation but the warranty.
Very often issues with Guardian Technologies 004583-0 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Portable Generator Guardian Technologies 004583-0 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Portable Generator on our side using links below.
Guardian Technologies 004583-0 Owner Manual
80 pages 4.89 Mb
Owners Manual1-800-333-1322 ULTRA SOURCE Portable GeneratorINTRODUCTION READ THIS MANUAL THOROUGHLY 3 GENERAL HAZARDS 4 WARNING!5 ELECTRICAL HAZARDS FIRE HAZARDS EXPLOSION HAZARDS STANDARDS IN DEX 6 1.1 UNPACKINGFigure 1 - Bracket Removal 1.1.1 ACCESSORY BOX 1.2 ASSEMBLY1.2.1 ASSEMBLING THE WHEEL KIT 1.2.2 ASSEMBLING THE HANDLE Shipping Bracket (x4) 8 2.1 KNOW THE GENERATORFigure 4 - Control Panel 15 12 14 89Figure 5 - Generator Controls Figure 6 - Engine Control Panel 7 11 9 2.2 CORD SETS AND CONNECTION PLUGS2.2.1 120 VAC, 20 AMP, DUPLEX RECEPTACLEFigure 9 - 120 VAC, 30 Amp Receptacle Figure 7 - 120 Volt AC, 20 Amp, Duplex Receptacle 2.2.2 120 VAC, 20 AMP, GFCI RECEPTACLEFigure 8 - 120 VAC, 20 Amp GFCI Receptacle 2.2.3 120 VAC, 30 AMP RECEPTACLE 2.2.4 120/240 VAC, 30 AMP RECEPTACLEFigure 10 - 120/240 VAC, 30 Amp Receptacle 2.2.5 12 VOLT DC, 10 AMP RECEPTACLEFigure 11 - 12 Volt DC, 10 Amp Receptacle 2.2.6 120/240 VAC, 50 AMP RECEPTACLEFigure 12 - 120/240 VAC, 50 Amp Receptacle 10 2.3 HOW TO USE THE GENERATOR2.3.1 G ROUNDING THE GENERATORFigure 13 - Grounding the Generator 2.3.2 CONNECTING ELECTRICAL LOADS 11 2.4 DONT OVERLOAD THE GENERATOR2.5 WATTAGE REFERENCE GUIDE 2.6 BEFORE STARTING THE GENERATOR2.6.1 ADDING ENGINE OIL 2.6.2 ADDING GASOLINE 12 Figure 14 - Fuel Tank 2.7 TO START THE ENGINE 13 Figure 16 - Idle Control Switch Figure 15 - Fuel Shut-off Valve Figure 17 - Full Choke Position 2.8 STOPPING THE ENGINE 2.9 AUTOMATIC IDLE CONTROL 2.10 COLD WEATHER OPERATION/DE-ICER 2.11 LOW OIL PRESSURE SHUTDOWN SYSTEM2.11.1 INITIAL START-UP 2.11.2 SENSING LOW OIL PRESSURE 2.11.3 RESTARTING 2.12 CHARGING A BATTERY 14 3.2.1 GENERATOR SPECIFICATIONS 3.2.2 ENGINE SPECIFICATIONS 15 3.1 MAINTENANCE SCHEDULE3.2 PRODUCT SPECIFICATIONSOperation Maintenance Daily Every Season Every Season Every Season 3.3 GENERAL RECOMMENDATIONS3.3.1 GENERATOR MAINTENANCE 16 3.3.2 TO CLEAN TH E GENERATOR 3.3.3 ENGINE MAINTENANCE 3.3.4 C HECKING OIL LEVEL 3.3.5 C HANGING THE OIL AND OIL FILTER 3.3.6 R EPLACING THE SPARK PLUGFigure 18 - Spark Plug Gap Figure 20 - Spark Arrestor 17 3.4 SERVICE AIR CLEANERFigure 19 - Air Cleaner Base Pre-Cleaner Filter Cover 3.5 CLEAN SPARK ARRESTOR SCREEN 3.6 ADJUSTING VALVE CLEARANCEFigure 21 - Valve Clearance Adjustment 3.7 GENERAL 18 19 20 4.1 TROUBLESHOOTING GUIDE5.1 KIT INCLUDESFigure 22 - Power Inlet Box Figure 23 - Power Inlet Box 5.2 TOOLS REQUIRED 5.3 ITEMS THAT MUST BE PURCHASED 5.4 TRANSFER SWITCH INSTALLATION 21 Figure 24 - Generator Location 22 Figure 25 - Drill Hole Through WallFigure 26 - Drill Hole Through Siding Figure 29 - Prepare Box for Connections Figure 27 - Feed Conduit Through Wall Figure 28 - Remove Lock Nut Figure 30 - Mount Box Figure 31 - Connect Wires 23 Figure 32 - Mount Manual Transfer Switch 44 Detail of Battery Tray Manual del Propietario 49 ULTRA SOURCE Generador PorttilINTRODUCCIN LEA DETENIDAMENTE ESTE MANUAL 51 RIESGOS GENERALES 52 ADVERTENCIA!53 RIESGOS ELCTRICOS RIESGOS DE INCENDIO RIESGOS DE EXPLOSIN NDICE DE NORMASINSTRUCCIONES IMPORTANTES DE SEGURIDAD 54 1.1 DESEMPAQUEFigura 1 - Remocin de las abrazaderas 1.1.1 CAJA DE ACCESORIOS 1.2 MONTAJE1.2.1 MONTAJE DEL JUEGO DE LA RUEDA 1.2.2 MONTAJE DE LA MANIJA Abrazadera de transporte (x4) 55 1.2.3 CONEXIN DE LA BATERAFigura 2 - Conjunto de la manija Figura 3 - Conexiones de la batera Cable negativo Cable positivo 56 2.1 FAMILIARCESE CON SU GENERADORFigura 4 - Panel de control 11Figura 5 - Controles del generador 7 15 12Figura 6 - Panel de control del motor 57 2.2 JUEGOS DE CORDONES ELCTRICOS Y ENCHUFES DE CONEXIN2.2.1 RECEPTCULO DPLEX DE 120 VCA, 20 Figura 7 - Receptculo dplex de 120 voltios de CA, 20 amperios 2.2.2 RECEPTCULO GFCI DE 120 VCA, 20 14 89Figura 8 - Receptculo GFCI de 120 VCA, 20 amperios 58 2.2.3 RECEPTCULOS DE 120 VCA, 30 Figura 9 - Receptculo de 120 VCA, 30 amperios 2.2.4 RECEPTCULOS DE 120/240 VCA, 30 Figura 10 - Receptculo de 120/240 VCA, 30 amperios 2.2.5 RECEPTCULO DE 12 VOLTIOS DE CC, 10 Figura 11 - Receptculo de 12 voltios de CC, 10 amperios 2.2.6 RECEPTCULO DE 120/240 VCA, 50 AMP Figura 12 - Receptculo de 120/240 VCA, 50 amperios 59 2.3 CMO USAR EL GENERADOR2.3.1 CONEXIN A TIERRA DEL GENERADORFigura 13 - Conexin a tierra del generador 2.3.2 CONEXIN DE LAS CARGAS ELCTRICAS 2.4 NO SOBRECARGUE EL GENERADOR 60 2.5 GUA DE REFERENCIA DEL VATAJE2.6 ANTES DE ARRANCAR EL GENERADOR2.6.1 ADICIN DE ACEITE DEL MOTOR 2.6.2 ADICIN DE GASOLINA 61 Figura 14 - Tanque de Combustible. Combustible del Tanque Combustible 1/2 2.7 ARRANQUE DEL MOTOR Figura 15 - Vlvula de Cierre del Combustible Figura 16 - Conmutador de control de marcha de vaco. Figura 17 - Posicin de Estrangulacin Completa. 62 2.8 DETENCIN DEL MOTOR2.9 CONTROL AUTOMATICO DE MARCHA DE VACIO 2.10 OPERACIN EN CLIMAS FROS/ DESHIELADOR 2.11 SISTEMA DE CIERRE POR BAJA PRESIN DE ACEITE2.11.1 ARRANQUE INICIAL 2.11.2 DETECCIN DE BAJA PRESIN DE ACEITE 2.11.3 REARRANQUE 2.12 CARGA DE L A BATERIA 63 3.2.1 ESPECIFICACIONES DEL GENERADOR 3.2.2 ESPECIFICACIONES DEL MOTOR 64 3.1 PROGRAMA DE MANTENIMIENTO3.2 ESPECIFICACIONES DEL PRODUCTOOperacin Mantenimiento Diariamente Cada temporada Cada temporada Cada temporada 3.3 RECOMENDACIONES GENERALES3.3.1 MANTENIMIENTO DEL GENERADOR 65 3.3.2 LIMPIEZA DEL GENERADOR 3.3.3 MANTENIMIENTO DEL MOTOR 3.3.4 MEDICIN DEL NIVEL DE ACEITE 3.3.5 CAMBIO DEL ACEITE Y DEL FILTRO DEL ACEITE 3.3.6 REEMPLAZO DE LA BUJAFigura 18 - Separacin Entre los Electrodos de la Buja Base Filtro 66 3.4 SERVICIO DEL PURIFICADOR DE AIREFigura 19 - Purificador de Aire CubiertaPrepurificador Para limpiar o reemplazar el prepurificador de espuma: 3.5 LIMPIEZA DE LA MALLA AMORTIGUADORA DE CHISPASFigura 20 - Malla amortiguadora de chispas 3.6 AJUSTE DE LA HOLGURA DE LA VLVULAFigura 21 - Ajuste de la holgura de la vlvula Entorno Brazo Mermeladas Nut Pivot Pelota Stud Vlvula Stem 3.7 GENERAL 67 3.8 ALMACENAMIENTO A LARGO PLAZO 68 3.9 OTRAS SUGERENCIAS PARA EL ALMACENAMIENTO 69 4.1 GUA DE LOCALIZACIN Y RESOLUCIN DE PROBLEMAS5.1 CONTENIDO DEL JUEGOFigura 22 - Caja de entrada de potencia Figura 23 - Caja de entrada de potencia 5.2 HERRAMIENTAS REQUERIDAS 5.3 ARTCULOS QUE ES NECESARIO COMPRAR 5.4 INSTALACIN DEL CONMUTADOR DE TRANSFERENCIA 71 72 Figura 24 - Ubicacin del generadorFigura 25 - Haga un orificio en la pared Figura 26 - Haga un orificio a travs del forrado Figura 27 - Pase el conducto a travs de la pared Figura 28 - Quite la contratuerca Figura 29 - Prepare la caja para las conexiones Figura 30 - Monte la caja Figura 31 - Conecte los cables 73 Figura 32 - Monte el conmutador de transferencia manual 74
Also you can find more Guardian Technologies manuals or manuals for other Lawn and Garden.