Samsung AR10NVFSCURNSV manuals
Household Appliance > Air Conditioner
When we buy new device such as Samsung AR10NVFSCURNSV we often through away most of the documentation but the warranty.
Very often issues with Samsung AR10NVFSCURNSV begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Air Conditioner Samsung AR10NVFSCURNSV is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Air Conditioner on our side using links below.
Samsung AR10NVFSCURNSV Manual
45 pages 0 b
1 AR**NVFH2 ContentsSafety Information At a Glance Power Smart Features Energy-SavingFeatures Cleaning and Maintenance Installation 3 Indoor Unit InstallationStep 2.1 Connecting the power and communication cables (assembly cable) Step 2.2 Optional: Extending the power cable Step 2.3 Installing and connecting the drain hose Step 2.4 Optional: Extending the drain hose Step 2.5 Optional: Changing the direction of the drain hose Step 2.7 Shortening or extending the refrigerant pipes (assembly pipe) Step 2.8 Fixing the installation plate Outdoor Unit Installation Step 3.1 Fixing the outdoor unit in place Step 3.3 Evacuating the air Step 3.4 Adding refrigerant Installation Inspection Step 4.1 Performing the gas leak tests Step 4.2 Running the Smart Install mode Step 4.3 Performing final check and trial operation Correct Disposal of This Product Correct disposal of batteries in this product Information Safety 4 Safety InformationInstall your appliance on a level and hard floor that can support its weight Install the drain hose properly so that water drains correctly FOR POWER SUPPLY When the circuit breaker is damaged, contact your nearest service centre 5 • Failing to do so may result in electric shock or fire•Do not use a ventilating fan •A spark may result in an explosion or fireTo reinstall the air conditioner, please contact your nearest service centre 6 •This may result in electric shock•If a child places a bag over its head, it may result in suffocationDo not touch the air flow blade with your hands or fingers during heating •This may result in electric shock or burnsDo not strike or pull the air conditionerwith excessive force •This may result in fire, injury, or problems with the product •This may result in children seriously injuring themselves • Water dripping from the indoor unit may result in fire or property damage •Failing to do so may result in injury, death or property damage •This may result in electric shock, fire, problems with the product, or injuryDo not operate the appliance with wet hands 7 •The water may be harmful to humans•This may result in burns or injury •This may result in property damage •This may result in harm to humans, animals or plants This may result in discolouration, deformation, damage, electric shock or fire •For cleaning inside the appliance, contact your nearest service centre •Failing to do so may result in damage, electric shock or fire Glance a At 8 Indoor Unit Overview9 Remote Control Overview10 Remote Control Operation12 Cooling Operation13 Dehumidifying Operation14 Quick Smart Features17 Energy-SavingOperation20 Cleaning at a Glance22 Troubleshooting24 Installation25 Power supply line, fuse, or circuit breaker26 PreparationStep1.1 Choosing the installation locationOverview of installation location requirements •Comply with the length and height limits described in the figure aboveMinimum clearances for the outdoor unit (6 cases) 27 Step1.3 Checking and preparing accessories and tools28 Optional accessoriesAccessories in the outdoor unit package General tools •Vacuum pump (Backward flowing prevention) •Manifold gauge •Stud finder •Torque wrench •Pipe cutter •Reamer •Pipe bender •Spirit level •Screwdriver •Spanner •Drill •L-wrench •Measuring tape Tools for test operation •Thermometer •Resistance meter •Electroscope 30 Indoor Unit Installation•Tighten the terminal block screw to 1.2-1.8N•m (1.2-1.8kgf•cm) •Each wire is labelled with the corresponding terminal number •Use shield cable (Category 5; less than 50pF/m) for noisy environmental site •Power & Communication cable shall not exceed 30m •If you need to extend the pipe, be sure to extend the cable, too 31 Step 2.2 Optional: Extending the power cable1Prepare the following tools •Peel off 20 mm of cable shields from the pre-installedtube • The compression dimension should be Three or more layers of insulation are required 6Apply heat to the contraction tube to contract it 3Insert both sides of core wire of the power cable into the connection sleeve •Method 1: Push the core wire into the sleeve from both sides •Method 2: Twist the wire cores together and push it into the sleeve •Make sure that the connection parts are not exposed to outside 32 •In case of extending the electric wire, please DO NOT use a round-shapedpressing socket or a fire Step 2.3 Installing and connecting the drain hose 1Install the drain hose 2Pour water into the drain pan. Check whether the hose is well drained •Inadequate installation may cause water leakage •Do not box in or cover the drain hose connection Drain hose connection must be easily accessible and serviceable Step 2.4 Optional: Extending the drain hose 34 Cut out the appropriate2Smooth the cut edges 4Cut off the remaining foam insulation •The pipe should not project from the rear of the indoor unit 6Pass the pipe through the hole in the wallStep 2.7 Shortening or extending the refrigerant pipes (assembly pipe) •Do not box in or cover the pipe connection All refrigerant pipe connection must be easily accessible and serviceable 35 Step 2.8 Fixing the installation plateYou can install the indoor unit on a wall, window frame, or gypsum boardWhen fixing the indoor unit on a wall Tighten the flare nut at the specified torque. If the flare nut isWhen fixing the indoor unit on a window frame 3Attach the installation plate to the wooden upright using tapping screws 36 1Use stud finder to find out locations of the studs2Fix the plate hanger on two studs •Fix the installation plate without inclining to one side 37 Outdoor Unit InstallationStep 3.1 Fixing the outdoor unit in place 38 Step 3.3 Evacuating the airof cooling capacity and malfunction. Use a vacuum pump •When installing, make sure there is no leakage 1Leave the system in the standby mode 39 3Open the valve of the low pressure side of manifold gauge anticlockwise•Close the valve of the low pressure side of manifold gauge clockwise •Turn off the vacuum pump •Check for 2 minutes if there is any pressure change •Remove the hose of the low pressure side of manifold gauge 5Set a valve cork of liquid and gas service port to the open position Step 3.4 Adding refrigerant Refer to the Service Manual for further details refrigerant: 40 Installation Inspection41 ❈: Off, : Blinking, : On42 Step 4.3 Performing final check and trial operation1Check the following: •Strength of the installation site •Tightness of pipe connection to detect gas leak •Electric wiring connection •Heat-resistantinsulation of the pipe •Drainage •Grounding conductor connection •Correct operation (Take the following steps.) 2Press the (Power) button on the remote control to check the following: •The indicator on the indoor unit lights up •The airflow blade opens and the fan gears up for operation •In Cool mode, use the Temperature button to set the set temperature to 20 °C 5Press the (Power) button to stop the trial operationPumping down for removing the product WARNING 2Let the compressor run for more than 5 minutes 3Release the valve caps on High and Low pressure side 4Use L-wrenchto close the valve on the high pressure side 5After approximately1 minute, close the valve on the low pressure side 6Stop operation of the air conditioner by pressing the (Power) button on the indoor unit or remote control 7Disconnect the pipes CAUTION 45 QUESTIONS OR COMMENTSDB68-07847A-00
Also you can find more Samsung manuals or manuals for other Household Appliance.