White Rodgers 1311 manuals
Household Appliance > Thermostat
When we buy new device such as White Rodgers 1311 we often through away most of the documentation but the warranty.
Very often issues with White Rodgers 1311 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Thermostat White Rodgers 1311 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Thermostat on our side using links below.
White Rodgers 1311 Installation Instructions
8 pages 389.74 Kb
Operator: Save these instructions for future use! INSTALLA TION INSTRUCTIONS PRECAUTIONS TYPE 1311 WHITE-RODGERS(3 WIRE) SPECIFICATIONSAll guarantees are void if these specifications are exceeded. PRINCIPLE OF OPERATION 2 PRINCIPLE OF OPERATION (Continued)PIPING INSTALLATIONCAUTION !To prevent injuries from scalding always drain system before unlatching valve assembly from body. 3 {}2" MINIMUM CLEARANCE VALVE HEAD STEM BODY Fig. 5 DIAGRAM FOR SYSTEMS WHERE BURNER AND CIRCULATOR OPERATION IS INDEPENDENT OF THERMOSTATFig. 6 Using Type 1311 Zone Valve Alternate Wiring for using 750 Mv. Gas Valve For Type 8A02A Relay Fig. 7 Diagram for Oil-fired System using 8A03A-2 Fig. 7a Diagram for Gas-Fired System Clearances required for assembling valve head to valve body. DIAGRAM FOR SYSTEMS WHERE INTERNAL TRANSFORMER OF RELAY CONTROL SUPPLIES POWER FOR ZONE VALVES WIRING 4 }For Type 809A Relay For Type 692 or 693 For Type 6C92 or 6C93 For Type 8B42A or 8B43A For Type 8F43A MANUAL OPERATIONOPEN Fig. 10 For Type 8F42A }V1 1 V2 C1 C2 T1 2 T2 Z B V3 W DIAGRAM FOR SYSTEMS WHERE EXTERNAL TRANSFORMER REQUIRED FOR POWERING ZONEFig. 8 Diagram for Gas-Fired System using 842A-16 WIRING Continuedpower is resumed, valve will automatically return to command of room thermostat. For Type 829A Relay Fig. 9 Diagram for Gas-Fired System using 842A-1 or 843A-1 INSTRUCTIONS DINSTALLA TION 5 TYPE 1311PRCAUTIONSROBINETS DE ZONE HYDRONIQUES PRINCIPE DE FONCTIONNEMENT DESCRIPTION SPCIFICATIONS WHITE-RODGERS 7 {Cblage permettant dutiliser un robinet gaz de 750mV Fig. 7 Schma pour un systme aliment mazout et dot dun 8A03A-2 Fig. 7a Schma pour un systme aliment gaz Dgagement requis pour monter la tte au corps du robinet. TTE DU ROBINET DGAGEMENT MINIMUM DE 2" DGAGEMENT MINIMUM DE 23/4" CBLAGECblage pour lutilisation avec un relais type 8A02A Cblage pour type 8F42A Cblage pour type 8F43A Fig. 10 Cblage pour type 692 ou 693 Cblage pour type 8B42A ou 8B43A 8 {Fig. 9 Schma pour un systme aliment gaz et dot dun 842A-1 ou dun 843A-1 FONCTIONNEMENT MANUEL CBLAGE (suite)Fig. 8 Schma pour un systme aliment gaz et dot dun 842A-16 Cblage pour relais de type 829A Cblage pour un relais de type 809A Cblage pour type 6C92 ou 6C93 courant rtabli, le robinet se remettra automatiquement sous la commande du thermostat dambiance.
Also you can find more White Rodgers manuals or manuals for other Household Appliance.