WIRING – Continued

DIAGRAM FOR SYSTEMS WHERE INTERNAL TRANSFORMER OF RELAY-HOT WATER CONTROL SUPPLIES POWER FOR ZONE VALVES

 

4

 

4

 

4

 

4

 

4

6

5

6

5

6

5

6

5

6

5

2

2

5

4

2

2

5

4

2

2

5

4

2

2

5

4

2

2

5

4

6

 

1

3

6

 

1

3

6

 

1

3

6

 

1

3

6

 

1

3

TO LOW VOLTAGE

GAS VALVE

 

 

TYPE 842A-16

T3

 

 

T1

 

HOT

 

V1

T2

LINE

 

 

V2

N

1 2

C1 C2

 

 

 

 

3

 

 

 

TYPE 8F43A

 

3

 

ADDITIONAL

 

 

 

 

CIRCULATOR

 

 

 

TO ZONE

ZONES

 

TYPE 8F42A

 

 

 

 

 

 

 

 

 

 

TO ZONE

MOTOR

 

 

 

5

VALVES

 

 

 

 

 

 

T2

 

 

 

 

 

 

 

 

 

 

 

 

 

5

VALVES

 

 

T1

}

 

 

 

T2

T1

}1

 

 

Z

 

 

 

Z

 

N

 

 

V1

1

 

 

N

 

V1

 

 

 

 

V2

 

 

 

 

V2

 

 

LINE

1

 

 

 

 

 

LINE

 

TO 24 VAC

 

 

 

TO 24 VAC

 

Fig. 8 Diagram for Gas-Fired

 

V3

HOT

2

 

 

1

 

GAS VALVE

 

 

GAS VALVE

 

2

 

 

 

 

 

System using 842A-16

HOT

B

 

 

 

C1

C2

 

 

 

 

 

 

 

 

 

 

 

C1

C2

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alternate Connections

 

 

Alternate Connections

 

 

 

 

For Type 8F43A

 

 

 

For Type 8F42A

 

 

 

 

 

 

 

 

 

CIRCULATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CIRCULATOR

 

 

 

 

MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

 

 

 

 

DIAGRAM FOR SYSTEMS WHERE EXTERNAL TRANSFORMER REQUIRED FOR POWERING ZONE

 

4

 

4

 

4

 

4

 

4

6

5

6

5

6

5

6

5

6

5

2

2

5

4

2

2

5

4

2

2

5

4

2

2

5

4

2

2

5

4

6

 

1

3

6

 

1

3

6

 

1

3

6

 

1

3

6

 

1

3

ADDITIONAL

ZONES

TRANSFORMER

 

 

 

TO ZONE

2

 

 

 

 

 

{3

 

 

 

 

 

VALVES

 

 

 

 

 

 

TYPE 8B42A

 

TYPE 842A OR

 

 

 

OR 8B43A

 

 

 

 

 

 

843A

 

 

 

 

 

 

 

 

 

 

T2

T1

T1

 

 

N

 

 

 

 

 

LINE

 

 

 

 

 

HOT

 

 

 

T2

 

 

 

 

 

 

LINE

HOT

1

2

 

 

 

 

 

 

 

 

 

1

2

N

 

C1

C2

 

C1

 

C2

 

B1

B2

 

 

 

 

 

 

B1

 

B2

 

 

 

 

 

 

 

 

 

 

IGN.

 

 

 

 

 

TRANS.

 

 

 

CIRCULATOR

 

 

CIRCULATOR

 

 

MOTOR

BURNER

BURNER

 

 

 

MOTOR

 

 

 

MOTOR

 

CONTROL

 

 

 

 

 

 

 

 

 

Alternate Connections

For Type 8B42A or 8B43A

Fig. 9 Diagram for Gas-Fired System using 842A-1 or 843A-1

 

 

 

 

 

TYPE 956

 

 

 

 

 

 

 

FLAME DETECTOR

 

 

 

 

 

 

 

 

TYPE 692 OR 693

 

 

 

 

 

 

 

 

OIL BURNER

 

 

 

 

 

 

 

 

HOT WATER CONTROL

2

TYPE 809 RELAY

 

 

 

 

TO ZONE

 

 

 

 

VALVES {3

 

 

 

 

 

FD

 

 

 

 

 

 

2

FD

 

 

HOT

2

 

 

 

 

 

 

LINE

 

 

 

TO ZONE

T

 

 

TO ZONE

 

 

 

VALVES {3

 

 

 

VALVES {3

 

 

 

T

1

2

N

 

 

 

 

HOT

 

C1

C2

 

 

 

 

 

 

 

 

 

1

2

L

L

LINE

 

B1

B2

 

N

 

 

IGN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANS.

 

TO GAS VALVE

 

 

 

 

CIRCULATOR

 

 

 

AND TRANSFORMER

 

 

 

 

 

 

 

 

CIRCULATOR

MOTOR

 

 

 

OR OIL BURNER

 

 

 

 

BURNER

 

 

 

 

 

 

 

CONTROL

 

 

 

MOTOR

 

 

 

 

 

 

 

 

MOTOR

 

Alternate Connections

Alternate Connections

For Type 809A Relay

For Type 692 or 693

 

TYPE 956

 

 

 

 

 

 

 

FLAME DETECTOR

 

 

 

 

 

 

 

TYPE 6C92 OR 6C93

 

 

 

 

 

 

 

OIL BURNER

 

 

 

 

 

 

HOT WATER CONTROL

 

 

Alternate Connections

 

 

 

 

 

 

T

 

 

HOT

For Type 829A Relay

 

FD

 

 

 

 

 

 

 

 

LINE

TYPE 829A RELAY

 

 

 

 

 

1

2

 

N

 

 

 

 

 

 

C1

C2

 

2

 

 

THERM

 

 

 

 

 

 

 

 

B1

B2

TO ZONE

 

 

 

 

VALVES {3

 

 

 

 

 

IGN.

 

 

 

 

 

TRANS.

 

 

5

 

 

HOT

 

 

 

 

3

1

 

 

 

 

 

LINE

 

 

 

 

 

 

 

 

 

 

 

6

4

2

N

CIRCULATOR

 

 

 

 

 

 

 

MOTOR

BURNER

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

Alternate Connections

 

TRANSFORMER OR

 

 

 

 

 

 

TO GAS VALVE AND

 

 

For Type 6C92 or 6C93

 

OIL BURNER

 

CIRCULATOR

 

 

CONTROL

 

MOTOR

 

MANUAL OPERATION

Use manual operator only in case of power failure, or for testing system prior to wiring. If power fails, valve may be in either “Open” or “Closed” position.

If in “Open” position, valve will remain open until power is resumed.

power is resumed, valve will automatically return to command of room thermostat.

OPEN

If in “Closed” position, valve may be opened by turning dial

 

 

clockwise with your thumb until word “Open” appears. When

4

Fig. 10

 

 

 

Page 4
Image 4
White Rodgers 1311 installation instructions Wiring, Manual Operation

1311 specifications

The White Rodgers 1311 is a versatile and efficient thermostat designed to optimize the heating and cooling systems in residential settings. Known for its reliable performance and user-friendly features, the 1311 caters to various types of HVAC systems, including gas and electric furnaces, heat pumps, and conventional air conditioning units.

One of the standout features of the White Rodgers 1311 is its programmable capabilities, allowing users to set specific heating and cooling schedules for different times of the day. This programmability enables homeowners to achieve optimal comfort while maximizing energy efficiency. The thermostat allows for multiple program settings, meaning users can customize their environment according to their daily routines and preferences.

Another key characteristic of the 1311 is its digital display, which provides clear and easy-to-read information about the current temperature, set points, and operating status. The straightforward interface simplifies the thermostat's operation, making it accessible even for those who may not be technologically savvy. The backlit display further enhances visibility, allowing users to adjust settings even in low-light conditions.

The White Rodgers 1311 also supports advanced temperature control technologies. It employs a precision temperature sensor that ensures accurate readings, helping to maintain the chosen ambient temperature with minimal fluctuations. This accuracy translates to increased comfort and can contribute to reduced energy consumption, resulting in lower utility bills.

Integrating seamlessly with most HVAC systems, the 1311 features compatibility with multi-stage heating and cooling systems, providing flexibility for various home setups. Its design includes built-in features to protect the system from short cycling—where the system turns on and off too frequently—thereby prolonging the lifespan of the HVAC equipment.

Additionally, the thermostat is equipped with simple maintenance reminders and alerts, prompting homeowners to change filters or schedule service when needed. This proactive approach to system upkeep helps maintain efficiency and performance over time.

In summary, the White Rodgers 1311 thermostat combines ease of use with advanced features and reliable performance. Its programmability, accurate temperature control, multi-system compatibility, and user-friendly interface make it an excellent choice for homeowners seeking to enhance their comfort while optimizing energy consumption.