York D1EE036 manuals
Household Appliance > Air Conditioner
When we buy new device such as York D1EE036 we often through away most of the documentation but the warranty.
Very often issues with York D1EE036 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Air Conditioner York D1EE036 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Air Conditioner on our side using links below.
32 pages 2.75 Mb
TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. 2 TABLE OF CONTENTSLIST OF FIGURES LIST OF TABLES 3 DESCRIPTIONFEATURES 4 FACTORY-INSTALLED OPTIONSFIELD-INSTALLED ACCESSORIES5 FIGURE 1 - SUNLINE PLUS COMPONENT LOCATION036-21411-002-A-0204 Not ARI required 6 TABLE 1: CAPACITY RATINGS - COOLING / ELECTRIC HEATINGTABLE 2: CAPACITY RATINGS - COOLING / GAS HEATING T ABLE 3: SOUND POWER RA TIN GS 7 TABLE 4: PHYSICAL DATA - BASIC UNIT8 TABLE 5: COOLING CAPACITIES - 3 TON (DEE / DEG036)motor power input is 0.36kW. Refer to Table 8 or 11 for the kW of the supply air blower motor. Unitary Products Group 9 9 TABLE 6: COOLING CAPACITIES - 4 TON (DEE / DEG048)motor power input is 0.36kW. Refer to Tables 9 or 11 for the kW of the supply air blower motor. 10 Unitary Products Group 10 TABLE 7: COOLING CAPACITIES - 5 TON (DEE / DEG060)motor power input is 0.36kW. Refer to Tables 10 or 11 for the kW of the supply air blower motor. 036-21411-002-A-0204Unitary Products Group 11 11 TABLE 8: SUPPLY AIR BLOWER PERFORMANCE -DEE/DEG036 W/ BELT DRIVE & SIDE DUCT1 212 Unitary Products Group 12 TABLE 9: SUPPLY AIR BLOWER PERFORMANCE -DEE/DEG048 W/ BELT DRIVE & SIDE DUCT1 2Unitary Products Group 13 13 TABLE 10: SUPPLY AIR BLOWER PERFORMANCE -DEE/DEG060 W/ BELT DRIVE & SIDE DUCT1 2036-21411-002-A-020414 Unitary Products Group 14 T ABLE 1 1: SUPPL Y AIR BLOWER PE RFORMANCE - D EE/DEG036-060 W/ DIRE CT DRIVE and 11). ues on applications other than gas / electric units with side duct airflows. TABLE 12: STATIC RESISTANCESduct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Unitary Products Group 15 15 TABLE 13: MOTOR AND DRIVE DATA - BELT-DRIVE BLOWERtor because they are located in the moving air, upstream of any heating device. TABLE 14: BASIC UNIT W/ DIRECT-DRIVE ELECTRICAL DATA16 Unitary Products Group 16 TABLE 15: BASIC UNIT W/ BELT-DRIVE ELECTRICAL DATAUnitary Products Group 17 17 TABLE 16: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ DIRECT DRIVE DEE036block accessories are available for field installation (see Table 19). 18 Unitary Products Group 18 TABLE 17: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ DIRECT DRIVE DEE048block accessories are available for field installation (see Table 19). TABLE 18: ELECTRIC HEAT CORRECTION FACTORS TABLE 19: FUSE BLOCK ACCESSORYUnitary Products Group 19 19 TABLE 20: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ DIRECT DRIVE DEE060block accessories are available for field installation (see Table 19). 036-21411-002-A-020420 Unitary Products Group 20 TABLE 21: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ BELT DRIVE DEE036 & 048fuse block accessories available for field installation. 036-21411-002-A-0204Unitary Products Group 21 21 TABLE 22: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ BELT DRIVE DEE060fuse block accessories available for field installation. 22 FIGURE 2 - POWER SUPPLY, POWER WIRING SINGLE PHASEFIGURE 3 - POWER SUPPLY, POWER WIRING THREE PHASE FIGURE 4 - CONTROL WIRING - COOLING ONLY FIGURE 5 - CONTROL WIRING- COOLING & HEATING MULTI-STAGE FIGURE 6 - CONTROL WIRING - COOLING/ HEATING (24 VOLT THERMOSTAT)T O R E M O T E S E N S O R 2 T H 0 4 0 7 0 2 2 2 4 I F U S E D A D D J U M P E R E L E C T R I C H E A T E R . C O O L I N G / H E A T I N G ( 2 4 V O L T T H E R M O S T A T ) 23 FIGURE 7 - CONTROL WIRING - COOLING/HEATING (ELECTRONIC THERMOSTAT)T H E R M O S T A T 1 9 - 3 / 4 FIGURE 8 - UNIT DIMENSIONS WITH ECONOMIZER RAINHOODA D D J U M P E R T E R M I N A L S U N I T T E R M I N A L S T R I P T B 1 2 4 V O L T T R A N S F O R M E R 2 7 - 1 / 2 1 - 5 / 8 2 7 - 1 / 2 1 9 - 1 / 2 4 4 - 7 / 8 24 FIGURE 9 - UNIT DIMENSIONS DEE 3, 4, & 5 TON24 Unitary Products Group TABLE 23: UTILITIES ENTRY DATA FIGURE 10 -ACCESS PANELS AND DISCONNECTthe slice in the insulation. 25 FIGURE 11 -UNIT DIMENSIONS DEG 3, 4, & 5 TONTABLE 24: DEE/DEG UNIT CLEARANCES 26 FIGURE 12 -DEE/DEG DIMENSIONS REAR VIEW - 3, 4, & 5 TON27 FIGURE 13 -DETAIL B UNIT DIMENSIONS WITH DAMPER/RAINHOODFIGURE 14 -UNIT & CURB APPLICATION 28 FIGURE 15 -ROOF CURB DIMENSIONS DEE & DEG 3, 4, & 5 TON TABLE 25: UNIT WEIGHTSFIGURE 16 -CENTER OF GRAVITY TABLE 26: ACCESSORYS WEIGHT 30 MECHANICAL SPECIFICATIONSGENERAL DESCRIPTION UNIT CABINET INDOOR (EVAPORATOR) FAN ASSEMBLY OUTDOOR (CONDENSER) FAN ASSEMBLY REFRIGERANT COMPONENTS 31 GAS HEATING SECTION (DEG MODELS)ELECTRIC HEATING SECTION (DEE MODELS) UNIT OPERATING CHARACTERISTICS ELECTRICAL REQUIREMENTS STANDARD LIMITED WARRANTIES 32 OPTIONAL OUTDOOR AIROTHER PRE-ENGINEERED ACCESSORIES AVAIL- ABLE OTHER FACTORY INSTALLED OPTIONS
Also you can find more York manuals or manuals for other Household Appliance.