York D1EG COOLING CAPACITIES - 4 TON DEE / DEG048, 036-21411-002-A-0204, Unitary Products Group

Models: D1EG D1EE036

1 32
Download 32 pages 59.56 Kb
Page 9
Image 9
TABLE 6: COOLING CAPACITIES - 4 TON (DEE / DEG048)

036-21411-002-A-0204

TABLE 6: COOLING CAPACITIES - 4 TON (DEE / DEG048)

AIR ON

 

 

 

 

 

 

TEMPERATURE OF AIR ON CONDENSER COIL

 

 

 

 

 

 

 

 

 

 

 

85°F

 

 

 

 

 

 

 

 

 

95°F

 

 

 

 

 

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSIBLE CAPACITY1, MBH

 

 

 

 

 

SENSIBLE CAPACITY1, MBH

 

COIL

 

TOTAL

POWER

 

 

TOTAL

POWER

 

 

 

 

 

ENTERING DRY BULB, °F

 

 

 

ENTERING DRY BULB, °F

 

 

 

 

CAP.1

INPUT2

 

 

CAP.1

INPUT2

 

 

 

CFM

 

WB

MBH

kW

86

83

 

80

77

74

71

68

MBH

kW.

 

86

83

 

80

77

74

71

68

 

 

°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

64

3.9

45

39

 

33

27

21

-

-

60

4.2

 

44

38

 

32

26

20

-

-

2000

 

67

57

3.8

55

49

 

43

37

31

25

19

53

4.1

 

53

47

 

41

35

29

23

17

 

62

54

3.8

54

54

 

53

47

41

35

29

50

4.0

 

50

50

 

50

44

38

32

26

 

 

 

 

 

 

 

57

54

3.8

54

54

 

54

48

42

36

30

50

4.0

 

50

50

 

50

46

40

34

28

 

 

72

62

3.9

42

36

 

31

25

20

-

-

58

4.2

 

41

35

 

30

24

19

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

67

55

3.8

51

46

 

40

35

30

24

19

52

4.1

 

50

44

 

39

34

28

23

18

 

 

62

52

3.8

52

52

 

49

44

39

33

28

49

4.1

 

49

49

 

47

42

37

31

26

 

 

57

52

3.8

52

52

 

51

45

40

35

29

49

4.1

 

49

49

 

49

44

38

33

27

 

 

72

59

3.9

38

33

 

29

24

19

-

-

57

4.2

 

38

33

 

28

23

18

-

-

1600

 

67

54

3.8

48

43

 

38

33

29

24

19

52

4.2

 

47

42

 

37

32

28

23

18

 

 

62

50

3.7

50

50

 

46

41

36

32

27

47

4.1

 

47

47

 

45

40

35

31

26

 

 

57

50

3.7

50

50

 

47

42

38

33

28

47

4.1

 

47

47

 

46

41

37

32

27

 

 

72

58

3.8

35

31

 

27

23

18

-

-

55

4.2

 

34

30

 

26

22

17

-

-

1400

 

67

52

3.8

44

39

 

35

31

27

22

18

49

4.2

 

42

38

 

34

30

26

21

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

49

3.7

48

47

 

43

39

34

30

26

46

4.1

 

46

45

 

42

37

33

29

25

 

 

57

49

3.7

49

48

 

44

40

36

31

27

46

4.1

 

46

46

 

43

38

34

30

26

 

 

72

57

3.8

32

29

 

25

21

17

-

-

53

4.2

 

31

28

 

24

20

16

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

67

50

3.8

40

36

 

32

29

25

21

17

47

4.2

 

38

35

 

31

27

23

20

16

 

 

62

48

3.7

47

44

 

40

36

33

29

25

45

4.1

 

45

42

 

38

34

31

27

23

 

 

57

48

3.7

48

45

 

41

37

34

30

26

45

4.1

 

45

43

 

39

35

32

28

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR ON

 

 

 

 

 

 

TEMPERATURE OF AIR ON CONDENSER COIL

 

 

 

 

 

 

 

 

 

 

 

105°F

 

 

 

 

 

 

 

 

 

115°F

 

 

 

 

 

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSIBLE CAPACITY1, MBH

 

 

 

 

 

SENSIBLE CAPACITY1, MBH

 

COIL

 

TOTAL

POWER

 

 

TOTAL

POWER

 

 

 

 

 

ENTERING DRY BULB, °F

 

 

 

ENTERING DRY BULB, °F

 

 

 

 

CAP.1

INPUT2

 

 

CAP.1

INPUT2

 

 

 

CFM

 

WB

MBH

kW.

86

83

 

80

77

74

71

68

MBH

kW.

 

86

83

 

80

77

74

71

68

 

 

°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

56

4.7

42

36

 

30

25

19

-

-

53

5.2

 

41

35

 

29

23

17

-

-

2000

 

67

50

4.6

50

45

 

39

33

28

22

16

47

5.1

 

47

44

 

38

32

26

20

14

 

62

47

4.5

47

47

 

47

41

35

29

23

44

5.0

 

44

44

 

44

38

32

26

20

 

 

 

 

 

 

 

57

47

4.5

47

47

 

47

44

38

32

26

44

5.0

 

44

44

 

44

42

36

30

24

 

 

72

54

4.7

39

34

 

29

23

17

-

-

51

5.1

 

38

33

 

27

22

17

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

67

49

4.6

47

43

 

37

32

27

21

16

46

5.1

 

45

41

 

36

31

25

20

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

46

4.5

46

46

 

45

40

34

29

23

43

5.0

 

43

43

 

43

37

32

26

21

 

 

57

46

4.5

46

46

 

46

42

36

31

26

43

5.0

 

43

43

 

43

40

34

29

24

 

 

72

53

4.7

36

31

 

27

22

17

-

-

49

5.1

 

35

30

 

25

21

16

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1600

 

67

48

4.6

45

40

 

35

31

26

21

16

44

5.1

 

43

39

 

34

29

24

19

15

 

 

62

44

4.6

44

44

 

43

38

33

29

24

41

5.0

 

41

41

 

41

36

31

26

22

 

 

57

44

4.5

44

44

 

44

39

34

30

25

41

5.0

 

41

41

 

41

37

32

28

23

 

 

72

51

4.7

33

29

 

25

21

16

-

-

48

5.1

 

32

28

 

24

20

15

-

-

1400

 

67

46

4.6

41

37

 

33

28

24

20

16

43

5.0

 

40

35

 

31

27

23

19

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

43

4.5

43

42

 

40

36

31

27

23

40

5.0

 

40

40

 

38

34

30

25

21

 

 

57

43

4.5

43

43

 

41

37

32

28

24

40

5.0

 

40

40

 

39

35

31

26

22

 

 

72

50

4.7

30

27

 

23

19

16

-

-

47

5.1

 

30

26

 

22

18

15

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

67

44

4.6

37

33

 

30

26

22

19

15

42

5.0

 

36

32

 

29

25

21

18

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

42

4.5

42

41

 

37

33

29

26

22

39

5.0

 

39

39

 

35

32

28

24

21

 

 

57

42

4.5

42

41

 

38

34

30

27

23

39

5.0

 

39

39

 

36

33

29

25

22

1.These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from Table 9 or 11, multiply this value by 3.425 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.

2.These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36kW. Refer to Tables 9 or 11 for the kW of the supply air blower motor.

NOMINAL RATING

ALL SENSIBLE CAPACITY

Unitary Products Group

9

Page 9
Image 9
York D1EG, D1EE036 warranty COOLING CAPACITIES - 4 TON DEE / DEG048, 036-21411-002-A-0204, Unitary Products Group