Product specication and feature
2-26
2.2.4.4 Scan
1) Pictorial signal input part: output signal of CIS passes through MP Cap change to ADC at LAFE1001, and
dened signal between LAFE1001 and JUPITER5 processes the Image signal. When AFE accepts each
pixel, CDS (Correlated Double Sampling ) technique which samples arm-level twice is used on each pixel
by the CIS signal.
2) The image processing portion is read by CIS Pixel data in 1200dpi Line and processed using an Error
Diffusion Algorithm on Text mode and Photo mode. When scanning at machine and/or on PC Scan, the
data is stored in a Scan Buffer without algorithm.
Shading and Gamma Correction are executed immediately in every mode, then processing is executed
later.
* Scan Image Control Specication
Minimum Scan Line Time : 0.75ms(300dpi)
Scan Resolution : Max. 1200DPI
Scan Width : 216mm
main function
- Internal 10bit ADC
- White Shading Correction
- Gamma Correction
- CIS Interface
- 256 Gray Scale
3) CIS Operating Part : CISM Image sensor use +3.3V and LEDs uses +12V
- CIS Maximum Operating Frequency : 4MHz
- CIS Line time : 0.75ms
- White Data output Voltage : 1.0Vmin (Color mode : 300dpi, 0.75ms/line)
- Maximum LED Current : 45~60 mA Max.( +12V)