Rack-mounting the EPS

21

Rack-mounting the

The EPS is 1.5U high (1 U equals 3.8 cm (1.5 inches)) and fits in most

EPS

standard 19-inch equipment racks.

 

CAUTIONS:

 

Before you connect the brackets or mount the unit in the rack,

 

disconnect all cables and power from the EPS.

 

Verify that no self-adhesive pads are attached to the underside of the

 

unit.

 

1 Place the EPS upright on a hard, flat surface with the front facing you.

 

2 Place a mounting bracket over the mounting holes on one side of the

 

unit, as shown in Figure 6.

 

Figure 6 Fitting a Bracket for Rack Mounting

3Insert the three screws and tighten with a suitable screwdriver (not provided).

You must use the screws supplied with the mounting brackets. Damage to the unit caused by using incorrect screws invalidates your warranty.

4Repeat step 2 and step 3 for the other side of the EPS.

5Insert the EPS into the 19-inch rack and secure it with suitable screws (not provided). Ensure that nothing obstructs the ventilation holes.

6Connect the network cabling.