3Com 5101T-FB-SMA, 5101T-FB-FC, 5101T-FB-ST manual SQE Test, High Power PWR

Models: 5101T-FB-ST 5101T-FB-SMA 5101T-FB-FC

1 52
Download 52 pages 48.45 Kb
Page 18
Image 18

SQE Test

When enabled, the collision detection capability of the transceiver is tested after each transmis- sion. If the test is successful, the SQE test (Signal Quality Error test, or heartbeat) signal is sent on the AUI to the attached controller. The default setting is enabled.

When disabled, this test is not performed and no SQE test signal is sent to the AUI. Always disable this function when connecting to an IEEE 802.3 repeater.

High Power (PWR)

When enabled, the optical power output on the main link is in the High range. The default setting is disabled, which invokes the optical power output on the main link in the Normal range.