Also, ensure that you have accounted for the distance reduction caused by external baseband repeaters that were added and by baseband segments connected to those repeaters.

Miscellaneous Errors

Many types of physical layer errors can occur if the controller AUI interface is Ethernet Version

1.0or not fully compliant with Version 2.0 and IEEE 802.3.

If errors occur:

1.Try switching between the Full Step and Half Step options on the 10BASE-FB Transceiver.

2.Verify that an IEEE 802.3 AUI cable is being used with 802.3 controllers

3.Verify that Ethernet V2.0 cables are being used with Ethernet V2.0 controllers.

Refer to the next section for more information on AUI cables.