Dell 7.4 manual Error occurred %1

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 157
Image 157

SNMP Trap

1203

Numbers

 

Event ID — 2345

Description

The virtual disk initialization failed.

Severity

Critical / Failure / Error

Cause and

Cause: The controller cannot communicate with attached devices. A disk may be

Action

removed or contain errors. Cables may also be loose or defective.

 

Action: Verify the health of attached devices. Review the Alert Log for significant

 

events. Make sure the cables are attached securely. See the Cables Attached

 

Correctly section for more information on checking the cables.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2081

SNMP Trap

1204

Numbers

 

Event ID — 2346

Description

Error occurred: %1.

Severity

Warning / Non-critical

Cause and

Cause: A physical device may have an error. The %1 indicates a substitution

Action

variable. The text for this substitution variable is generated by the firmware and is

 

displayed with the alert in the alert log. This text can vary depending on the

 

situation.

 

Action: Verify the health of attached devices. Review the alert log for significant

 

events. Run the PHY integrity diagnostic tests. You may need to replace faulty

 

hardware. Make sure that the cables are attached securely. See the hardware

 

documentation for more information.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2048, 2050, 2056, 2057, 2076, 2079, 2081, 2083, 2095,

 

2129, 2201, 2203, 2270, 2282, 2369

 

Local Response Agent (LRA) Number: 2070

SNMP Trap

903

Numbers

 

Event ID — 2347

Description

The rebuild failed due to errors on the source physical disk.

Severity

Critical / Failure / Error

157