Dell 7.4 manual Discharged

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 154
Image 154

Related Alert Information

SNMP Trap Numbers

Storage Management was not running. This text can vary depending on the situation.

Action: See the hardware documentation for more information.

Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: 2061

754

Event ID — 2337

Description

The controller is unable to recover cached data from the battery backup unit (BBU).

Severity

Critical / Failure / Error

Cause and

Cause: The controller was unable to recover data from the cache. This may occur

Action

when the system is without power for an extended period when the battery is

 

discharged.

 

Action: Check if the battery is charged and in good health. When the battery

 

charge is unacceptably low, it cannot maintain cached data. Check if the battery

 

has reached its recharge limit. The battery may need to be recharged or replaced.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2101

SNMP Trap

1154

Numbers

 

Event ID — 2338

Description

The controller has recovered cached data from the BBU.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1151

Numbers

 

Event ID — 2339

Description

The factory default settings have been restored.

154

Page 154
Image 154
Dell 7.4 manual Discharged