Related Alert Information
SNMP Trap Numbers
Storage Management was not running. This text can vary depending on the situation.
Action: See the hardware documentation for more information.
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
754
Event ID — 2337
Description | The controller is unable to recover cached data from the battery backup unit (BBU). |
Severity | Critical / Failure / Error |
Cause and | Cause: The controller was unable to recover data from the cache. This may occur |
Action | when the system is without power for an extended period when the battery is |
| discharged. |
| Action: Check if the battery is charged and in good health. When the battery |
| charge is unacceptably low, it cannot maintain cached data. Check if the battery |
| has reached its recharge limit. The battery may need to be recharged or replaced. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: 2101 |
SNMP Trap | 1154 |
Numbers |
|
Event ID — 2338 | |
Description | The controller has recovered cached data from the BBU. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert is for informational purposes. |
Action | Action: None |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1151 |
Numbers |
|
Event ID — 2339 | |
Description | The factory default settings have been restored. |
154