Event ID — 2064

Description

Virtual disk rebuild started.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None

Related Alert

Clear Alert Number: 2091

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1201

Numbers

 

Event ID — 2065

Description

Physical disk rebuild started.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None

Related Alert

Clear Alert Number: 2092

Information

Related Alert Number: 2099, 2121, 2196

 

Local Response Agent (LRA) Number: None

SNMP Trap

901

Numbers

 

Event ID — 2067

Description

Virtual disk check consistency cancelled.

Severity

OK / Normal / Informational

Cause and

Cause: The check consistency operation was cancelled because a physical disk in

Action

the array has failed or because a user cancelled the check consistency operation.

 

Action: If the physical disk failed, then replace the physical disk. You can identify

 

which disk failed by locating the disk that has a red “X” for its status. Perform a

 

rescan after replacing the disk. The consistency check can take a long time. The

 

time it takes depends on the size of the physical disk or the virtual disk.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

Local Response Agent (LRA) Number: None

64

Page 64
Image 64
Dell 7.4 manual Virtual disk rebuild started