Event ID — 2064
Description | Virtual disk rebuild started. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert is for informational purposes. |
Action | Action: None |
Related Alert | Clear Alert Number: 2091 |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1201 |
Numbers |
|
Event ID — 2065 | |
Description | Physical disk rebuild started. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert is for informational purposes. |
Action | Action: None |
Related Alert | Clear Alert Number: 2092 |
Information | Related Alert Number: 2099, 2121, 2196 |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 901 |
Numbers |
|
Event ID — 2067 | |
Description | Virtual disk check consistency cancelled. |
Severity | OK / Normal / Informational |
Cause and | Cause: The check consistency operation was cancelled because a physical disk in |
Action | the array has failed or because a user cancelled the check consistency operation. |
| Action: If the physical disk failed, then replace the physical disk. You can identify |
| which disk failed by locating the disk that has a red “X” for its status. Perform a |
| rescan after replacing the disk. The consistency check can take a long time. The |
| time it takes depends on the size of the physical disk or the virtual disk. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
Local Response Agent (LRA) Number: None