Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2060

 

Local Response Agent (LRA) Number: None

SNMP Trap

901

Numbers

 

Event ID — 2185

Description

Physical disk Replace Member Operation stopped for spare.

Severity

Warning / Non-critical

Cause and

Cause: This alert is provided for informational purposes.

Action

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2060

 

Local Response Agent (LRA) Number: None

SNMP Trap

903

Numbers

 

Event ID — 2186

Description

The controller cache has been discarded.

Severity

Warning / Non-critical

Cause and

Cause: The controller has flushed the cache and any data in the cache has been

Action

lost. This may happen if the system has memory or battery problems that cause the

 

controller to distrust the cache. Although user data may have been lost, this alert

 

does not always indicate that relevant or user data has been lost.

 

Action: Verify that the battery and memory are functioning properly.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2060

SNMP Trap

753

Numbers

 

Event ID — 2187

Description

Single-bit ECC error limit exceeded on the controller DIMM.

Severity

Warning / Non-critical

Cause and

Cause: The system memory is malfunctioning.

Action

Action: Contact technical support to replace the controller memory.

103

Page 103
Image 103
Dell 7.4 manual Physical disk Replace Member Operation stopped for spare