Event Id — 2313
Description | A power supply in the enclosure has a DC failure. |
Severity | Warning / |
Cause and | Cause: The power supply has a DC failure. |
Action | Action: Replace the power supply. |
Related Alert | Clear Alert Number: 2323 |
Information | Related Alert Number: 2122, 2333 |
| Local Response Agent (LRA) Number: 2090 |
SNMP Trap | 1003 |
Numbers |
|
Event ID — 2314 | |
Description | The initialization sequence of SAS components failed during system startup. SAS |
| management and monitoring is not possible. |
Severity
Cause and Action
Critical / Failure / Error
Cause: Storage Management is unable to monitor or manage SAS devices.
Action: Reboot the system. If problem persists, make sure you have supported versions of the drivers and firmware. Also, you may need to reinstall Storage Management or Server Administrator because of some missing installation components.
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: 2051 |
SNMP Trap | 104 |
Numbers |
|
Event Id — 2315 | |
Description | Diagnostic message %1 |
Severity | OK / Normal / Informational |
Cause and | Cause: The %1 indicates a substitution variable. The text for this substitution |
Action | variable is generated by the utility that ran the diagnostics and is displayed with the |
| alert in the alert log. This text can vary depending on the situation. This alert is for |
| informational purposes. |
| Action: None |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
146