Event Id — 2313

Description

A power supply in the enclosure has a DC failure.

Severity

Warning / Non-critical

Cause and

Cause: The power supply has a DC failure.

Action

Action: Replace the power supply.

Related Alert

Clear Alert Number: 2323

Information

Related Alert Number: 2122, 2333

 

Local Response Agent (LRA) Number: 2090

SNMP Trap

1003

Numbers

 

Event ID — 2314

Description

The initialization sequence of SAS components failed during system startup. SAS

 

management and monitoring is not possible.

Severity

Cause and Action

Critical / Failure / Error

Cause: Storage Management is unable to monitor or manage SAS devices.

Action: Reboot the system. If problem persists, make sure you have supported versions of the drivers and firmware. Also, you may need to reinstall Storage Management or Server Administrator because of some missing installation components.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2051

SNMP Trap

104

Numbers

 

Event Id — 2315

Description

Diagnostic message %1

Severity

OK / Normal / Informational

Cause and

Cause: The %1 indicates a substitution variable. The text for this substitution

Action

variable is generated by the utility that ran the diagnostics and is displayed with the

 

alert in the alert log. This text can vary depending on the situation. This alert is for

 

informational purposes.

 

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

146

Page 146
Image 146
Dell 7.4 manual Severity Cause and Action