SNMP Trap

901

Numbers

 

Event ID — 2276

Description

The dedicated hot spare is too small.

Severity

Warning / Non-critical

Cause and

Cause: The dedicated hot spare is not large enough to protect all virtual disks that

Action

reside on the disk group.

 

Action: Assign a larger disk as the dedicated hot spare.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2070

SNMP Trap

903

Numbers

 

Event ID — 2277

Description

The global hot spare is too small.

Severity

Warning / Non-critical

Cause and

Cause: The global hot spare is not large enough to protect all virtual disks that

Action

reside on the controller.

 

Action: Assign a larger disk as the global hot spare.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2070

SNMP Trap

903

Numbers

 

Event ID — 2278

Description

The controller battery charge level is below a normal threshold.

Severity

Warning

Cause and

Cause: The battery is discharging. A battery discharge is a normal activity during

Action

the battery Learn cycle. The battery Learn cycle recharges the battery. You should

 

receive alert 2179 when the recharge occurs.

Action 1: Check if the battery Learn cycle is in progress. The battery also displays the Learn state while the Learn cycle is in progress.

Action 2: If a Learn cycle is not in progress, replace the battery pack.

133

Page 133
Image 133
Dell 7.4 manual Dedicated hot spare is too small